Alexandre Mendonça Munhoz, Antonio Tejerina, Angela Garcia Ruano, Rafael Netto, Burcu Celet Ozden
{"title":"Breast Reconstruction Using Smooth, Nonmagnetic Radiofrequency Identification Port Tissue Expanders.","authors":"Alexandre Mendonça Munhoz, Antonio Tejerina, Angela Garcia Ruano, Rafael Netto, Burcu Celet Ozden","doi":"10.1097/PRS.0000000000012921","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Most breast reconstructions are implant-based and performed in 2 stages using tissue expanders (TEs). Despite widespread indications for use, conventional TEs can present limitations, especially those containing metallic or magnetic ports. A new generation of TEs that incorporates nonmetallic radiofrequency identification systems (RFID TE) has been introduced. The authors assessed outcomes and risk factors for complications after implant-based reconstruction (IBR) with RFID TE systems.</p><p><strong>Methods: </strong>A retrospective cohort of patients who underwent IBR with RFID TEs was identified. The primary end point was occurrence of complications or identification of risk factors. The authors also evaluated the quality of magnetic resonance imaging scans (T1-weighted and T2-weighted sequences) taken for further diagnosis.</p><p><strong>Results: </strong>A total of 356 patients (mean age, 49.9 ± 9.6 years) received 471 IBR RFID TE systems. The average follow-up was 29.4 ± 16.6 months. A total of 77 patients (21.6%) experienced complications, most frequently seroma (7.8%). A greater number of complications were observed in older patients ( P = 0.005), smokers ( P = 0.009), patients who received radiotherapy ( P = 0.005), and patients who received reconstruction using a premuscular pocket ( P = 0.001). Multivariate regression found that older patients and smokers had odds ratios (ORs) of 2.12 ( P = 0.013) and 2.30 ( P = 0.024) for developing complications, respectively. Radiotherapy (OR, 2.29; P = 0.024) was also an independent risk factor for overall complications. Use of a submuscular pocket was associated with significantly lower odds of developing seroma (OR, 0.21; P = 0.08). Magnetic resonance imaging scans demonstrated excellent quality, with no artifact-related negative effects.</p><p><strong>Conclusions: </strong>Despite extensive research on IBR, previous studies on RFID TEs are limited and did not analyze predictive risk factors. These findings demonstrate that RFID TEs are reliable, with results similar to those of other series using different devices. The absence of significant imaging artifacts facilitates follow-up surveillance and represents an important advantage over traditional TEs.</p>","PeriodicalId":20128,"journal":{"name":"Plastic and reconstructive surgery","volume":" ","pages":"523-538"},"PeriodicalIF":3.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plastic and reconstructive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PRS.0000000000012921","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Most breast reconstructions are implant-based and performed in 2 stages using tissue expanders (TEs). Despite widespread indications for use, conventional TEs can present limitations, especially those containing metallic or magnetic ports. A new generation of TEs that incorporates nonmetallic radiofrequency identification systems (RFID TE) has been introduced. The authors assessed outcomes and risk factors for complications after implant-based reconstruction (IBR) with RFID TE systems.
Methods: A retrospective cohort of patients who underwent IBR with RFID TEs was identified. The primary end point was occurrence of complications or identification of risk factors. The authors also evaluated the quality of magnetic resonance imaging scans (T1-weighted and T2-weighted sequences) taken for further diagnosis.
Results: A total of 356 patients (mean age, 49.9 ± 9.6 years) received 471 IBR RFID TE systems. The average follow-up was 29.4 ± 16.6 months. A total of 77 patients (21.6%) experienced complications, most frequently seroma (7.8%). A greater number of complications were observed in older patients ( P = 0.005), smokers ( P = 0.009), patients who received radiotherapy ( P = 0.005), and patients who received reconstruction using a premuscular pocket ( P = 0.001). Multivariate regression found that older patients and smokers had odds ratios (ORs) of 2.12 ( P = 0.013) and 2.30 ( P = 0.024) for developing complications, respectively. Radiotherapy (OR, 2.29; P = 0.024) was also an independent risk factor for overall complications. Use of a submuscular pocket was associated with significantly lower odds of developing seroma (OR, 0.21; P = 0.08). Magnetic resonance imaging scans demonstrated excellent quality, with no artifact-related negative effects.
Conclusions: Despite extensive research on IBR, previous studies on RFID TEs are limited and did not analyze predictive risk factors. These findings demonstrate that RFID TEs are reliable, with results similar to those of other series using different devices. The absence of significant imaging artifacts facilitates follow-up surveillance and represents an important advantage over traditional TEs.
期刊介绍:
For more than 70 years Plastic and Reconstructive Surgery® has been the one consistently excellent reference for every specialist who uses plastic surgery techniques or works in conjunction with a plastic surgeon. Plastic and Reconstructive Surgery® , the official journal of the American Society of Plastic Surgeons, is a benefit of Society membership, and is also available on a subscription basis.
Plastic and Reconstructive Surgery® brings subscribers up-to-the-minute reports on the latest techniques and follow-up for all areas of plastic and reconstructive surgery, including breast reconstruction, experimental studies, maxillofacial reconstruction, hand and microsurgery, burn repair, cosmetic surgery, as well as news on medicolegal issues. The cosmetic section provides expanded coverage on new procedures and techniques and offers more cosmetic-specific content than any other journal. All subscribers enjoy full access to the Journal''s website, which features broadcast quality videos of reconstructive and cosmetic procedures, podcasts, comprehensive article archives dating to 1946, and additional benefits offered by the newly-redesigned website.