Rong He , Yanjie Zhu , Weiping Zhou , Muhammad Azhar Hayat Nawaz , Yunhui Li , Jianwei Zhu , Huimin Feng , Anna Maria Nowicka , Wenzhao Han , Cong Yu
{"title":"Aggregation-induced luminescence probe based lateral flow immunoassay for the simultaneous quantitative detection of IL-6/PCT","authors":"Rong He , Yanjie Zhu , Weiping Zhou , Muhammad Azhar Hayat Nawaz , Yunhui Li , Jianwei Zhu , Huimin Feng , Anna Maria Nowicka , Wenzhao Han , Cong Yu","doi":"10.1016/j.jpba.2026.117393","DOIUrl":null,"url":null,"abstract":"<div><div>The detection of important inflammatory biomarkers possesses substantial advantages in guiding clinical decision-making. In particular, simultaneous detection of interleukin-6 (IL-6) and procalcitonin (PCT) significantly improves the differentiation between bacterial and viral infections, a critical challenge in early-stage diagnostics. To address this need, a reliable lateral flow immunoassay (LFIA) incorporating aggregation-induced luminescent nanoparticles (BTA@PS) was successfully developed. A novel aggregation-induced emission (AIE) probe was designed and encapsulated within polystyrene microspheres, thereby overcoming the limitations of aggregation-caused quenching (ACQ) in conventional fluorescent materials. The resulting BTA@PS nanoparticles, conjugated with specific antibodies against IL-6 and PCT, served as stable and effective immunofluorescent probes for the LFIA platform. Under optimized experimental conditions, the developed BTA@PS-LFIA enabled simultaneous quantification of IL-6 and PCT, demonstrating excellent linearity over the range of 2–8000 pg/mL and 0.04–30 ng/mL, respectively, with coefficient of variation (CV) values of below 5 %. Furthermore, this method demonstrated superior detection capability for PCT and IL-6 in serum, confirming its high potential for rapid clinical diagnostics.</div></div>","PeriodicalId":16685,"journal":{"name":"Journal of pharmaceutical and biomedical analysis","volume":"273 ","pages":"Article 117393"},"PeriodicalIF":3.4000,"publicationDate":"2026-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmaceutical and biomedical analysis","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0731708526000610","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The detection of important inflammatory biomarkers possesses substantial advantages in guiding clinical decision-making. In particular, simultaneous detection of interleukin-6 (IL-6) and procalcitonin (PCT) significantly improves the differentiation between bacterial and viral infections, a critical challenge in early-stage diagnostics. To address this need, a reliable lateral flow immunoassay (LFIA) incorporating aggregation-induced luminescent nanoparticles (BTA@PS) was successfully developed. A novel aggregation-induced emission (AIE) probe was designed and encapsulated within polystyrene microspheres, thereby overcoming the limitations of aggregation-caused quenching (ACQ) in conventional fluorescent materials. The resulting BTA@PS nanoparticles, conjugated with specific antibodies against IL-6 and PCT, served as stable and effective immunofluorescent probes for the LFIA platform. Under optimized experimental conditions, the developed BTA@PS-LFIA enabled simultaneous quantification of IL-6 and PCT, demonstrating excellent linearity over the range of 2–8000 pg/mL and 0.04–30 ng/mL, respectively, with coefficient of variation (CV) values of below 5 %. Furthermore, this method demonstrated superior detection capability for PCT and IL-6 in serum, confirming its high potential for rapid clinical diagnostics.
期刊介绍:
This journal is an international medium directed towards the needs of academic, clinical, government and industrial analysis by publishing original research reports and critical reviews on pharmaceutical and biomedical analysis. It covers the interdisciplinary aspects of analysis in the pharmaceutical, biomedical and clinical sciences, including developments in analytical methodology, instrumentation, computation and interpretation. Submissions on novel applications focusing on drug purity and stability studies, pharmacokinetics, therapeutic monitoring, metabolic profiling; drug-related aspects of analytical biochemistry and forensic toxicology; quality assurance in the pharmaceutical industry are also welcome.
Studies from areas of well established and poorly selective methods, such as UV-VIS spectrophotometry (including derivative and multi-wavelength measurements), basic electroanalytical (potentiometric, polarographic and voltammetric) methods, fluorimetry, flow-injection analysis, etc. are accepted for publication in exceptional cases only, if a unique and substantial advantage over presently known systems is demonstrated. The same applies to the assay of simple drug formulations by any kind of methods and the determination of drugs in biological samples based merely on spiked samples. Drug purity/stability studies should contain information on the structure elucidation of the impurities/degradants.