Improved transcutaneous bilirubinometer for enhanced measurement accuracy in neonatal hyperbilirubinemia.

IF 1.1 4区 医学 Q3 MEDICAL LABORATORY TECHNOLOGY
Annals of Clinical Biochemistry Pub Date : 2026-09-01 Epub Date: 2026-02-02 DOI:10.1177/00045632261424727
Kosuke Koyano, Makoto Arioka, Yuta Noguchi, Yuta Shinabe, Tomoaki Kusaka, Hirosuke Morita, Katsufumi Nishioka, Yasuhiro Nakao, Kota Inoue, Aya Morimoto, Shinji Nakamura, Sonoko Kondo, Yukihiko Konishi, Saneyuki Yasuda, Hitoshi Okada, Konomu Hirao, Takashi Kusaka
{"title":"Improved transcutaneous bilirubinometer for enhanced measurement accuracy in neonatal hyperbilirubinemia.","authors":"Kosuke Koyano, Makoto Arioka, Yuta Noguchi, Yuta Shinabe, Tomoaki Kusaka, Hirosuke Morita, Katsufumi Nishioka, Yasuhiro Nakao, Kota Inoue, Aya Morimoto, Shinji Nakamura, Sonoko Kondo, Yukihiko Konishi, Saneyuki Yasuda, Hitoshi Okada, Konomu Hirao, Takashi Kusaka","doi":"10.1177/00045632261424727","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundConventional transcutaneous bilirubinometers often underestimate total bilirubin (TB) levels at high concentrations, limiting their clinical utility in cases of neonatal hyperbilirubinemia. We aimed to address this shortcoming by developing and testing a novel type of advanced transcutaneous bilirubinometer that may enhance the early identification of severe hyperbilirubinemia, potentially reducing the need for invasive testing and exchange transfusions.MethodsWe developed a novel transcutaneous bilirubinometer with adjustable light intensity and detection distances. Transcutaneous bilirubin (TcB) measurements were obtained using both the novel device and a conventional JM-105 bilirubinometer in 66 instances in 62 neonates (≥36 weeks gestation). TB values measured in patient blood samples were used as reference values for calculating correlations and error metrics (i.e. mean squared error [MSE] and mean absolute error [MAE]).ResultsThe novel device showed strong correlation with TB values across all concentrations (R<sup>2</sup> = 0.96), including those ≥15 mg/dL (R<sup>2</sup> = 0.84), outperforming the JM-105 device (R<sup>2</sup> = 0.60 for TBs ≥15 mg/dL). The novel device also yielded lower MSE (1.53 vs 2.95) and MAE values (1.00 vs 1.39) than the JM-105.ConclusionsOur novel transcutaneous bilirubinometer demonstrated improved accuracy at higher bilirubin concentrations compared with a conventional JM-105 device.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"369-374"},"PeriodicalIF":1.1000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632261424727","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundConventional transcutaneous bilirubinometers often underestimate total bilirubin (TB) levels at high concentrations, limiting their clinical utility in cases of neonatal hyperbilirubinemia. We aimed to address this shortcoming by developing and testing a novel type of advanced transcutaneous bilirubinometer that may enhance the early identification of severe hyperbilirubinemia, potentially reducing the need for invasive testing and exchange transfusions.MethodsWe developed a novel transcutaneous bilirubinometer with adjustable light intensity and detection distances. Transcutaneous bilirubin (TcB) measurements were obtained using both the novel device and a conventional JM-105 bilirubinometer in 66 instances in 62 neonates (≥36 weeks gestation). TB values measured in patient blood samples were used as reference values for calculating correlations and error metrics (i.e. mean squared error [MSE] and mean absolute error [MAE]).ResultsThe novel device showed strong correlation with TB values across all concentrations (R2 = 0.96), including those ≥15 mg/dL (R2 = 0.84), outperforming the JM-105 device (R2 = 0.60 for TBs ≥15 mg/dL). The novel device also yielded lower MSE (1.53 vs 2.95) and MAE values (1.00 vs 1.39) than the JM-105.ConclusionsOur novel transcutaneous bilirubinometer demonstrated improved accuracy at higher bilirubin concentrations compared with a conventional JM-105 device.

改进经皮胆红素计提高新生儿高胆红素血症的测量准确性。
背景:传统的经皮胆红素计通常低估了高浓度的总胆红素(TB)水平,限制了其在新生儿高胆红素血症病例中的临床应用。我们的目标是通过开发和测试一种新型的先进经皮胆红素计来解决这一缺点,该计可以增强对严重高胆红素血症的早期识别,潜在地减少对侵入性检测和交换输血的需求。方法:研制了一种新型经皮胆红素测量仪,其光强和检测距离可调。使用新型装置和传统的JM-105胆红素计对62例新生儿(妊娠≥36周)的66例进行了经皮胆红素(TcB)测量。患者血液样本中测得的TB值作为计算相关性和误差指标(即均方误差[MSE]和平均绝对误差[MAE])的参考值。结果:该装置与TB值在所有浓度下均具有较强的相关性(R²= 0.96),包括≥15 mg/dL (R²= 0.84),优于JM-105装置(R²= 0.60,≥15 mg/dL)。与JM-105相比,新装置的MSE(1.53比2.95)和MAE值(1.00比1.39)也更低。结论:与传统的JM-105装置相比,我们的新型经皮胆红素计在较高胆红素浓度下显示出更高的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Clinical Biochemistry
Annals of Clinical Biochemistry Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
5.20
自引率
4.50%
发文量
61
期刊介绍: Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine. Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals. Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书