Kosuke Koyano, Makoto Arioka, Yuta Noguchi, Yuta Shinabe, Tomoaki Kusaka, Hirosuke Morita, Katsufumi Nishioka, Yasuhiro Nakao, Kota Inoue, Aya Morimoto, Shinji Nakamura, Sonoko Kondo, Yukihiko Konishi, Saneyuki Yasuda, Hitoshi Okada, Konomu Hirao, Takashi Kusaka
{"title":"Improved transcutaneous bilirubinometer for enhanced measurement accuracy in neonatal hyperbilirubinemia.","authors":"Kosuke Koyano, Makoto Arioka, Yuta Noguchi, Yuta Shinabe, Tomoaki Kusaka, Hirosuke Morita, Katsufumi Nishioka, Yasuhiro Nakao, Kota Inoue, Aya Morimoto, Shinji Nakamura, Sonoko Kondo, Yukihiko Konishi, Saneyuki Yasuda, Hitoshi Okada, Konomu Hirao, Takashi Kusaka","doi":"10.1177/00045632261424727","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundConventional transcutaneous bilirubinometers often underestimate total bilirubin (TB) levels at high concentrations, limiting their clinical utility in cases of neonatal hyperbilirubinemia. We aimed to address this shortcoming by developing and testing a novel type of advanced transcutaneous bilirubinometer that may enhance the early identification of severe hyperbilirubinemia, potentially reducing the need for invasive testing and exchange transfusions.MethodsWe developed a novel transcutaneous bilirubinometer with adjustable light intensity and detection distances. Transcutaneous bilirubin (TcB) measurements were obtained using both the novel device and a conventional JM-105 bilirubinometer in 66 instances in 62 neonates (≥36 weeks gestation). TB values measured in patient blood samples were used as reference values for calculating correlations and error metrics (i.e. mean squared error [MSE] and mean absolute error [MAE]).ResultsThe novel device showed strong correlation with TB values across all concentrations (R<sup>2</sup> = 0.96), including those ≥15 mg/dL (R<sup>2</sup> = 0.84), outperforming the JM-105 device (R<sup>2</sup> = 0.60 for TBs ≥15 mg/dL). The novel device also yielded lower MSE (1.53 vs 2.95) and MAE values (1.00 vs 1.39) than the JM-105.ConclusionsOur novel transcutaneous bilirubinometer demonstrated improved accuracy at higher bilirubin concentrations compared with a conventional JM-105 device.</p>","PeriodicalId":8005,"journal":{"name":"Annals of Clinical Biochemistry","volume":" ","pages":"369-374"},"PeriodicalIF":1.1000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Clinical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00045632261424727","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
BackgroundConventional transcutaneous bilirubinometers often underestimate total bilirubin (TB) levels at high concentrations, limiting their clinical utility in cases of neonatal hyperbilirubinemia. We aimed to address this shortcoming by developing and testing a novel type of advanced transcutaneous bilirubinometer that may enhance the early identification of severe hyperbilirubinemia, potentially reducing the need for invasive testing and exchange transfusions.MethodsWe developed a novel transcutaneous bilirubinometer with adjustable light intensity and detection distances. Transcutaneous bilirubin (TcB) measurements were obtained using both the novel device and a conventional JM-105 bilirubinometer in 66 instances in 62 neonates (≥36 weeks gestation). TB values measured in patient blood samples were used as reference values for calculating correlations and error metrics (i.e. mean squared error [MSE] and mean absolute error [MAE]).ResultsThe novel device showed strong correlation with TB values across all concentrations (R2 = 0.96), including those ≥15 mg/dL (R2 = 0.84), outperforming the JM-105 device (R2 = 0.60 for TBs ≥15 mg/dL). The novel device also yielded lower MSE (1.53 vs 2.95) and MAE values (1.00 vs 1.39) than the JM-105.ConclusionsOur novel transcutaneous bilirubinometer demonstrated improved accuracy at higher bilirubin concentrations compared with a conventional JM-105 device.
期刊介绍:
Annals of Clinical Biochemistry is the fully peer reviewed international journal of the Association for Clinical Biochemistry and Laboratory Medicine.
Annals of Clinical Biochemistry accepts papers that contribute to knowledge in all fields of laboratory medicine, especially those pertaining to the understanding, diagnosis and treatment of human disease. It publishes papers on clinical biochemistry, clinical audit, metabolic medicine, immunology, genetics, biotechnology, haematology, microbiology, computing and management where they have both biochemical and clinical relevance. Papers describing evaluation or implementation of commercial reagent kits or the performance of new analysers require substantial original information. Unless of exceptional interest and novelty, studies dealing with the redox status in various diseases are not generally considered within the journal''s scope. Studies documenting the association of single nucleotide polymorphisms (SNPs) with particular phenotypes will not normally be considered, given the greater strength of genome wide association studies (GWAS). Research undertaken in non-human animals will not be considered for publication in the Annals.
Annals of Clinical Biochemistry is also the official journal of NVKC (de Nederlandse Vereniging voor Klinische Chemie) and JSCC (Japan Society of Clinical Chemistry).