Initial evaluation of a mixed-reality system for image-guided navigation during percutaneous liver tumor ablation

IF 5.5 2区 医学 Q1 ENGINEERING, BIOMEDICAL
Dominik Spinczyk , Grzegorz Rosiak , Jarosław Żyłkowski , Krzysztof Milczarek , Dariusz Konecki , Karol Zaczkowski , Agata Tomaszewska , Łukasz Przepióra , Anna Wolińska-Sołtys , Piotr Sperka , Dawid Hajda , Ewa Piętka
{"title":"Initial evaluation of a mixed-reality system for image-guided navigation during percutaneous liver tumor ablation","authors":"Dominik Spinczyk ,&nbsp;Grzegorz Rosiak ,&nbsp;Jarosław Żyłkowski ,&nbsp;Krzysztof Milczarek ,&nbsp;Dariusz Konecki ,&nbsp;Karol Zaczkowski ,&nbsp;Agata Tomaszewska ,&nbsp;Łukasz Przepióra ,&nbsp;Anna Wolińska-Sołtys ,&nbsp;Piotr Sperka ,&nbsp;Dawid Hajda ,&nbsp;Ewa Piętka","doi":"10.1016/j.compmedimag.2026.102714","DOIUrl":null,"url":null,"abstract":"<div><div>Minimally invasive ablation is a challenge for contemporary interventional radiology. This study aimed to investigate the feasibility of utilizing a mixed-reality system for this type of treatment. A HoloLens mixed reality and optical tracking system, which supports diagnosis, planning, and procedure implementation, was used for percutaneous liver tumor ablation. The system differentiated pathological liver changes at the diagnostic stage, allowing for the selection of the entry point and target during planning. Meanwhile, it provided a real-time fusion of intraoperative ultrasound images with a pre-operative hologram during the procedure. Additionally, the collision detection module enabled the detection of collisions between the ablative needle and anatomical structures, utilizing the actual needle trajectory. The system was evaluated in 11 patients with cancerous liver lesions. The mean accuracy of target point registration, selected at the planning stage, was 2.8 mm during the procedure's supporting stage. Additionally, operator depth perception improved, the effective needle trajectory was shortened, and the radiation dose was reduced for both the patient and the operator due to improved visibility of the needle within the patient’s body. A generally improved understanding of the mutual spatial relationship between anatomical structures was observed compared to the classical two-dimensional view, along with improved depth perception of the operating field. An additional advantage indicated by the operators was the real-time highlighting of anatomical structures susceptible to damage by the needle trajectory, such as blood vessels, bile ducts, and the lungs, which lowers the risk of complications.</div></div>","PeriodicalId":50631,"journal":{"name":"Computerized Medical Imaging and Graphics","volume":"128 ","pages":"Article 102714"},"PeriodicalIF":5.5000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computerized Medical Imaging and Graphics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0895611126000170","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Minimally invasive ablation is a challenge for contemporary interventional radiology. This study aimed to investigate the feasibility of utilizing a mixed-reality system for this type of treatment. A HoloLens mixed reality and optical tracking system, which supports diagnosis, planning, and procedure implementation, was used for percutaneous liver tumor ablation. The system differentiated pathological liver changes at the diagnostic stage, allowing for the selection of the entry point and target during planning. Meanwhile, it provided a real-time fusion of intraoperative ultrasound images with a pre-operative hologram during the procedure. Additionally, the collision detection module enabled the detection of collisions between the ablative needle and anatomical structures, utilizing the actual needle trajectory. The system was evaluated in 11 patients with cancerous liver lesions. The mean accuracy of target point registration, selected at the planning stage, was 2.8 mm during the procedure's supporting stage. Additionally, operator depth perception improved, the effective needle trajectory was shortened, and the radiation dose was reduced for both the patient and the operator due to improved visibility of the needle within the patient’s body. A generally improved understanding of the mutual spatial relationship between anatomical structures was observed compared to the classical two-dimensional view, along with improved depth perception of the operating field. An additional advantage indicated by the operators was the real-time highlighting of anatomical structures susceptible to damage by the needle trajectory, such as blood vessels, bile ducts, and the lungs, which lowers the risk of complications.
经皮肝肿瘤消融过程中图像引导导航混合现实系统的初步评估
微创消融是当代介入放射学面临的挑战。本研究旨在探讨利用混合现实系统进行此类治疗的可行性。HoloLens混合现实和光学跟踪系统,支持诊断、计划和程序实施,用于经皮肝肿瘤消融。该系统在诊断阶段对病理肝脏变化进行区分,允许在计划过程中选择切入点和靶点。同时,它提供了术中超声图像与术中全息图的实时融合。此外,碰撞检测模块能够检测烧蚀针与解剖结构之间的碰撞,利用实际的烧蚀针轨迹。该系统在11例肝癌患者中进行了评估。在计划阶段选择的目标点配准的平均精度在程序支持阶段为2.8 mm。此外,由于针头在患者体内的可见性提高,操作者的深度感知能力提高,有效针头轨迹缩短,患者和操作者的辐射剂量都降低了。与经典的二维视图相比,观察到对解剖结构之间相互空间关系的理解普遍提高,同时对手术视野的深度感知也有所提高。操作员指出的另一个优势是实时突出易受针头轨迹损伤的解剖结构,如血管、胆管和肺部,从而降低了并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.70
自引率
3.50%
发文量
71
审稿时长
26 days
期刊介绍: The purpose of the journal Computerized Medical Imaging and Graphics is to act as a source for the exchange of research results concerning algorithmic advances, development, and application of digital imaging in disease detection, diagnosis, intervention, prevention, precision medicine, and population health. Included in the journal will be articles on novel computerized imaging or visualization techniques, including artificial intelligence and machine learning, augmented reality for surgical planning and guidance, big biomedical data visualization, computer-aided diagnosis, computerized-robotic surgery, image-guided therapy, imaging scanning and reconstruction, mobile and tele-imaging, radiomics, and imaging integration and modeling with other information relevant to digital health. The types of biomedical imaging include: magnetic resonance, computed tomography, ultrasound, nuclear medicine, X-ray, microwave, optical and multi-photon microscopy, video and sensory imaging, and the convergence of biomedical images with other non-imaging datasets.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书