Too Early to Tell? Balancing Diagnostic Accuracy of Newborn Screening for Propionic Acidemia Versus a Timely Referral.

IF 3.5 Q1 GENETICS & HEREDITY
Nils W F Meijer, Hidde H Huidekoper, Klaas Koop, Sabine A Fuchs, M Rebecca Heiner Fokkema, Charlotte M A Lubout, Andrea B Haijer-Schreuder, Wouter F Visser, Rendelien K Verschoof-Puite, Eugènie Dekkers, Annet M Bosch, Rose E Maase, Monique G M de Sain-van der Velden
{"title":"Too Early to Tell? Balancing Diagnostic Accuracy of Newborn Screening for Propionic Acidemia Versus a Timely Referral.","authors":"Nils W F Meijer, Hidde H Huidekoper, Klaas Koop, Sabine A Fuchs, M Rebecca Heiner Fokkema, Charlotte M A Lubout, Andrea B Haijer-Schreuder, Wouter F Visser, Rendelien K Verschoof-Puite, Eugènie Dekkers, Annet M Bosch, Rose E Maase, Monique G M de Sain-van der Velden","doi":"10.3390/ijns12010001","DOIUrl":null,"url":null,"abstract":"<p><p>In the Netherlands, the newborn screening (NBS) program includes screening for propionic aciduria (PA) and methylmalonic aciduria (MMA). When initial screening reveals elevated C3 concentrations or abnormal ratios (C3/C2, C3/C16), a second-tier test measuring methylcitric acid (MCA) for PA and methylmalonic acid (MMA<sup>mb</sup>) for MMA is performed. While this two-tier approach reduces false positives effectively, it can delay referral from the NBS program and diagnosis of propionic aciduria. We describe four early-onset PA cases in which the current Dutch screening algorithm negatively impacted clinical outcomes, highlighting the need for expedited referral. We investigated different alternative screening strategies to identify the most effective approach for improving timeliness, while maintaining the high specificity of Dutch PA NBS. This revised approach prioritizes the evaluation of the C3/C2 ratio in first-tier screening. Specifically, samples with a C3/C2 ratio ≥ 0.75 should be referred directly for medical consultation and confirmatory testing. For all other samples with less pronounced biochemical abnormalities, the existing two-tier screening algorithm remains an appropriate NBS protocol. To position our approach internationally, a survey of European NBS programs was conducted to compare screening and referral protocols for PA across the region.</p>","PeriodicalId":14159,"journal":{"name":"International Journal of Neonatal Screening","volume":"12 1","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2025-12-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12821464/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Neonatal Screening","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/ijns12010001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GENETICS & HEREDITY","Score":null,"Total":0}
引用次数: 0

Abstract

In the Netherlands, the newborn screening (NBS) program includes screening for propionic aciduria (PA) and methylmalonic aciduria (MMA). When initial screening reveals elevated C3 concentrations or abnormal ratios (C3/C2, C3/C16), a second-tier test measuring methylcitric acid (MCA) for PA and methylmalonic acid (MMAmb) for MMA is performed. While this two-tier approach reduces false positives effectively, it can delay referral from the NBS program and diagnosis of propionic aciduria. We describe four early-onset PA cases in which the current Dutch screening algorithm negatively impacted clinical outcomes, highlighting the need for expedited referral. We investigated different alternative screening strategies to identify the most effective approach for improving timeliness, while maintaining the high specificity of Dutch PA NBS. This revised approach prioritizes the evaluation of the C3/C2 ratio in first-tier screening. Specifically, samples with a C3/C2 ratio ≥ 0.75 should be referred directly for medical consultation and confirmatory testing. For all other samples with less pronounced biochemical abnormalities, the existing two-tier screening algorithm remains an appropriate NBS protocol. To position our approach internationally, a survey of European NBS programs was conducted to compare screening and referral protocols for PA across the region.

Abstract Image

Abstract Image

过早下结论?平衡新生儿筛查丙酸血症的诊断准确性与及时转诊。
在荷兰,新生儿筛查(NBS)项目包括筛查丙酸尿症(PA)和甲基丙二酸尿症(MMA)。当初始筛选显示C3浓度升高或异常比率(C3/C2, C3/C16)时,进行二级测试,测量甲基柠檬酸(MCA)检测PA,甲基丙二酸(MMAmb)检测MMA。虽然这种双层方法有效地减少了假阳性,但它可能会延迟NBS项目的转诊和丙酸尿的诊断。我们描述了四个早发性PA病例,其中目前的荷兰筛选算法对临床结果产生了负面影响,强调了加速转诊的必要性。我们研究了不同的替代筛查策略,以确定最有效的方法来提高及时性,同时保持荷兰PA NBS的高特异性。修订后的方法优先评估C3/C2比率在一线筛查。具体而言,C3/C2比值≥0.75的样本应直接转诊进行医学咨询和确认性检测。对于所有其他生化异常不太明显的样本,现有的两层筛选算法仍然是适当的NBS方案。为了在国际上定位我们的方法,我们对欧洲国家统计局项目进行了一项调查,以比较整个地区PA的筛查和转诊协议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Neonatal Screening
International Journal of Neonatal Screening Medicine-Pediatrics, Perinatology and Child Health
CiteScore
6.70
自引率
20.00%
发文量
56
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书