Exploring the Feasibility of Zero-Shot Super-Resolution in Preclinical Imaging.

Omar A M Gharib, Samuel W Remedios, Blake E Dewey, Jerry L Prince, Aaron Carass
{"title":"Exploring the Feasibility of Zero-Shot Super-Resolution in Preclinical Imaging.","authors":"Omar A M Gharib, Samuel W Remedios, Blake E Dewey, Jerry L Prince, Aaron Carass","doi":"10.1007/978-3-032-04937-7_18","DOIUrl":null,"url":null,"abstract":"<p><p>Preclinical imaging studies are vital to the research, development, and evaluation of new medical therapies. Images acquired during these studies often have high in-plane resolution but low through-plane resolution, resulting in highly anisotropic volumes that hamper downstream volumetric analysis. Additionally, since there are no image acquisition standards across studies, training data for conventional supervised super-resolution (SR) methods is limited. In this work, we compare two SR methods that do not require additional training data. The first is ECLARE, a self-SR approach that creates its own training data from in-plane patches drawn from the anisotropic volume. The second is Biplanar Denoising diffusion null space model (DDNM) Averaging (BiDA), a proposed method leveraging two independently pre-trained denoising diffusion probabilistic models and the DDNM posterior sampling technique. We evaluate both methods first on rat data at two scale factors (2.5× and .5×) and compare signal recovery and downstream task performance. We further evaluate these methods on a different species (mice) to measure their generalizability. Both methods experimentally resulted in good signal recovery performance, but only the images super-resolved by BiDA were accurately skullstripped downstream. Although both methods performed well on the in-domain rat data, BiDA did not fully generalize to the out-of-domain mouse data.</p>","PeriodicalId":94280,"journal":{"name":"Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention","volume":"15961 ","pages":"186-196"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12803491/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/978-3-032-04937-7_18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Preclinical imaging studies are vital to the research, development, and evaluation of new medical therapies. Images acquired during these studies often have high in-plane resolution but low through-plane resolution, resulting in highly anisotropic volumes that hamper downstream volumetric analysis. Additionally, since there are no image acquisition standards across studies, training data for conventional supervised super-resolution (SR) methods is limited. In this work, we compare two SR methods that do not require additional training data. The first is ECLARE, a self-SR approach that creates its own training data from in-plane patches drawn from the anisotropic volume. The second is Biplanar Denoising diffusion null space model (DDNM) Averaging (BiDA), a proposed method leveraging two independently pre-trained denoising diffusion probabilistic models and the DDNM posterior sampling technique. We evaluate both methods first on rat data at two scale factors (2.5× and .5×) and compare signal recovery and downstream task performance. We further evaluate these methods on a different species (mice) to measure their generalizability. Both methods experimentally resulted in good signal recovery performance, but only the images super-resolved by BiDA were accurately skullstripped downstream. Although both methods performed well on the in-domain rat data, BiDA did not fully generalize to the out-of-domain mouse data.

探索零镜头超分辨率在临床前成像中的可行性。
临床前影像学研究对新医学疗法的研究、开发和评估至关重要。在这些研究中获得的图像通常具有高平面内分辨率但低平面分辨率,导致高度各向异性的体积,阻碍了下游的体积分析。此外,由于研究中没有图像采集标准,传统的监督超分辨率(SR)方法的训练数据是有限的。在这项工作中,我们比较了两种不需要额外训练数据的SR方法。第一种是ECLARE,一种自sr方法,它从各向异性体积中提取的平面内补丁中创建自己的训练数据。第二种是双平面去噪扩散零空间模型(DDNM)平均(BiDA),这是一种利用两个独立的预训练扩散去噪概率模型和DDNM后验抽样技术的方法。我们首先在两个比例因子(2.5倍和2.5倍)下对大鼠数据进行了评估。5x),并比较信号恢复和下游任务性能。我们进一步在不同的物种(小鼠)上评估这些方法,以衡量它们的普遍性。实验结果表明,这两种方法都具有良好的信号恢复性能,但只有经过BiDA超分辨的图像才能准确地在下游剥离。虽然这两种方法在域内大鼠数据上表现良好,但BiDA并没有完全推广到域外小鼠数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书