Kinematic alignment in total knee arthroplasty: principles, outcomes, and evolving perspectives

Journal of Joint Surgery and Research Pub Date : 2026-03-01 Epub Date: 2026-01-16 DOI:10.1016/j.jjoisr.2025.12.005
Manabu Akagawa , Loïc Villet , Ciara Harman , Charles Rivière
{"title":"Kinematic alignment in total knee arthroplasty: principles, outcomes, and evolving perspectives","authors":"Manabu Akagawa ,&nbsp;Loïc Villet ,&nbsp;Ciara Harman ,&nbsp;Charles Rivière","doi":"10.1016/j.jjoisr.2025.12.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>Mechanical alignment (MA) has traditionally guided total knee arthroplasty (TKA), seeking neutral limb alignment for all patients. However, this uniform method disregards anatomical diversity and leaves up to 20% of patients dissatisfied. Kinematic alignment (KA) was introduced to address these limitations by restoring each patient's native pre-arthritic knee alignment.</div></div><div><h3>Methods</h3><div>A literature review conducted in April 2025 examined the rationale, biomechanics, clinical outcomes, implant considerations, and future directions of KA-TKA.</div></div><div><h3>Results</h3><div>KA replicates the knee's natural joint lines and ligament balance, avoiding the soft tissue and kinematic distortions inherent to MA. Biomechanical studies show that KA better reproduces native knee kinematics and more physiological gait patterns. Clinical evidence, including randomized trials and meta-analyses, demonstrates that KA provides superior joint perception, greater patient satisfaction, and comparable implant survivorship relative to MA. Long-term data extending beyond 10 years indicate that component positioning and prosthetic limb alignment have a negligible influence on implant loosening or revision rates. Implant selection also plays a key role, with medial pivot designs and posterior cruciate ligament retention further enhancing (i.e. symbiotic effect) the kinematic and clinical benefits of KA.</div></div><div><h3>Conclusions</h3><div>KA represents a validated, patient-specific alternative to the long-standing MA paradigm. By aligning prosthetic components to each patient's anatomy rather than enforcing a neutral axis, KA enhances TKA performance without compromising implant durability. Future research should focus on refining three-dimensional assessment tools and implant designs to optimize the reproducibility and longevity of KA-TKA.</div></div>","PeriodicalId":100795,"journal":{"name":"Journal of Joint Surgery and Research","volume":"4 1","pages":"Pages 75-80"},"PeriodicalIF":0.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Joint Surgery and Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949705125000477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Mechanical alignment (MA) has traditionally guided total knee arthroplasty (TKA), seeking neutral limb alignment for all patients. However, this uniform method disregards anatomical diversity and leaves up to 20% of patients dissatisfied. Kinematic alignment (KA) was introduced to address these limitations by restoring each patient's native pre-arthritic knee alignment.

Methods

A literature review conducted in April 2025 examined the rationale, biomechanics, clinical outcomes, implant considerations, and future directions of KA-TKA.

Results

KA replicates the knee's natural joint lines and ligament balance, avoiding the soft tissue and kinematic distortions inherent to MA. Biomechanical studies show that KA better reproduces native knee kinematics and more physiological gait patterns. Clinical evidence, including randomized trials and meta-analyses, demonstrates that KA provides superior joint perception, greater patient satisfaction, and comparable implant survivorship relative to MA. Long-term data extending beyond 10 years indicate that component positioning and prosthetic limb alignment have a negligible influence on implant loosening or revision rates. Implant selection also plays a key role, with medial pivot designs and posterior cruciate ligament retention further enhancing (i.e. symbiotic effect) the kinematic and clinical benefits of KA.

Conclusions

KA represents a validated, patient-specific alternative to the long-standing MA paradigm. By aligning prosthetic components to each patient's anatomy rather than enforcing a neutral axis, KA enhances TKA performance without compromising implant durability. Future research should focus on refining three-dimensional assessment tools and implant designs to optimize the reproducibility and longevity of KA-TKA.
全膝关节置换术中的运动学对齐:原则、结果和不断发展的观点
机械对齐(MA)传统上指导全膝关节置换术(TKA),为所有患者寻求中立肢体对齐。然而,这种统一的方法忽视了解剖学的多样性,导致多达20%的患者不满意。运动学对齐(KA)的引入是为了解决这些限制,通过恢复每个患者的原生关节炎前的膝关节对齐。方法于2025年4月进行了一篇文献综述,探讨了KA-TKA的原理、生物力学、临床结果、种植注意事项和未来发展方向。结果ska复制了膝关节的自然关节线和韧带平衡,避免了MA固有的软组织和运动学扭曲。生物力学研究表明,KA更好地再现了膝关节的运动学和更生理的步态模式。包括随机试验和荟萃分析在内的临床证据表明,与MA相比,KA提供了更好的关节感知,更高的患者满意度和相当的种植体存活率。超过10年的长期数据表明,组件定位和假肢对齐对种植体松动或翻修率的影响可以忽略不计。植入物的选择也起着关键作用,内侧枢轴设计和后交叉韧带保留进一步增强了KA的运动学和临床益处(即共生效应)。结论ska代表了长期存在的MA模式的一种经过验证的、患者特异性的替代方案。通过将假体部件对准每个患者的解剖结构,而不是强制一个中性轴,KA增强了TKA的性能,而不影响植入物的耐用性。未来的研究应着眼于完善三维评估工具和种植体设计,以优化KA-TKA的重复性和寿命。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书