Evaluation of general and specialized knowledge-based planning models for prostate cancer with bowel proximity

IF 1.7 4区 医学 Q4 ONCOLOGY
Medical Dosimetry Pub Date : 2026-01-01 Epub Date: 2026-01-06 DOI:10.1016/j.meddos.2025.12.002
Chihiro Takahama BSc , Motoharu Sasaki PhD , Takeshi Kamomae PhD , Wataru Sugimoto MSc , Atsushi Itami MSc , Akira Tsuzuki PhD , Yuto Yamaji BSc , Akimi Kajino MSc , Yura Sakuka BSc , Hana Kawabata BSc , Hitoshi Ikushima MD, PhD
{"title":"Evaluation of general and specialized knowledge-based planning models for prostate cancer with bowel proximity","authors":"Chihiro Takahama BSc ,&nbsp;Motoharu Sasaki PhD ,&nbsp;Takeshi Kamomae PhD ,&nbsp;Wataru Sugimoto MSc ,&nbsp;Atsushi Itami MSc ,&nbsp;Akira Tsuzuki PhD ,&nbsp;Yuto Yamaji BSc ,&nbsp;Akimi Kajino MSc ,&nbsp;Yura Sakuka BSc ,&nbsp;Hana Kawabata BSc ,&nbsp;Hitoshi Ikushima MD, PhD","doi":"10.1016/j.meddos.2025.12.002","DOIUrl":null,"url":null,"abstract":"<div><div>This study evaluated knowledge-based planning (KBP) models for prostate cancer, focusing on cases where the bowel lies close to the planning target volume excluding the rectum (PTV-R). Such proximity increases toxicity risk, raising the question of whether a Special Model (Model-S) is required. Although General Models are widely applicable, their performance in bowel proximity cases remains uncertain. A General Model (Model-G) was trained with 30 standard cases and a Model-S with 30 bowel proximity cases. Thirteen additional proximity cases were used for independent evaluation. RapidPlan-generated plans (Plan-G and Plan-S) were compared with clinically used manual plans (Plan-M). Plan quality was evaluated using D98% and D2% for targets, dose-volume indices for the rectum and bladder, and D0.1/D1 cc for the bowel. Statistical analyses employed the Mann–Whitney U and paired t-tests (<em>p</em> &lt; 0.05). In the independent evaluation, Plan-M achieved significantly lower D2% than Plan-G (<em>p</em> &lt; 0.001), while Plan-S showed no significant difference (<em>P</em> = 0.069). Organ-at-risk sparing was comparable across all plans (<em>p</em> &gt; 0.05). Among the 13 evaluation cases, one Plan-G slightly exceeded the bowel D1 cc constraint of 60 Gy, indicating that in such bowel-descended cases, manual re-optimization or use of the Special Model may be required, defining the boundary where General Models remain reliable. Both models yielded clinically acceptable plans, and no clear dosimetric advantage was observed for the Special Model. These findings demonstrate the robustness of KBP against anatomical variability and highlight its potential as a foundation for future AI-assisted adaptive radiotherapy frameworks.</div></div>","PeriodicalId":49837,"journal":{"name":"Medical Dosimetry","volume":"51 2","pages":"Pages 218-224"},"PeriodicalIF":1.7000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Dosimetry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958394725000779","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/6 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated knowledge-based planning (KBP) models for prostate cancer, focusing on cases where the bowel lies close to the planning target volume excluding the rectum (PTV-R). Such proximity increases toxicity risk, raising the question of whether a Special Model (Model-S) is required. Although General Models are widely applicable, their performance in bowel proximity cases remains uncertain. A General Model (Model-G) was trained with 30 standard cases and a Model-S with 30 bowel proximity cases. Thirteen additional proximity cases were used for independent evaluation. RapidPlan-generated plans (Plan-G and Plan-S) were compared with clinically used manual plans (Plan-M). Plan quality was evaluated using D98% and D2% for targets, dose-volume indices for the rectum and bladder, and D0.1/D1 cc for the bowel. Statistical analyses employed the Mann–Whitney U and paired t-tests (p < 0.05). In the independent evaluation, Plan-M achieved significantly lower D2% than Plan-G (p < 0.001), while Plan-S showed no significant difference (P = 0.069). Organ-at-risk sparing was comparable across all plans (p > 0.05). Among the 13 evaluation cases, one Plan-G slightly exceeded the bowel D1 cc constraint of 60 Gy, indicating that in such bowel-descended cases, manual re-optimization or use of the Special Model may be required, defining the boundary where General Models remain reliable. Both models yielded clinically acceptable plans, and no clear dosimetric advantage was observed for the Special Model. These findings demonstrate the robustness of KBP against anatomical variability and highlight its potential as a foundation for future AI-assisted adaptive radiotherapy frameworks.
评估一般和专业知识为基础的规划模型前列腺癌与肠邻近。
本研究评估了基于知识的前列腺癌规划(KBP)模型,重点关注肠道靠近规划目标体积(不包括直肠)的病例。这样的接近增加了毒性风险,提出了是否需要特殊型号(Model- s)的问题。虽然通用模型广泛适用,但其在肠邻近病例中的表现仍不确定。一般模型(模型- g)训练30例标准病例,模型- s训练30例肠邻近病例。另外13例邻近病例用于独立评估。rapidplan生成的计划(Plan-G和Plan-S)与临床使用的手动计划(Plan-M)进行比较。以D98%和D2%为靶标,直肠和膀胱的剂量-体积指数,肠的D0.1/D1 cc评估计划质量。统计分析采用Mann-Whitney U检验和配对t检验(p  0.05)。在13例评估病例中,有1例Plan-G略超过肠道D1 cc限制60 Gy,说明在此类肠道下降病例中,可能需要人工重新优化或使用Special Model,以确定General Models保持可靠的边界。两种模型均产生临床可接受的方案,特殊模型未观察到明显的剂量学优势。这些发现证明了KBP对解剖变异的稳健性,并突出了其作为未来人工智能辅助适应性放疗框架基础的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Dosimetry
Medical Dosimetry 医学-核医学
CiteScore
2.40
自引率
0.00%
发文量
51
审稿时长
34 days
期刊介绍: Medical Dosimetry, the official journal of the American Association of Medical Dosimetrists, is the key source of information on new developments for the medical dosimetrist. Practical and comprehensive in coverage, the journal features original contributions and review articles by medical dosimetrists, oncologists, physicists, and radiation therapy technologists on clinical applications and techniques of external beam, interstitial, intracavitary and intraluminal irradiation in cancer management. Articles dealing primarily with physics will be reviewed by a specially appointed team of experts in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书