Humeral head deviation and velocity in multidirectional instability of the glenohumeral joint: a cine magnetic resonance imaging study

IF 2 Q2 Medicine
JSES International Pub Date : 2026-03-01 Epub Date: 2025-12-02 DOI:10.1016/j.jseint.2025.101419
Kazuhisa Matsui PT, PhD, MSc , Takashi Tachibana PT , Katsuya Nobuhara MD, PhD , Yasushi Uchiyama PT, PhD
{"title":"Humeral head deviation and velocity in multidirectional instability of the glenohumeral joint: a cine magnetic resonance imaging study","authors":"Kazuhisa Matsui PT, PhD, MSc ,&nbsp;Takashi Tachibana PT ,&nbsp;Katsuya Nobuhara MD, PhD ,&nbsp;Yasushi Uchiyama PT, PhD","doi":"10.1016/j.jseint.2025.101419","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Manual clinical tests for shoulder instability rely heavily on subjective assessments of humeral head translation, making objective quantification challenging. This study hypothesized that patients with multidirectional glenohumeral instability (MDI) would demonstrate greater humeral head deviation and faster deviation velocity than healthy controls during active shoulder rotation, as assessed using cine magnetic resonance imaging (MRI).</div></div><div><h3>Methods</h3><div>Fourteen participants (eight shoulders with MDI and 20 healthy shoulders) underwent cine MRI while performing active shoulder rotation with the arm at the side. Humeral head deviation, deviation amplitude, and deviation velocity were calculated and compared between the groups using Welch's <em>t</em>-test.</div></div><div><h3>Results</h3><div>The MDI group showed significantly greater humeral head deviation, wider amplitude of deviation, and faster deviation velocity than the control group (<em>P</em> = .008 for anterior deviation, <em>P</em> = .009 for posterior deviation). The deviation amplitude exceeded 35% of the glenoid width in MDI shoulders, surpassing established clinical thresholds.</div></div><div><h3>Conclusion</h3><div>Patients with MDI demonstrated quantifiable dynamic instability on cine MRI. This modality may provide objective support for clinical findings. However, validation in larger cohorts is warranted to confirm these findings, given the limited number of MDI shoulders (n = 8).</div></div>","PeriodicalId":34444,"journal":{"name":"JSES International","volume":"10 2","pages":"Article 101419"},"PeriodicalIF":2.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSES International","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666638325003275","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Manual clinical tests for shoulder instability rely heavily on subjective assessments of humeral head translation, making objective quantification challenging. This study hypothesized that patients with multidirectional glenohumeral instability (MDI) would demonstrate greater humeral head deviation and faster deviation velocity than healthy controls during active shoulder rotation, as assessed using cine magnetic resonance imaging (MRI).

Methods

Fourteen participants (eight shoulders with MDI and 20 healthy shoulders) underwent cine MRI while performing active shoulder rotation with the arm at the side. Humeral head deviation, deviation amplitude, and deviation velocity were calculated and compared between the groups using Welch's t-test.

Results

The MDI group showed significantly greater humeral head deviation, wider amplitude of deviation, and faster deviation velocity than the control group (P = .008 for anterior deviation, P = .009 for posterior deviation). The deviation amplitude exceeded 35% of the glenoid width in MDI shoulders, surpassing established clinical thresholds.

Conclusion

Patients with MDI demonstrated quantifiable dynamic instability on cine MRI. This modality may provide objective support for clinical findings. However, validation in larger cohorts is warranted to confirm these findings, given the limited number of MDI shoulders (n = 8).
肱骨关节多向不稳定中的肱骨头偏移和速度:一项电影磁共振成像研究
背景:肩关节不稳定的手工临床试验在很大程度上依赖于对肱骨头平移的主观评估,使得客观量化具有挑战性。通过电影磁共振成像(MRI)评估,本研究假设患有多向肩关节不稳定(MDI)的患者在主动肩关节旋转时比健康对照者表现出更大的肱骨头偏移和更快的偏移速度。方法14例受试者(8例MDI肩关节和20例健康肩关节)在进行主动肩关节侧旋时行MRI检查。采用Welch’st检验计算组间肱骨头偏差、偏差幅度、偏差速度。结果与对照组相比,MDI组肱骨头偏大、偏幅宽、偏速快(前偏P = 0.008,后偏P = 0.009)。MDI患者的偏离幅度超过肩关节盂宽度的35%,超过了既定的临床阈值。结论MDI患者在MRI上表现出可量化的动态不稳定性。这种模式可以为临床结果提供客观支持。然而,考虑到MDI肩胛骨数量有限(n = 8),需要在更大的队列中进行验证以证实这些发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JSES International
JSES International Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
174
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书