Target Coverage Improvement With Dose Matching in Carbon-Ion Radiation Therapy for Pancreatic Cancer.

IF 2 Q3 ONCOLOGY
International Journal of Particle Therapy Pub Date : 2025-08-29 eCollection Date: 2025-12-01 DOI:10.1016/j.ijpt.2025.101201
Yohsuke Kusano, Hiroyuki Katoh, Yoshiki Takayama, Junya Nagata, Shogo Kurokawa, Terufumi Kusunoki, Koh Imura, Keisuke Tsuchida, Daisaku Yoshida, Tadashi Kamada, Atsushi Ito, Shinichi Minohara
{"title":"Target Coverage Improvement With Dose Matching in Carbon-Ion Radiation Therapy for Pancreatic Cancer.","authors":"Yohsuke Kusano, Hiroyuki Katoh, Yoshiki Takayama, Junya Nagata, Shogo Kurokawa, Terufumi Kusunoki, Koh Imura, Keisuke Tsuchida, Daisaku Yoshida, Tadashi Kamada, Atsushi Ito, Shinichi Minohara","doi":"10.1016/j.ijpt.2025.101201","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Although carbon-ion radiation therapy (CIRT) creates a sharp dose distribution, inaccurate irradiation positioning may reduce the tumor dose. In pancreatic CIRT, interfractional tumor motion is a factor causing tumor dose reduction. This motion is typically accounted for in the planning target volume, and it cannot provide sufficient margin because the tumor is surrounded by the gastrointestinal tract. Online adaptive radiation therapy (ART) can solve this problem, but other problems such as equipment design and excessive time consumption remain in CIRT. The purpose of this feasibility study was to evaluate the effectiveness of dose matching (DM), which is more convenient than ART in pancreatic CIRT.</p><p><strong>Materials and methods: </strong>On the in-room computed tomography images, search isocenters were placed 3 dimensionally around the isocenter determined by target matching (TM) at 0.2 cm intervals. The fractional dose distributions were then calculated at each isocenter. The coordinate with the best clinical target volume coverage (CTV V95%) was determined as the DM isocenter. In actual treatment, the use of couch shifting is assumed for irradiation in accordance with the DM isocenter. To evaluate the effectiveness of DM, variations from the initial plan for CTV V95% (ie, ΔCTV V95%) and organ-at-risk (OAR) dose (ΔD<sub>OAR</sub>) in bone matching (BM), TM, and DM were compared.</p><p><strong>Results: </strong>The median ΔCTV V95% values in BM, TM, and DM were -2.18%, -1.39%, and -0.36%, respectively. DM significantly improved CTV V95%. OAR doses were within their limits. Toxicity in DM was considered equivalent to that in BM because the maximum ΔD<sub>OAR</sub> in DM was similar to the BM results.</p><p><strong>Conclusion: </strong>DM significantly improved CTV V95% in pancreatic CIRT within dose constraints of OARs. However, DM should be properly applied by considering treatment efficacy and efficiency. The appropriate use of TM, DM, and online/offline ART is required for each treatment site to improve the target coverage.</p>","PeriodicalId":36923,"journal":{"name":"International Journal of Particle Therapy","volume":"18 ","pages":"101201"},"PeriodicalIF":2.0000,"publicationDate":"2025-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12746089/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Particle Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ijpt.2025.101201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Although carbon-ion radiation therapy (CIRT) creates a sharp dose distribution, inaccurate irradiation positioning may reduce the tumor dose. In pancreatic CIRT, interfractional tumor motion is a factor causing tumor dose reduction. This motion is typically accounted for in the planning target volume, and it cannot provide sufficient margin because the tumor is surrounded by the gastrointestinal tract. Online adaptive radiation therapy (ART) can solve this problem, but other problems such as equipment design and excessive time consumption remain in CIRT. The purpose of this feasibility study was to evaluate the effectiveness of dose matching (DM), which is more convenient than ART in pancreatic CIRT.

Materials and methods: On the in-room computed tomography images, search isocenters were placed 3 dimensionally around the isocenter determined by target matching (TM) at 0.2 cm intervals. The fractional dose distributions were then calculated at each isocenter. The coordinate with the best clinical target volume coverage (CTV V95%) was determined as the DM isocenter. In actual treatment, the use of couch shifting is assumed for irradiation in accordance with the DM isocenter. To evaluate the effectiveness of DM, variations from the initial plan for CTV V95% (ie, ΔCTV V95%) and organ-at-risk (OAR) dose (ΔDOAR) in bone matching (BM), TM, and DM were compared.

Results: The median ΔCTV V95% values in BM, TM, and DM were -2.18%, -1.39%, and -0.36%, respectively. DM significantly improved CTV V95%. OAR doses were within their limits. Toxicity in DM was considered equivalent to that in BM because the maximum ΔDOAR in DM was similar to the BM results.

Conclusion: DM significantly improved CTV V95% in pancreatic CIRT within dose constraints of OARs. However, DM should be properly applied by considering treatment efficacy and efficiency. The appropriate use of TM, DM, and online/offline ART is required for each treatment site to improve the target coverage.

剂量匹配提高胰腺癌碳离子放射治疗的靶覆盖率。
目的:虽然碳离子放射治疗(CIRT)产生了一个尖锐的剂量分布,但不准确的照射定位可能会降低肿瘤剂量。在胰腺CIRT中,肿瘤分级间运动是导致肿瘤剂量降低的一个因素。这种运动通常在规划靶体积时被考虑在内,但由于肿瘤被胃肠道包围,它不能提供足够的切缘。在线适应性放射治疗(ART)可以解决这一问题,但CIRT仍然存在设备设计和过多的时间消耗等其他问题。本可行性研究的目的是评估剂量匹配(DM)在胰腺CIRT中比ART更方便的有效性。材料与方法:在室内计算机断层扫描图像上,以0.2 cm的间隔在目标匹配(target matching, TM)确定的等心周围三维放置搜索等心。然后计算每个等中心的分数剂量分布。确定最佳临床靶体积覆盖率(CTV V95%)的坐标为DM等中心。在实际治疗中,根据DM等中心假定采用移床照射。为了评估DM的有效性,比较了初始计划中CTV V95%(即ΔCTV V95%)和器官危险(OAR)剂量(ΔDOAR)在骨匹配(BM)、TM和DM中的变化。结果:BM、TM和DM的中位ΔCTV V95%值分别为-2.18%、-1.39%和-0.36%。DM显著提高CTV V95%。桨剂量在其限制范围内。DM的毒性被认为与BM相当,因为DM的最大值ΔDOAR与BM的结果相似。结论:在OARs的剂量限制下,DM可显著提高胰腺CIRT的CTV V95%。但应综合考虑治疗效果和效率,合理应用DM。每个治疗地点需要适当使用TM、DM和在线/离线ART,以提高目标覆盖率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Particle Therapy
International Journal of Particle Therapy Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
3.70
自引率
5.90%
发文量
23
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书