A Pharmacokinetic Analysis of Intravenous Fluconazole in Adult Patients Undergoing Mechanical Circulatory Support Device Implantation.

IF 4 2区 医学 Q1 PHARMACOLOGY & PHARMACY
Clinical Pharmacokinetics Pub Date : 2026-03-01 Epub Date: 2025-12-22 DOI:10.1007/s40262-025-01607-z
Kelly A Cairns, Maria Patricia Hernandez-Mitre, Trisha N Peel, Iain J Abbott, David M Kaye, Silvana Marasco, David Daly, Victoria Warner, Anna Coldham, Jeffrey D Pope, Hans G Schneider, Michael J Dooley, Xin Liu, Jason A Roberts, Andrew A Udy
{"title":"A Pharmacokinetic Analysis of Intravenous Fluconazole in Adult Patients Undergoing Mechanical Circulatory Support Device Implantation.","authors":"Kelly A Cairns, Maria Patricia Hernandez-Mitre, Trisha N Peel, Iain J Abbott, David M Kaye, Silvana Marasco, David Daly, Victoria Warner, Anna Coldham, Jeffrey D Pope, Hans G Schneider, Michael J Dooley, Xin Liu, Jason A Roberts, Andrew A Udy","doi":"10.1007/s40262-025-01607-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>There is limited information on the pharmacokinetics and optimal dosing of fluconazole in patients undergoing mechanical circulatory support (MCS) device implantation.</p><p><strong>Aim: </strong>The aim of this study was to describe fluconazole pharmacokinetics and identify dosing regimens that achieve pharmacokinetic/pharmacodynamic targets in this patient cohort.</p><p><strong>Methods: </strong>In this prospective, single-centre study, adults undergoing MCS device implantation received intravenous fluconazole 200 mg or 400 mg, continued once daily for 5 days. Fluconazole concentrations were measured at four peri-operative time points, on return to the intensive care unit, and on days 3 and 5 following implantation. The area under the concentration-time curve from time zero to 24 h (AUC<sub>0-24</sub>) was estimated, with target exposures defined as AUC<sub>0-24</sub>/minimum inhibitory concentration (MIC) ≥ 50 for prophylaxis and AUC<sub>0-24</sub>/MIC ≥ 100 for therapy. Population pharmacokinetic modelling was performed using non-linear mixed-effects methods and for Monte Carlo dosing simulations.</p><p><strong>Results: </strong>Sixty-five fluconazole concentrations from 10 male patients (median age 51.5 years; IQR 50.0-57.0) were included. A two-compartment model including an additional renal replacement therapy (RRT)-dependent clearance pathway best described the data. Parameter estimates from the final model included a central volume of distribution of 5.75 L, non-RRT clearance of 0.45 L/h, and RRT clearance of 2.22 L/h. Simulations showed that doses of 800 mg or 12 mg/kg would be required for the highest probability of target attainment for Candida fluconazole MICs up to 4 mg/L (AUC<sub>0-24</sub>/MIC ≥ 50) and 2 mg/L (AUC<sub>0-24</sub>/MIC ≥ 100).</p><p><strong>Conclusion: </strong>In patients undergoing MCS device implantation, intravenous fluconazole 200 mg administered pre-operatively and continued daily for 5 days is insufficient for Candida spp. with MICs > 1 mg/L (prophylaxis, AUC<sub>0-24</sub>/MIC ≥ 50) and > 0.5 mg/L (treatment, AUC<sub>0-24</sub>/MIC ≥ 100).</p>","PeriodicalId":10405,"journal":{"name":"Clinical Pharmacokinetics","volume":" ","pages":"395-404"},"PeriodicalIF":4.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Pharmacokinetics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s40262-025-01607-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/22 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective: There is limited information on the pharmacokinetics and optimal dosing of fluconazole in patients undergoing mechanical circulatory support (MCS) device implantation.

Aim: The aim of this study was to describe fluconazole pharmacokinetics and identify dosing regimens that achieve pharmacokinetic/pharmacodynamic targets in this patient cohort.

Methods: In this prospective, single-centre study, adults undergoing MCS device implantation received intravenous fluconazole 200 mg or 400 mg, continued once daily for 5 days. Fluconazole concentrations were measured at four peri-operative time points, on return to the intensive care unit, and on days 3 and 5 following implantation. The area under the concentration-time curve from time zero to 24 h (AUC0-24) was estimated, with target exposures defined as AUC0-24/minimum inhibitory concentration (MIC) ≥ 50 for prophylaxis and AUC0-24/MIC ≥ 100 for therapy. Population pharmacokinetic modelling was performed using non-linear mixed-effects methods and for Monte Carlo dosing simulations.

Results: Sixty-five fluconazole concentrations from 10 male patients (median age 51.5 years; IQR 50.0-57.0) were included. A two-compartment model including an additional renal replacement therapy (RRT)-dependent clearance pathway best described the data. Parameter estimates from the final model included a central volume of distribution of 5.75 L, non-RRT clearance of 0.45 L/h, and RRT clearance of 2.22 L/h. Simulations showed that doses of 800 mg or 12 mg/kg would be required for the highest probability of target attainment for Candida fluconazole MICs up to 4 mg/L (AUC0-24/MIC ≥ 50) and 2 mg/L (AUC0-24/MIC ≥ 100).

Conclusion: In patients undergoing MCS device implantation, intravenous fluconazole 200 mg administered pre-operatively and continued daily for 5 days is insufficient for Candida spp. with MICs > 1 mg/L (prophylaxis, AUC0-24/MIC ≥ 50) and > 0.5 mg/L (treatment, AUC0-24/MIC ≥ 100).

成人机械循环支持装置植入患者静脉注射氟康唑的药代动力学分析。
背景与目的:关于氟康唑在机械循环支持(MCS)装置植入患者中的药代动力学和最佳剂量的信息有限。目的:本研究的目的是描述氟康唑的药代动力学,并确定在该患者队列中达到药代动力学/药效学目标的给药方案。方法:在这项前瞻性单中心研究中,接受MCS装置植入的成人静脉注射氟康唑200mg或400mg,每天持续一次,持续5天。在4个围手术期时间点、返回重症监护病房时以及植入后第3天和第5天测量氟康唑浓度。估计从时间0到24 h的浓度-时间曲线下面积(AUC0-24),目标暴露定义为AUC0-24/最低抑制浓度(MIC)≥50(预防)和AUC0-24/MIC≥100(治疗)。种群药代动力学建模采用非线性混合效应方法和蒙特卡罗给药模拟。结果:纳入10例男性患者(中位年龄51.5岁,IQR为50.0-57.0)的65个氟康唑浓度。包括额外的肾替代治疗(RRT)依赖的清除途径的双室模型最好地描述了数据。最终模型的参数估计包括中心容积分布为5.75 L,非RRT清除率为0.45 L/h, RRT清除率为2.22 L/h。模拟结果表明,对于高达4 mg/L (AUC0-24/MIC≥50)和2 mg/L (AUC0-24/MIC≥100)的氟康唑假丝酵母,最高可能需要800 mg或12 mg/kg的剂量才能达到目标。结论:MCS装置植入患者术前静脉注射氟康唑200 mg,每日持续5天,对于MIC为> 1 mg/L(预防,AUC0-24/MIC≥50)和> 0.5 mg/L(治疗,AUC0-24/MIC≥100)的念珠菌属是不够的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
8.80
自引率
4.40%
发文量
86
审稿时长
6-12 weeks
期刊介绍: Clinical Pharmacokinetics promotes the continuing development of clinical pharmacokinetics and pharmacodynamics for the improvement of drug therapy, and for furthering postgraduate education in clinical pharmacology and therapeutics. Pharmacokinetics, the study of drug disposition in the body, is an integral part of drug development and rational use. Knowledge and application of pharmacokinetic principles leads to accelerated drug development, cost effective drug use and a reduced frequency of adverse effects and drug interactions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书