Determination of insensible water loss and sodium accumulation behavior from the Medtronic Nautilus Extracorporeal Membrane Oxygenation (ECMO) oxygenator: An in vitro study.

The journal of extra-corporeal technology Pub Date : 2025-12-01 Epub Date: 2025-12-17 DOI:10.1051/ject/2025026
Carrie Whittaker Striker, Gabriel Kong
{"title":"Determination of insensible water loss and sodium accumulation behavior from the Medtronic Nautilus Extracorporeal Membrane Oxygenation (ECMO) oxygenator: An in vitro study.","authors":"Carrie Whittaker Striker, Gabriel Kong","doi":"10.1051/ject/2025026","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Fluid and electrolyte balance is closely managed in extracorporeal membrane oxygenation (ECMO) patients. Neglecting oxygenator-related insensible fluid losses can distort fluid balance and electrolyte levels. While ECMO oxygenator insensible losses are reported, they remain undefined for the Medtronic Nautilus oxygenator. Through in vitro analysis of the Nautilus, we quantified insensible water losses while concurrently observing sodium behavior.</p><p><strong>Methods: </strong>Insensible water losses were determined using a closed circuit. A 12-hour pilot run was conducted to saturate the oxygenator and determine probable water loss rates and sodium accumulation behaviors. Fluid loss and sodium measurements were made at 0, 6, and 12 h. Immediately following the pilot run, three randomly assigned sweep gas rates, 0.5, 1.0, and 1.5 L/min, were evaluated over a 24 h period and replicated in triplicate. The circuit parameters were consistent and controlled for each trial. Data were collected at 0, 12, and 24 h for visualized water loss in the reservoir. After each trial, sterile water was introduced into the circuit via syringe and recorded as replacement volume. Sodium measurements were made for three trials (0.5, 1.0, and 1.5) and collected at 0 and 24 h.</p><p><strong>Results: </strong>Using linear regression analysis, the following insensible water loss equations were produced. Visualized volume: 2.74 mL/h per 1 L/min sweep gas rate or 65.66 mL/day per 1 L/min of sweep gas rate (p < 0.001). Replacement volume: 3.02 mL/h per 1 L/min of sweep gas rate or 72.5 mL/day per 1 L/min of sweep rate (p < 0.001). Sodium accumulation was observed, but not statistically significant due to the small sample size.</p><p><strong>Conclusion: </strong>Insensible water loss in the Nautilus ECMO oxygenator increases linearly with sweep gas rate (p < 0.001), leading to sodium accumulation through evaporation. These losses and the associated risk for hypernatremia should be considered when managing a patient's fluid and electrolyte balance on ECMO.</p>","PeriodicalId":519952,"journal":{"name":"The journal of extra-corporeal technology","volume":"57 4","pages":"201-208"},"PeriodicalIF":0.0000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12710248/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of extra-corporeal technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2025026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Fluid and electrolyte balance is closely managed in extracorporeal membrane oxygenation (ECMO) patients. Neglecting oxygenator-related insensible fluid losses can distort fluid balance and electrolyte levels. While ECMO oxygenator insensible losses are reported, they remain undefined for the Medtronic Nautilus oxygenator. Through in vitro analysis of the Nautilus, we quantified insensible water losses while concurrently observing sodium behavior.

Methods: Insensible water losses were determined using a closed circuit. A 12-hour pilot run was conducted to saturate the oxygenator and determine probable water loss rates and sodium accumulation behaviors. Fluid loss and sodium measurements were made at 0, 6, and 12 h. Immediately following the pilot run, three randomly assigned sweep gas rates, 0.5, 1.0, and 1.5 L/min, were evaluated over a 24 h period and replicated in triplicate. The circuit parameters were consistent and controlled for each trial. Data were collected at 0, 12, and 24 h for visualized water loss in the reservoir. After each trial, sterile water was introduced into the circuit via syringe and recorded as replacement volume. Sodium measurements were made for three trials (0.5, 1.0, and 1.5) and collected at 0 and 24 h.

Results: Using linear regression analysis, the following insensible water loss equations were produced. Visualized volume: 2.74 mL/h per 1 L/min sweep gas rate or 65.66 mL/day per 1 L/min of sweep gas rate (p < 0.001). Replacement volume: 3.02 mL/h per 1 L/min of sweep gas rate or 72.5 mL/day per 1 L/min of sweep rate (p < 0.001). Sodium accumulation was observed, but not statistically significant due to the small sample size.

Conclusion: Insensible water loss in the Nautilus ECMO oxygenator increases linearly with sweep gas rate (p < 0.001), leading to sodium accumulation through evaporation. These losses and the associated risk for hypernatremia should be considered when managing a patient's fluid and electrolyte balance on ECMO.

Abstract Image

Abstract Image

Abstract Image

测定美敦力鹦鹉螺体外膜氧合(ECMO)氧合器的无意识失水和钠积聚行为:一项体外研究。
简介:在体外膜氧合(ECMO)患者中,流体和电解质平衡是密切管理的。忽略与氧合器相关的不敏感液体损失会扭曲液体平衡和电解质水平。虽然有ECMO氧合器昏迷损失的报道,但美敦力Nautilus氧合器的昏迷损失仍未明确。通过对鹦鹉螺的体外分析,我们在观察钠离子行为的同时,量化了鹦鹉螺的不敏感水分损失。方法:采用闭路检测不感失水。进行了12小时的试运行,以使氧合器饱和,并确定可能的失水速率和钠积累行为。在第0、6和12小时测量失液量和钠含量。试运行后,在24小时内评估随机分配的三种扫气速率,0.5、1.0和1.5 L/min,并重复三次。每次试验的电路参数一致且可控。在0、12和24 h收集数据,以显示水库的失水情况。每次试验结束后,通过注射器将无菌水引入回路,并记录替换量。在3个试验(0.5、1.0和1.5)中测量钠含量,并在0和24 h时收集数据。结果:通过线性回归分析,得出以下不敏感水分流失方程。可视化体积:每1 L/min扫气速率2.74 mL/h或每1 L/min扫气速率65.66 mL/d (p)结论:鹦鹉螺ECMO氧合器中不敏感水分损失随扫气速率线性增加(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书