SAN-Wavelet cycleGAN for anatomical structure reinforcement and tissue detail preservation in abdominal CT synthesis

IF 5.5 2区 医学 Q1 ENGINEERING, BIOMEDICAL
Yueyu Huang , Lu Qiang , Wenyu Xing , Tao Jiang , Yucheng He , Yuan Liu , Gaobo Zhang , Jingxian Wang , Xiaojun Song , Yifang Li
{"title":"SAN-Wavelet cycleGAN for anatomical structure reinforcement and tissue detail preservation in abdominal CT synthesis","authors":"Yueyu Huang ,&nbsp;Lu Qiang ,&nbsp;Wenyu Xing ,&nbsp;Tao Jiang ,&nbsp;Yucheng He ,&nbsp;Yuan Liu ,&nbsp;Gaobo Zhang ,&nbsp;Jingxian Wang ,&nbsp;Xiaojun Song ,&nbsp;Yifang Li","doi":"10.1016/j.compmedimag.2025.102686","DOIUrl":null,"url":null,"abstract":"<div><div>Generating a CT image from an existing but unpaired MR image has recently become a promising objective in the radiotherapy treatment planning (RTP), whereas the unsatisfactory structure and detail accuracy of the outcome is still a challenge for its clinical application. To address this issue, this work proposed an unsupervised model called structure-adaptive normalization wavelet (SAN-Wavelet) cycleGAN for unpaired MR-to-CT image synthesis. This method not only developed a module called SAN to ensure the anatomically structural integrity, but also introduced a neighborhood detail loss (ND loss) for detail consistency penalization between different modalities. Furthermore, a high-frequency discriminator and wavelet-trans skip connection were designed to keep with the high-frequency tissue detail. Experimental findings on abdominal area demonstrated the effectiveness of SAN-Wavelet cycleGAN for unpaired MR-to-CT synthesis, with mean squared error (MSE) of 66.38, root mean squared error (RMSE) of 8.07, peak signal-to-noise ratio (PSNR) of 25.944 dB, structural similarity index (SSlM) of 0.895 and mixture perceptual similarity index (MPSIM) of 0.723. Compared to other unsupervised approaches (i.e., cycleGAN, gc-, cc-, and sc-cycleGAN), the performances of SAN-cycleGAN improved by 5–15 % in terms of the metrics above. Moreover, the dosimetric distributions of the synthesized CT and real CT in planning target volume (PTV-45Gy) and organ at risk area (bowel) were statistically consistent (Mann-Whitney U test, P &gt; 0.05) with a mean relative error being 0.09 % and 0.24 %, showcasing a promising applicability for clinical application.</div></div>","PeriodicalId":50631,"journal":{"name":"Computerized Medical Imaging and Graphics","volume":"127 ","pages":"Article 102686"},"PeriodicalIF":5.5000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computerized Medical Imaging and Graphics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0895611125001958","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Generating a CT image from an existing but unpaired MR image has recently become a promising objective in the radiotherapy treatment planning (RTP), whereas the unsatisfactory structure and detail accuracy of the outcome is still a challenge for its clinical application. To address this issue, this work proposed an unsupervised model called structure-adaptive normalization wavelet (SAN-Wavelet) cycleGAN for unpaired MR-to-CT image synthesis. This method not only developed a module called SAN to ensure the anatomically structural integrity, but also introduced a neighborhood detail loss (ND loss) for detail consistency penalization between different modalities. Furthermore, a high-frequency discriminator and wavelet-trans skip connection were designed to keep with the high-frequency tissue detail. Experimental findings on abdominal area demonstrated the effectiveness of SAN-Wavelet cycleGAN for unpaired MR-to-CT synthesis, with mean squared error (MSE) of 66.38, root mean squared error (RMSE) of 8.07, peak signal-to-noise ratio (PSNR) of 25.944 dB, structural similarity index (SSlM) of 0.895 and mixture perceptual similarity index (MPSIM) of 0.723. Compared to other unsupervised approaches (i.e., cycleGAN, gc-, cc-, and sc-cycleGAN), the performances of SAN-cycleGAN improved by 5–15 % in terms of the metrics above. Moreover, the dosimetric distributions of the synthesized CT and real CT in planning target volume (PTV-45Gy) and organ at risk area (bowel) were statistically consistent (Mann-Whitney U test, P > 0.05) with a mean relative error being 0.09 % and 0.24 %, showcasing a promising applicability for clinical application.
基于san -小波循环gan的腹部CT合成中解剖结构增强和组织细节保存。
从现有的未配对的MR图像生成CT图像最近成为放射治疗计划(RTP)的一个有希望的目标,然而结果的结构和细节准确性不理想仍然是其临床应用的一个挑战。为了解决这个问题,本研究提出了一种称为结构自适应归一化小波(san -小波)循环gan的无监督模型,用于非成对的mr - ct图像合成。该方法不仅开发了一个称为SAN的模块来保证解剖结构的完整性,而且引入了邻域细节损失(ND loss)来对不同模态之间的细节一致性进行惩罚。此外,设计了高频鉴别器和小波变换跳变连接,以保持高频组织细节。在腹部区域的实验结果表明,san_wavelet - cycleGAN对非配对mr - ct合成的有效性,均方误差(MSE)为66.38,均方根误差(RMSE)为8.07,峰值信噪比(PSNR)为25.944 dB,结构相似指数(SSlM)为0.895,混合感知相似指数(MPSIM)为0.723。与其他无监督方法(即cycleGAN, gc-, cc-和sc-cycleGAN)相比,就上述指标而言,SAN-cycleGAN的性能提高了5- 15% %。此外,合成CT与真实CT在计划靶体积(PTV-45Gy)和危险器官(肠)的剂量学分布具有统计学上的一致性(Mann-Whitney U检验,P > 0.05),平均相对误差分别为0.09 %和0.24 %,具有良好的临床应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.70
自引率
3.50%
发文量
71
审稿时长
26 days
期刊介绍: The purpose of the journal Computerized Medical Imaging and Graphics is to act as a source for the exchange of research results concerning algorithmic advances, development, and application of digital imaging in disease detection, diagnosis, intervention, prevention, precision medicine, and population health. Included in the journal will be articles on novel computerized imaging or visualization techniques, including artificial intelligence and machine learning, augmented reality for surgical planning and guidance, big biomedical data visualization, computer-aided diagnosis, computerized-robotic surgery, image-guided therapy, imaging scanning and reconstruction, mobile and tele-imaging, radiomics, and imaging integration and modeling with other information relevant to digital health. The types of biomedical imaging include: magnetic resonance, computed tomography, ultrasound, nuclear medicine, X-ray, microwave, optical and multi-photon microscopy, video and sensory imaging, and the convergence of biomedical images with other non-imaging datasets.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书