Yueyu Huang , Lu Qiang , Wenyu Xing , Tao Jiang , Yucheng He , Yuan Liu , Gaobo Zhang , Jingxian Wang , Xiaojun Song , Yifang Li
{"title":"SAN-Wavelet cycleGAN for anatomical structure reinforcement and tissue detail preservation in abdominal CT synthesis","authors":"Yueyu Huang , Lu Qiang , Wenyu Xing , Tao Jiang , Yucheng He , Yuan Liu , Gaobo Zhang , Jingxian Wang , Xiaojun Song , Yifang Li","doi":"10.1016/j.compmedimag.2025.102686","DOIUrl":null,"url":null,"abstract":"<div><div>Generating a CT image from an existing but unpaired MR image has recently become a promising objective in the radiotherapy treatment planning (RTP), whereas the unsatisfactory structure and detail accuracy of the outcome is still a challenge for its clinical application. To address this issue, this work proposed an unsupervised model called structure-adaptive normalization wavelet (SAN-Wavelet) cycleGAN for unpaired MR-to-CT image synthesis. This method not only developed a module called SAN to ensure the anatomically structural integrity, but also introduced a neighborhood detail loss (ND loss) for detail consistency penalization between different modalities. Furthermore, a high-frequency discriminator and wavelet-trans skip connection were designed to keep with the high-frequency tissue detail. Experimental findings on abdominal area demonstrated the effectiveness of SAN-Wavelet cycleGAN for unpaired MR-to-CT synthesis, with mean squared error (MSE) of 66.38, root mean squared error (RMSE) of 8.07, peak signal-to-noise ratio (PSNR) of 25.944 dB, structural similarity index (SSlM) of 0.895 and mixture perceptual similarity index (MPSIM) of 0.723. Compared to other unsupervised approaches (i.e., cycleGAN, gc-, cc-, and sc-cycleGAN), the performances of SAN-cycleGAN improved by 5–15 % in terms of the metrics above. Moreover, the dosimetric distributions of the synthesized CT and real CT in planning target volume (PTV-45Gy) and organ at risk area (bowel) were statistically consistent (Mann-Whitney U test, P > 0.05) with a mean relative error being 0.09 % and 0.24 %, showcasing a promising applicability for clinical application.</div></div>","PeriodicalId":50631,"journal":{"name":"Computerized Medical Imaging and Graphics","volume":"127 ","pages":"Article 102686"},"PeriodicalIF":5.5000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computerized Medical Imaging and Graphics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0895611125001958","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Generating a CT image from an existing but unpaired MR image has recently become a promising objective in the radiotherapy treatment planning (RTP), whereas the unsatisfactory structure and detail accuracy of the outcome is still a challenge for its clinical application. To address this issue, this work proposed an unsupervised model called structure-adaptive normalization wavelet (SAN-Wavelet) cycleGAN for unpaired MR-to-CT image synthesis. This method not only developed a module called SAN to ensure the anatomically structural integrity, but also introduced a neighborhood detail loss (ND loss) for detail consistency penalization between different modalities. Furthermore, a high-frequency discriminator and wavelet-trans skip connection were designed to keep with the high-frequency tissue detail. Experimental findings on abdominal area demonstrated the effectiveness of SAN-Wavelet cycleGAN for unpaired MR-to-CT synthesis, with mean squared error (MSE) of 66.38, root mean squared error (RMSE) of 8.07, peak signal-to-noise ratio (PSNR) of 25.944 dB, structural similarity index (SSlM) of 0.895 and mixture perceptual similarity index (MPSIM) of 0.723. Compared to other unsupervised approaches (i.e., cycleGAN, gc-, cc-, and sc-cycleGAN), the performances of SAN-cycleGAN improved by 5–15 % in terms of the metrics above. Moreover, the dosimetric distributions of the synthesized CT and real CT in planning target volume (PTV-45Gy) and organ at risk area (bowel) were statistically consistent (Mann-Whitney U test, P > 0.05) with a mean relative error being 0.09 % and 0.24 %, showcasing a promising applicability for clinical application.
期刊介绍:
The purpose of the journal Computerized Medical Imaging and Graphics is to act as a source for the exchange of research results concerning algorithmic advances, development, and application of digital imaging in disease detection, diagnosis, intervention, prevention, precision medicine, and population health. Included in the journal will be articles on novel computerized imaging or visualization techniques, including artificial intelligence and machine learning, augmented reality for surgical planning and guidance, big biomedical data visualization, computer-aided diagnosis, computerized-robotic surgery, image-guided therapy, imaging scanning and reconstruction, mobile and tele-imaging, radiomics, and imaging integration and modeling with other information relevant to digital health. The types of biomedical imaging include: magnetic resonance, computed tomography, ultrasound, nuclear medicine, X-ray, microwave, optical and multi-photon microscopy, video and sensory imaging, and the convergence of biomedical images with other non-imaging datasets.