Accuracy and Feasibility of Intraoperative Computed Tomography Navigation with a Clavicular Reference Frame in Anterior Cervical Spine Surgery: A Preliminary Report.

IF 1.6 Q3 SURGERY
Spine Surgery and Related Research Pub Date : 2025-10-09 eCollection Date: 2025-11-27 DOI:10.22603/ssrr.2025-0214
Shutaro Yamada, Sadaaki Kanayama, Tsuyoshi Kono, Shota Takenaka
{"title":"Accuracy and Feasibility of Intraoperative Computed Tomography Navigation with a Clavicular Reference Frame in Anterior Cervical Spine Surgery: A Preliminary Report.","authors":"Shutaro Yamada, Sadaaki Kanayama, Tsuyoshi Kono, Shota Takenaka","doi":"10.22603/ssrr.2025-0214","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The application of intraoperative computed tomography (CT) navigation in anterior cervical spine surgery remains limited because of challenges in securing a stable reference frame during supine positioning and the absence of reliable bony landmarks in the anterior cervical region. To overcome these limitations, we propose a novel technique involving reference frame placement on the proximal diaphysis of the clavicle and evaluate its feasibility and navigation accuracy.</p><p><strong>Technical note: </strong>Five patients (4 males, 1 female; mean age 59±15 years) underwent anterior cervical surgery for cervical ossification of the posterior longitudinal ligament (n=2), cervical disc herniation (n=2), and cervical spondylotic amyotrophy (n=1). The reference frame was affixed to the clavicle contralateral to the operating surgeon. Intraoperative CT scans were obtained using a robotic C-arm angiography system and navigation was performed via an optical surgical navigation system. Navigation accuracy was assessed in 3 planes: mediolateral (x), craniocaudal (y), and anteroposterior (z). Navigation errors (mean±standard deviation) were 0.29±0.24 mm (x), 0.47±0.31 mm (y), and 0.64±0.59 mm (z), all within clinically acceptable limits. No intraoperative or postoperative complications, including clavicle fracture, subclavian vessel injury, or supraclavicular nerve damage, were observed. Compared with previously reported techniques, this method demonstrated favorable accuracy.</p><p><strong>Conclusions: </strong>Clavicle-based reference frame placement offers high navigation accuracy and technical feasibility in anterior cervical spine surgery. Larger studies are warranted to confirm its clinical utility and safety.</p>","PeriodicalId":22253,"journal":{"name":"Spine Surgery and Related Research","volume":"9 6","pages":"698-704"},"PeriodicalIF":1.6000,"publicationDate":"2025-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12696457/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spine Surgery and Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22603/ssrr.2025-0214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/27 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The application of intraoperative computed tomography (CT) navigation in anterior cervical spine surgery remains limited because of challenges in securing a stable reference frame during supine positioning and the absence of reliable bony landmarks in the anterior cervical region. To overcome these limitations, we propose a novel technique involving reference frame placement on the proximal diaphysis of the clavicle and evaluate its feasibility and navigation accuracy.

Technical note: Five patients (4 males, 1 female; mean age 59±15 years) underwent anterior cervical surgery for cervical ossification of the posterior longitudinal ligament (n=2), cervical disc herniation (n=2), and cervical spondylotic amyotrophy (n=1). The reference frame was affixed to the clavicle contralateral to the operating surgeon. Intraoperative CT scans were obtained using a robotic C-arm angiography system and navigation was performed via an optical surgical navigation system. Navigation accuracy was assessed in 3 planes: mediolateral (x), craniocaudal (y), and anteroposterior (z). Navigation errors (mean±standard deviation) were 0.29±0.24 mm (x), 0.47±0.31 mm (y), and 0.64±0.59 mm (z), all within clinically acceptable limits. No intraoperative or postoperative complications, including clavicle fracture, subclavian vessel injury, or supraclavicular nerve damage, were observed. Compared with previously reported techniques, this method demonstrated favorable accuracy.

Conclusions: Clavicle-based reference frame placement offers high navigation accuracy and technical feasibility in anterior cervical spine surgery. Larger studies are warranted to confirm its clinical utility and safety.

Abstract Image

Abstract Image

Abstract Image

术中以锁骨为参考系的计算机断层导航在颈椎前路手术中的准确性和可行性:初步报告。
术中计算机断层扫描(CT)导航在颈椎前路手术中的应用仍然有限,因为在仰卧位时难以获得稳定的参照系,并且在颈椎前路区域缺乏可靠的骨标记。为了克服这些限制,我们提出了一种新的技术,包括在锁骨近端骨干放置参考框架,并评估其可行性和导航精度。技术说明:5例患者(男4例,女1例,平均年龄59±15岁)行颈椎前路手术治疗颈后纵韧带骨化(n=2)、颈椎间盘突出(n=2)、颈椎病型肌萎缩(n=1)。参考架固定在手术医生对侧的锁骨上。术中使用机器人c臂血管造影系统进行CT扫描,并通过光学手术导航系统进行导航。在3个平面上评估导航精度:中外侧(x)、颅侧(y)和正前方(z)。导航误差(平均值±标准差)分别为0.29±0.24 mm (x)、0.47±0.31 mm (y)和0.64±0.59 mm (z),均在临床可接受范围内。术中或术后无并发症,包括锁骨骨折、锁骨下血管损伤或锁骨上神经损伤。与先前报道的技术相比,该方法显示出良好的准确性。结论:在颈椎前路手术中,基于锁骨的参考架定位具有较高的导航精度和技术可行性。需要更大规模的研究来证实其临床应用和安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
71
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书