{"title":"Lens Radiation Exposure During Total Aortic Arch Repair With Double-Fenestrated Physician-Modified Stent Graft: A Prospective Study.","authors":"Christoph Bacri, Kheira Hireche, Pierre Alric, Ludovic Canaud","doi":"10.1177/15266028251399082","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this report is to quantify the radiation exposure of each person present in the operating room, with a focus on lens exposure, during total aortic arch repair using double-fenestrated PMEG (physician-modified endograft).</p><p><strong>Methods: </strong>Prospective, nonrandomized single-center study design. Radiation data from 22 procedures of aortic arch repair with double-fenestrated PMEG from February to June 2025 were analyzed. Patient dose information was collected by the imaging equipment. Real-time dosimetry was used to collect exposure data to the lens for the operators, first assistant, and anesthesiologist. The endpoints are overall equivalent doses and lens exposure.</p><p><strong>Results: </strong>A total of 11 patients were treated for arch aneurysm and 11 for chronic dissection. Mean body mass index (BMI) of the patient is 26.4 kg/m<sup>2</sup> (SD=3.5). Mean radiation time is 10 minutes (SD=4.4), median total radiation is 180 dGy.cm<sup>2</sup> (IQR=150), and air Kerma is 49 mGy (SD=81). Received lens doses are respectively for the main operator, the first assistant, and the anesthetist of 6.4 μSv (IQR=6.6), 0.62 μSv (IQR=0.67), and 2 μSv (IQR=2.02). Dose of iodine contrast injected was 40 mL in all patients. Radiation exposure was significantly higher when BMI was over 27 kg/m<sup>2</sup>.</p><p><strong>Conclusion: </strong>Radiation protection is a critical concern for vascular surgeons as complex endovascular procedures routinely deliver measurable radiation to the eyes. Double-fenestrated PMEG is an endovascular solution for total aortic arch repair with acceptably low radiation exposure, particularly to the lens.Clinical ImpactThis study presents the results on 22 patients treated with double-fenestrated PMEG, with prospectively collected data on radiation exposure (overall and to the lens). It suggests that total aortic arch repair is feasible with acceptably low radiation exposure to both the patient and the operating room staff (main operator, first assistant, and anesthetist), especially regarding the lens exposure.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"2858-2863"},"PeriodicalIF":1.8000,"publicationDate":"2026-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028251399082","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of this report is to quantify the radiation exposure of each person present in the operating room, with a focus on lens exposure, during total aortic arch repair using double-fenestrated PMEG (physician-modified endograft).

Methods: Prospective, nonrandomized single-center study design. Radiation data from 22 procedures of aortic arch repair with double-fenestrated PMEG from February to June 2025 were analyzed. Patient dose information was collected by the imaging equipment. Real-time dosimetry was used to collect exposure data to the lens for the operators, first assistant, and anesthesiologist. The endpoints are overall equivalent doses and lens exposure.

Results: A total of 11 patients were treated for arch aneurysm and 11 for chronic dissection. Mean body mass index (BMI) of the patient is 26.4 kg/m2 (SD=3.5). Mean radiation time is 10 minutes (SD=4.4), median total radiation is 180 dGy.cm2 (IQR=150), and air Kerma is 49 mGy (SD=81). Received lens doses are respectively for the main operator, the first assistant, and the anesthetist of 6.4 μSv (IQR=6.6), 0.62 μSv (IQR=0.67), and 2 μSv (IQR=2.02). Dose of iodine contrast injected was 40 mL in all patients. Radiation exposure was significantly higher when BMI was over 27 kg/m2.

Conclusion: Radiation protection is a critical concern for vascular surgeons as complex endovascular procedures routinely deliver measurable radiation to the eyes. Double-fenestrated PMEG is an endovascular solution for total aortic arch repair with acceptably low radiation exposure, particularly to the lens.Clinical ImpactThis study presents the results on 22 patients treated with double-fenestrated PMEG, with prospectively collected data on radiation exposure (overall and to the lens). It suggests that total aortic arch repair is feasible with acceptably low radiation exposure to both the patient and the operating room staff (main operator, first assistant, and anesthetist), especially regarding the lens exposure.

双开窗医师改良支架全主动脉弓修复术中晶状体辐射暴露:一项前瞻性研究。
目的:本报告的目的是量化手术室中每个人的辐射暴露,重点是使用双开窗PMEG(医生改良的内植体)进行全主动脉弓修复时的晶状体暴露。方法:前瞻性、非随机单中心研究设计。分析了2025年2月至6月22例双开窗PMEG主动脉弓修复术的放疗数据。通过成像设备收集患者剂量信息。实时剂量法用于收集操作者、第一助理和麻醉师在晶状体下的暴露数据。终点是总体等效剂量和透镜曝光。结果:11例为弓动脉瘤,11例为慢性夹层。患者平均体重指数(BMI)为26.4 kg/m2 (SD=3.5)。平均辐射时间为10分钟(SD=4.4),中位总辐射为180gy。cm2 (IQR=150),空气Kerma为49 mGy (SD=81)。主要操作者、第一助理和麻醉师的晶状体剂量分别为6.4 μSv (IQR=6.6)、0.62 μSv (IQR=0.67)和2 μSv (IQR=2.02)。所有患者注射碘造影剂剂量均为40 mL。当BMI超过27 kg/m2时,辐射暴露显著增加。结论:由于复杂的血管内手术通常会给眼睛带来可测量的辐射,因此辐射保护是血管外科医生关注的关键问题。双开窗PMEG是全主动脉弓修复的血管内解决方案,具有可接受的低辐射暴露,特别是对晶状体。临床影响本研究报告了22例接受双开窗PMEG治疗的患者的结果,并前瞻性地收集了辐射暴露(总体和晶状体)的数据。这表明全主动脉弓修复是可行的,对患者和手术室工作人员(主要操作员、第一助理和麻醉师)的辐射暴露都是可接受的低辐射,特别是在晶状体暴露方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书