Wear of Femoral Head Taper Connections of Contemporary Total Hip Prostheses: An Experimental Study.

IF 1.5 Q4 ENGINEERING, BIOMEDICAL
Medical Devices-Evidence and Research Pub Date : 2025-11-29 eCollection Date: 2025-01-01 DOI:10.2147/MDER.S552499
Margarida Ribeiro de Sousa, Perttu S Neuvonen, Vesa Saikko
{"title":"Wear of Femoral Head Taper Connections of Contemporary Total Hip Prostheses: An Experimental Study.","authors":"Margarida Ribeiro de Sousa, Perttu S Neuvonen, Vesa Saikko","doi":"10.2147/MDER.S552499","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Progress in the design of total hip prostheses has enhanced the long-term results of total hip arthroplasty. However, recent clinical failures have raised concerns regarding the long-term performance of taper connections. Issues at the taper connection of the femoral head can lead to implant failure and revision surgery. There is scarcity of published studies on the wear performance of contemporary femoral head taper connections in carefully controlled laboratory tests. This work aims to help remedy this shortcoming.</p><p><strong>Methods: </strong>The study comprised dynamic load frame tests and multidirectional hip joint simulator tests for two contemporary prosthesis designs with titanium alloy femoral stems and CoCr and zirconia toughened alumina (ZTA) femoral heads of 36 mm diameter and medium neck length against vitamin E stabilized, highly cross-linked polyethylene liners (n = 3). Worn surfaces were analyzed by optical and scanning electron microscopy (SEM).</p><p><strong>Results: </strong>Wear was more prominent in the inferior and distal parts of the CoCr head tapers, and these regions aligned with those of the trunnions that showed most wear. Wear marks on CoCr heads were relatively mild, indicative of fretting due to micromotion. Material displacement occurred locally without dislodged debris. ZTA heads mainly showed titanium transfer by adhesive wear. ZTA femoral heads outperformed CoCr heads regarding wear resistance and surface stability. The 12/14 tapers showed more pronounced wear and surface modifications compared with Type 1 tapers. EDX analysis confirmed the absence of adhesion between CoCr and Ti alloy, and increased oxygen percentage on worn regions.</p><p><strong>Conclusion: </strong>The wear marks were mild. No serious damage was observed. The wear behavior of the taper connections appeared satisfactory, and not a cause for concern in the short term.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":"18 ","pages":"595-613"},"PeriodicalIF":1.5000,"publicationDate":"2025-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12676789/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S552499","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Progress in the design of total hip prostheses has enhanced the long-term results of total hip arthroplasty. However, recent clinical failures have raised concerns regarding the long-term performance of taper connections. Issues at the taper connection of the femoral head can lead to implant failure and revision surgery. There is scarcity of published studies on the wear performance of contemporary femoral head taper connections in carefully controlled laboratory tests. This work aims to help remedy this shortcoming.

Methods: The study comprised dynamic load frame tests and multidirectional hip joint simulator tests for two contemporary prosthesis designs with titanium alloy femoral stems and CoCr and zirconia toughened alumina (ZTA) femoral heads of 36 mm diameter and medium neck length against vitamin E stabilized, highly cross-linked polyethylene liners (n = 3). Worn surfaces were analyzed by optical and scanning electron microscopy (SEM).

Results: Wear was more prominent in the inferior and distal parts of the CoCr head tapers, and these regions aligned with those of the trunnions that showed most wear. Wear marks on CoCr heads were relatively mild, indicative of fretting due to micromotion. Material displacement occurred locally without dislodged debris. ZTA heads mainly showed titanium transfer by adhesive wear. ZTA femoral heads outperformed CoCr heads regarding wear resistance and surface stability. The 12/14 tapers showed more pronounced wear and surface modifications compared with Type 1 tapers. EDX analysis confirmed the absence of adhesion between CoCr and Ti alloy, and increased oxygen percentage on worn regions.

Conclusion: The wear marks were mild. No serious damage was observed. The wear behavior of the taper connections appeared satisfactory, and not a cause for concern in the short term.

现代全髋关节假体股骨头锥形接头磨损的实验研究。
目的:全髋关节假体设计的进步提高了全髋关节置换术的远期疗效。然而,最近的临床失败引起了人们对锥形连接的长期性能的关注。股骨头锥形连接处的问题可导致植入失败和翻修手术。在精心控制的实验室测试中,关于当代股骨头锥形连接的磨损性能的已发表的研究很少。这项工作旨在帮助弥补这一缺点。方法:采用两种现代设计的人工髋关节(n = 3),采用钛合金股骨柄和CoCr和氧化锆增韧氧化铝(ZTA)股骨头(直径36 mm,颈长中等)与维生素E稳定的高度交联聚乙烯衬垫(n = 3)进行动态负载框架试验和多向髋关节模拟器试验。采用光学显微镜和扫描电镜对磨损表面进行了分析。结果:CoCr头锥体的下、远端磨损更为突出,且与耳轴磨损最严重的区域对齐。CoCr头部的磨损痕迹相对轻微,表明微动引起的微动。局部发生物质位移,但没有发生碎片移位。ZTA头主要表现为粘接磨损转移钛。在耐磨性和表面稳定性方面,ZTA股骨头优于CoCr股骨头。与1型锥度相比,12/14型锥度表现出更明显的磨损和表面变化。EDX分析证实,CoCr与钛合金之间没有粘附,磨损区域的氧含量增加。结论:磨损痕迹轻微。没有观察到严重的损害。锥形接头的磨损性能令人满意,短期内不需要担心。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书