Feasibility Considerations of 24-Hour Heart Rate Variability as a Wellness-Focused Biomarker

Journal of chiropractic medicine Pub Date : 2025-01-01 Epub Date: 2025-09-21 DOI:10.1016/j.jcm.2025.08.006
Charles N.R. Henderson DC, PhD , Monica Smith DC, PhD , Dale F. Johnson PhD , Phyllis K. Stein PhD
{"title":"Feasibility Considerations of 24-Hour Heart Rate Variability as a Wellness-Focused Biomarker","authors":"Charles N.R. Henderson DC, PhD ,&nbsp;Monica Smith DC, PhD ,&nbsp;Dale F. Johnson PhD ,&nbsp;Phyllis K. Stein PhD","doi":"10.1016/j.jcm.2025.08.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>The purposes of this study were to (1) evaluate heart rate variability (HRV) monitoring for assessing morning, mid-day, evening, and sleep sample periods; (2) assess study-related procedures, personnel, and physical resources available at our institution; (3) identify potential problems and solutions associated with the use of 24-hour HRV at our institution.</div></div><div><h3>Methods</h3><div>Six participants were fitted with 24-hour HRV recording devices (DMS myPatch-sl) and evaluated under 3 conditions; normal-daily-activity, treadmill-walking, and paced-deep-breathing. In addition, each participant maintained a written event-diary during the evaluation period. Tachograms for sample time periods were reported with representative Fast Fourier Transform Power Analyses.</div></div><div><h3>Results</h3><div>We found that proper ECG electrode patch placement on study participants required specific training and written instructions. The DMS Holter monitor provided good-quality data over the 24-hour period without interfering with normal daily activities. However, there was data loss for 1 hour immediately following exposure of the device to water while showering. Also, there was a need to stabilize the V5 electrode wire to minimize disconnections during sleep. Participant diaries varied considerably in useful information content.</div></div><div><h3>Conclusion</h3><div>The findings for the 6 participants in this study support the feasibility of and inform applying 24-hour HRV assessment in research studies at our institution.</div></div>","PeriodicalId":94328,"journal":{"name":"Journal of chiropractic medicine","volume":"24 1","pages":"Pages 54-61"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chiropractic medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1556370725000082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/21 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The purposes of this study were to (1) evaluate heart rate variability (HRV) monitoring for assessing morning, mid-day, evening, and sleep sample periods; (2) assess study-related procedures, personnel, and physical resources available at our institution; (3) identify potential problems and solutions associated with the use of 24-hour HRV at our institution.

Methods

Six participants were fitted with 24-hour HRV recording devices (DMS myPatch-sl) and evaluated under 3 conditions; normal-daily-activity, treadmill-walking, and paced-deep-breathing. In addition, each participant maintained a written event-diary during the evaluation period. Tachograms for sample time periods were reported with representative Fast Fourier Transform Power Analyses.

Results

We found that proper ECG electrode patch placement on study participants required specific training and written instructions. The DMS Holter monitor provided good-quality data over the 24-hour period without interfering with normal daily activities. However, there was data loss for 1 hour immediately following exposure of the device to water while showering. Also, there was a need to stabilize the V5 electrode wire to minimize disconnections during sleep. Participant diaries varied considerably in useful information content.

Conclusion

The findings for the 6 participants in this study support the feasibility of and inform applying 24-hour HRV assessment in research studies at our institution.
24小时心率变异性作为健康生物标志物的可行性考虑
目的本研究的目的是:(1)评估心率变异性(HRV)监测评估早上,中午,晚上和睡眠样本时段;(2)评估我校与研究相关的程序、人员和物质资源;(3)找出与我们机构使用24小时HRV相关的潜在问题和解决方案。方法6例受试者分别安装24小时心率记录仪(DMS myPatch-sl),并在3种情况下进行评估;正常的日常活动,跑步机行走,有节奏的深呼吸。此外,每个参与者在评估期间都保留了一份书面的事件日记。用代表性的快速傅立叶变换功率分析报告了样本时间段的行车图。结果我们发现,在研究参与者身上正确放置ECG电极贴片需要专门的培训和书面指导。DMS霍尔特监测仪在24小时内提供了高质量的数据,而不干扰正常的日常活动。但是,在淋浴时将设备暴露在水中后立即有1小时的数据丢失。此外,还需要稳定V5电极线,以尽量减少睡眠期间的断开。参与者日记的有用信息内容差异很大。结论本研究6名受试者的研究结果支持24小时HRV评估的可行性,并为在我院开展研究提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书