Goniometric and 3D Motion Analysis in Shoulder ROM Assessment: A Reliability and Agreement Study Comparing Patients With Restricted Shoulder Range of Motion to Healthy Subjects

Journal of chiropractic medicine Pub Date : 2025-01-01 Epub Date: 2025-11-09 DOI:10.1016/j.jcm.2025.08.015
Sezen Karaşin MSc , Yılmaz Yıldırım MSc , Kadriye Tombak PhD , İlhan Sezer MD , Özkan Köse MD , Umut Özsoy PhD
{"title":"Goniometric and 3D Motion Analysis in Shoulder ROM Assessment: A Reliability and Agreement Study Comparing Patients With Restricted Shoulder Range of Motion to Healthy Subjects","authors":"Sezen Karaşin MSc ,&nbsp;Yılmaz Yıldırım MSc ,&nbsp;Kadriye Tombak PhD ,&nbsp;İlhan Sezer MD ,&nbsp;Özkan Köse MD ,&nbsp;Umut Özsoy PhD","doi":"10.1016/j.jcm.2025.08.015","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>This study aimed to examine the reliability and agreement of goniometric measurements in assessing the range of motion (ROM) within the shoulder joint utilizing a 3D marker-based motion analysis system.</div></div><div><h3>Methods</h3><div>The study comprised 30 healthy volunteers and 35 patients diagnosed with unilateral restricted shoulder range of motion (ROM). Agreement analysis was conducted using Bland–Altman methods, while intra- and interobserver reliability for flexion, abduction, internal rotation, and external rotation measurements was assessed using the Intraclass Correlation Coefficient (ICC).</div></div><div><h3>Results</h3><div>When goniometric measurements were compared with the 3D method, ICC values in the patient group were found to be 0.85 for flexion, 0.81 for abduction, 0.80 for external rotation, and 0.74 for internal rotation. In healthy individuals, the values were found to be 0.80, 0.90, 0.56, and 0.69. Additionally, all measurements fell within acceptable limits of agreement, with no significant differences in measurement biases, except for internal rotation.</div></div><div><h3>Conclusion</h3><div>This study highlights that the goniometer exhibited higher reliability when assessing movements with larger ROM, particularly within heterogeneous groups like those with injured shoulders. However, its reliability decreased when used in homogeneous groups, such as healthy individuals, especially when evaluating movements with narrower ROM, such as rotations. These findings emphasize the need for a nuanced interpretation of results in clinical and research settings when assessing shoulder joint mobility.</div></div>","PeriodicalId":94328,"journal":{"name":"Journal of chiropractic medicine","volume":"24 1","pages":"Pages 328-336"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chiropractic medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1556370725000185","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/9 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

This study aimed to examine the reliability and agreement of goniometric measurements in assessing the range of motion (ROM) within the shoulder joint utilizing a 3D marker-based motion analysis system.

Methods

The study comprised 30 healthy volunteers and 35 patients diagnosed with unilateral restricted shoulder range of motion (ROM). Agreement analysis was conducted using Bland–Altman methods, while intra- and interobserver reliability for flexion, abduction, internal rotation, and external rotation measurements was assessed using the Intraclass Correlation Coefficient (ICC).

Results

When goniometric measurements were compared with the 3D method, ICC values in the patient group were found to be 0.85 for flexion, 0.81 for abduction, 0.80 for external rotation, and 0.74 for internal rotation. In healthy individuals, the values were found to be 0.80, 0.90, 0.56, and 0.69. Additionally, all measurements fell within acceptable limits of agreement, with no significant differences in measurement biases, except for internal rotation.

Conclusion

This study highlights that the goniometer exhibited higher reliability when assessing movements with larger ROM, particularly within heterogeneous groups like those with injured shoulders. However, its reliability decreased when used in homogeneous groups, such as healthy individuals, especially when evaluating movements with narrower ROM, such as rotations. These findings emphasize the need for a nuanced interpretation of results in clinical and research settings when assessing shoulder joint mobility.
肩关节活动度评估中的角度测量和三维运动分析:一项比较肩关节活动度受限患者与健康受试者的可靠性和一致性研究
目的:本研究旨在利用基于3D标记的运动分析系统来评估肩关节内运动范围(ROM)的角度测量的可靠性和一致性。方法本研究纳入30名健康志愿者和35名单侧肩关节活动受限(ROM)患者。使用Bland-Altman方法进行一致性分析,而使用类内相关系数(ICC)评估屈曲、外展、内旋和外旋测量的观察者内部和观察者之间的可靠性。结果与3D方法比较,患者组屈曲时ICC值为0.85,外展时为0.81,外旋时为0.80,内旋时为0.74。在健康个体中,该值分别为0.80、0.90、0.56和0.69。此外,除内旋外,所有测量结果均在可接受的一致范围内,测量偏差无显著差异。结论:本研究强调,在评估关节活动度较大的运动时,角计表现出更高的可靠性,特别是在肩部受伤的异质群体中。然而,当在同质人群(如健康个体)中使用时,其可靠性降低,特别是在评估ROM较窄的运动(如旋转)时。这些发现强调在评估肩关节活动度时,需要对临床和研究结果进行细致入微的解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书