Fully automated gait analysis with earables: Evaluation of an End2End pipeline with hearing-aid integrated accelerometers.

Ann-Kristin Seifer, Lukas Jahnel, Arne Kuderle, Ronny Hannemann, Bjoern M Eskofier
{"title":"Fully automated gait analysis with earables: Evaluation of an End2End pipeline with hearing-aid integrated accelerometers.","authors":"Ann-Kristin Seifer, Lukas Jahnel, Arne Kuderle, Ronny Hannemann, Bjoern M Eskofier","doi":"10.1109/EMBC58623.2025.11254014","DOIUrl":null,"url":null,"abstract":"<p><p>Earables, due to their unobtrusive and lightweight nature, are increasingly being recognized for their potential in estimating digital biomarkers, yet their application in gait analysis (GA) remains limited because comprehensive analytic tools are missing. Existing ear-worn systems have primarily addressed isolated aspects such as gait classification, stride time, or step length estimation, lacking a full end-to-end pipeline. Such pipelines are essential for efficient and automated workflows and real-world applications. This work presents a complete end-to-end GA pipeline for ear-worn accelerometers incorporating multiple algorithms to process raw sensor signals into spatio-temporal parameters. This multi-step approach includes gait sequence detection, event identification, and parameter estimation. We introduce a novel gait sequence detector (GSD) that automatically detects regions of interest in continuous recordings. The integrated spatio-temporal algorithms have already been validated in an isolated setting as part of a previous evaluation study. Using a dataset with three walking speeds and foot-worn IMUs as references, the GSD effectively detects 91 % of gait sequences. The pipeline achieves stride time and SL errors of around 4 % and a gait velocity error of 5.7 %, consistent with prior evaluation for the individual isolated steps. To our knowledge, this is the first end-to-end GA pipeline for earables. Furthermore, the pipeline was released as open-source toolbox (https://github.com/mad-lab-fau/eargait), to facilitate research access and reusability. Our work lays the foundation for automated, continuous, and long-term mobility assessment in home environments using lightweight, unobtrusive earables.</p>","PeriodicalId":72237,"journal":{"name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","volume":"2025 ","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC58623.2025.11254014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Earables, due to their unobtrusive and lightweight nature, are increasingly being recognized for their potential in estimating digital biomarkers, yet their application in gait analysis (GA) remains limited because comprehensive analytic tools are missing. Existing ear-worn systems have primarily addressed isolated aspects such as gait classification, stride time, or step length estimation, lacking a full end-to-end pipeline. Such pipelines are essential for efficient and automated workflows and real-world applications. This work presents a complete end-to-end GA pipeline for ear-worn accelerometers incorporating multiple algorithms to process raw sensor signals into spatio-temporal parameters. This multi-step approach includes gait sequence detection, event identification, and parameter estimation. We introduce a novel gait sequence detector (GSD) that automatically detects regions of interest in continuous recordings. The integrated spatio-temporal algorithms have already been validated in an isolated setting as part of a previous evaluation study. Using a dataset with three walking speeds and foot-worn IMUs as references, the GSD effectively detects 91 % of gait sequences. The pipeline achieves stride time and SL errors of around 4 % and a gait velocity error of 5.7 %, consistent with prior evaluation for the individual isolated steps. To our knowledge, this is the first end-to-end GA pipeline for earables. Furthermore, the pipeline was released as open-source toolbox (https://github.com/mad-lab-fau/eargait), to facilitate research access and reusability. Our work lays the foundation for automated, continuous, and long-term mobility assessment in home environments using lightweight, unobtrusive earables.

可穿戴设备的全自动步态分析:带有助听器集成加速度计的End2End管道的评估。
由于其不显眼和轻便的特性,可穿戴设备在估计数字生物标志物方面的潜力越来越得到认可,但由于缺乏全面的分析工具,它们在步态分析(GA)中的应用仍然有限。现有的耳戴式系统主要解决孤立的方面,如步态分类、步频或步长估计,缺乏完整的端到端管道。这样的管道对于高效和自动化的工作流和实际应用程序是必不可少的。这项工作提出了一个完整的端到端遗传算法管道,用于耳戴式加速度计,结合多种算法将原始传感器信号处理成时空参数。该方法包括步态序列检测、事件识别和参数估计。我们介绍了一种新的步态序列检测器(GSD),它可以自动检测连续记录中感兴趣的区域。作为先前评估研究的一部分,综合时空算法已经在一个孤立的环境中得到验证。使用具有三种行走速度的数据集和足部imu作为参考,GSD有效检测91%的步态序列。该管道的步幅时间和步态误差约为4%,步态速度误差约为5.7%,与先前对单个孤立步骤的评估一致。据我们所知,这是首个面向可穿戴设备的端到端GA管道。此外,该管道作为开源工具箱(https://github.com/mad-lab-fau/eargait)发布,以促进研究访问和可重用性。我们的工作为使用轻便、不显眼的可穿戴设备在家庭环境中进行自动化、连续和长期的移动性评估奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书