Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system

IF 12.2
Green Technologies and Sustainability Pub Date : 2026-04-01 Epub Date: 2025-09-24 DOI:10.1016/j.grets.2025.100280
Noureddine Ech-cherki, Oumaima Echab, Youssef Errami, Abdellatif Obbadi, Smail Sahnoun
{"title":"Third-order nonlinear sliding-mode controller for improving the performance of a grid-connected PV system","authors":"Noureddine Ech-cherki,&nbsp;Oumaima Echab,&nbsp;Youssef Errami,&nbsp;Abdellatif Obbadi,&nbsp;Smail Sahnoun","doi":"10.1016/j.grets.2025.100280","DOIUrl":null,"url":null,"abstract":"<div><div>The performance of Photovoltaic (PV) power generation systems, using traditional Vector Current Controllers based on Proportional–Integral Action (CVC-PI), exhibits marked non-linearity and is strongly influenced by meteorological variations. Due to its robustness in the face of these challenges, Sliding Mode Control (SMC) has been widely used in this field, but SMC has certain inconveniences, notably the phenomenon of chattering and ripples in active (P) and reactive (Q) power. These limitations remain partially unresolved, even with the use of Second-order SMC (SMC-2). To address these limitations, this work proposes a robust, non-linear control based on the Third-order SMC in Dual Mode conversion (DM-SMC-3). To demonstrate the effectiveness of the proposed DM-SMC-3 control, a comparative study was carried out between DM-SMC-3, SMC-2, SMC and CVC-PI in terms of chattering reduction, dynamic response time, overshoot, P and Q power ripples and the Total Harmonic Distortion (THD) of the current injected into the electrical grid. The DM-SMC-3 is also used to guarantee Maximum Power Point Tracking (MPPT). The system is designed and simulated using Matlab/Simulink software. The simulation results demonstrated the significant contribution of the DM-SMC-3, with a 99% reduction in overshoot compared to other controllers. THD was reduced to 0.58%. The average reference tracking efficiency was 99.68%, and 99.41% under the temperature and irradiation conditions used. What is more, the DM-SMC-3 takes just 35ms to reach the Maximum Power Point (MPP). It also reduced P and Q power ripples, demonstrating the robustness of the proposed controller in the face of chattering.</div></div>","PeriodicalId":100598,"journal":{"name":"Green Technologies and Sustainability","volume":"4 2","pages":"Article 100280"},"PeriodicalIF":12.2000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Green Technologies and Sustainability","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949736125001149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The performance of Photovoltaic (PV) power generation systems, using traditional Vector Current Controllers based on Proportional–Integral Action (CVC-PI), exhibits marked non-linearity and is strongly influenced by meteorological variations. Due to its robustness in the face of these challenges, Sliding Mode Control (SMC) has been widely used in this field, but SMC has certain inconveniences, notably the phenomenon of chattering and ripples in active (P) and reactive (Q) power. These limitations remain partially unresolved, even with the use of Second-order SMC (SMC-2). To address these limitations, this work proposes a robust, non-linear control based on the Third-order SMC in Dual Mode conversion (DM-SMC-3). To demonstrate the effectiveness of the proposed DM-SMC-3 control, a comparative study was carried out between DM-SMC-3, SMC-2, SMC and CVC-PI in terms of chattering reduction, dynamic response time, overshoot, P and Q power ripples and the Total Harmonic Distortion (THD) of the current injected into the electrical grid. The DM-SMC-3 is also used to guarantee Maximum Power Point Tracking (MPPT). The system is designed and simulated using Matlab/Simulink software. The simulation results demonstrated the significant contribution of the DM-SMC-3, with a 99% reduction in overshoot compared to other controllers. THD was reduced to 0.58%. The average reference tracking efficiency was 99.68%, and 99.41% under the temperature and irradiation conditions used. What is more, the DM-SMC-3 takes just 35ms to reach the Maximum Power Point (MPP). It also reduced P and Q power ripples, demonstrating the robustness of the proposed controller in the face of chattering.
用于改善并网光伏系统性能的三阶非线性滑模控制器
采用基于比例积分作用(CVC-PI)的传统矢量电流控制器的光伏发电系统的性能表现出明显的非线性,且受气象变化的强烈影响。滑模控制(SMC)由于其面对这些挑战的鲁棒性,在该领域得到了广泛的应用,但SMC也存在一定的不便,特别是有源(P)和无功(Q)功率中的抖振和波纹现象。即使使用二阶SMC (SMC-2),这些限制仍未得到部分解决。为了解决这些限制,本工作提出了一种基于三阶双模转换SMC (DM-SMC-3)的鲁棒非线性控制。为了验证DM-SMC-3控制的有效性,对DM-SMC-3、SMC-2、SMC和CVC-PI进行了颤振抑制、动态响应时间、超调量、P和Q功率纹波以及注入电网电流的总谐波失真(THD)等方面的对比研究。DM-SMC-3还用于保证最大功率点跟踪(MPPT)。利用Matlab/Simulink软件对系统进行了设计和仿真。仿真结果证明了DM-SMC-3的显著贡献,与其他控制器相比,超调量降低了99%。THD降至0.58%。平均跟踪效率为99.68%,在温度和辐照条件下平均跟踪效率为99.41%。更重要的是,DM-SMC-3只需35ms即可达到最大功率点(MPP)。它还减少了P和Q功率波纹,证明了所提出的控制器在面对抖振时的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书