Xin Huang, Jin Shang, Yao Xiao, Wei Hou, Guangrui Mu, Daliang Li, Hua Qian, Junying Li
{"title":"Deep learning-based reconstruction improves image quality in low-dose head CT angiography.","authors":"Xin Huang, Jin Shang, Yao Xiao, Wei Hou, Guangrui Mu, Daliang Li, Hua Qian, Junying Li","doi":"10.4314/mmj.v37i2.8","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to compare the image quality of filtered back projection (FBP), adaptive statistical iterative reconstruction-Veo (ASIR-V) and the deep learning image reconstruction (DLIR) algorithms in low-dose head CT angiography (CTA).</p><p><strong>Methods: </strong>This prospective study was conducted on 25 patients undergoing head CTA using a 256-slice CT scanner. Patients received 25 mL of iodine contrast (Iopromide, 370 mg I/mL, 3.0 mL/s). Images were reconstructed using DLIR with high settings (DLIR-H) and medium settings (DLIR-M), FBP, and ASIR-V with a blending factor of 50% (ASIR-V 50%). CT values, standard deviations, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) were measured at the basal ganglia, posterior cranial fossa, center of semiovale, and middle cerebral artery. The edge rise slope (ERS) of the middle cerebral artery rim was measured to assess vessel clarity. Image noise, vessel edge definition, and overall quality were scored on a 5-point scale, while sharpness and clarity were rated on a 4-point scale.</p><p><strong>Results: </strong>FBP images exhibited the highest image noise, as reflected by SD values. DLIR, especially DLIR-H, showed superior noise reduction compared to ASIR-V 50%. SNR followed this trend: FBP < ASIR-V 50% < DLIR-M < DLIR-H. Spatial resolution, measured by ERS for vessel wall clarity, was higher in DLIR images compared to in ASIR-V 50%. DLIR outperformed conventional iterative algorithms in balancing noise reduction and edge clarity, with both DLIR-M and DLIR-H achieving better subjective scores for noise, edge definition, and sharpness than ASIR-V 50% and FBP.</p><p><strong>Conclusion: </strong>DLIR in low-dose head CTA could reduces image noise, preserve natural texture, and enhance image clarity compared with ASIR-V and FBP methods.</p>","PeriodicalId":18185,"journal":{"name":"Malawi Medical Journal","volume":"37 2","pages":"109-114"},"PeriodicalIF":0.9000,"publicationDate":"2025-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12538262/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malawi Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4314/mmj.v37i2.8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: This study aimed to compare the image quality of filtered back projection (FBP), adaptive statistical iterative reconstruction-Veo (ASIR-V) and the deep learning image reconstruction (DLIR) algorithms in low-dose head CT angiography (CTA).
Methods: This prospective study was conducted on 25 patients undergoing head CTA using a 256-slice CT scanner. Patients received 25 mL of iodine contrast (Iopromide, 370 mg I/mL, 3.0 mL/s). Images were reconstructed using DLIR with high settings (DLIR-H) and medium settings (DLIR-M), FBP, and ASIR-V with a blending factor of 50% (ASIR-V 50%). CT values, standard deviations, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) were measured at the basal ganglia, posterior cranial fossa, center of semiovale, and middle cerebral artery. The edge rise slope (ERS) of the middle cerebral artery rim was measured to assess vessel clarity. Image noise, vessel edge definition, and overall quality were scored on a 5-point scale, while sharpness and clarity were rated on a 4-point scale.
Results: FBP images exhibited the highest image noise, as reflected by SD values. DLIR, especially DLIR-H, showed superior noise reduction compared to ASIR-V 50%. SNR followed this trend: FBP < ASIR-V 50% < DLIR-M < DLIR-H. Spatial resolution, measured by ERS for vessel wall clarity, was higher in DLIR images compared to in ASIR-V 50%. DLIR outperformed conventional iterative algorithms in balancing noise reduction and edge clarity, with both DLIR-M and DLIR-H achieving better subjective scores for noise, edge definition, and sharpness than ASIR-V 50% and FBP.
Conclusion: DLIR in low-dose head CTA could reduces image noise, preserve natural texture, and enhance image clarity compared with ASIR-V and FBP methods.
期刊介绍:
Driven and guided by the priorities articulated in the Malawi National Health Research Agenda, the Malawi Medical Journal publishes original research, short reports, case reports, viewpoints, insightful editorials and commentaries that are of high quality, informative and applicable to the Malawian and sub-Saharan Africa regions. Our particular interest is to publish evidence-based research that impacts and informs national health policies and medical practice in Malawi and the broader region.
Topics covered in the journal include, but are not limited to:
- Communicable diseases (HIV and AIDS, Malaria, TB, etc.)
- Non-communicable diseases (Cardiovascular diseases, cancer, diabetes, etc.)
- Sexual and Reproductive Health (Adolescent health, education, pregnancy and abortion, STDs and HIV and AIDS, etc.)
- Mental health
- Environmental health
- Nutrition
- Health systems and health policy (Leadership, ethics, and governance)
- Community systems strengthening research
- Injury, trauma, and surgical disorders