The evolution of cardiac changes after breast cancer adjuvant radiotherapy – A six-year follow-up study

IF 3.6 3区 医学 Q3 ONCOLOGY
Mikko Moisander , Suvi Tuohinen , Heidi Lähdeaho , Heini Huhtala , Kjell Nikus , Vesa Virtanen , Pirkko-Liisa Kellokumpu-Lehtinen , Pekka Raatikainen , Tanja Skyttä
{"title":"The evolution of cardiac changes after breast cancer adjuvant radiotherapy – A six-year follow-up study","authors":"Mikko Moisander ,&nbsp;Suvi Tuohinen ,&nbsp;Heidi Lähdeaho ,&nbsp;Heini Huhtala ,&nbsp;Kjell Nikus ,&nbsp;Vesa Virtanen ,&nbsp;Pirkko-Liisa Kellokumpu-Lehtinen ,&nbsp;Pekka Raatikainen ,&nbsp;Tanja Skyttä","doi":"10.1016/j.ctro.2025.101078","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>This prospective study investigated the long-term effects of adjuvant radiotherapy (RT) on cardiac function and biomarkers in early breast cancer patients over a six-year follow-up.</div></div><div><h3>Methods</h3><div>Seventy-three women treated with RT alone, without chemotherapy, were included. Cardiac radiation doses were quantified, and echocardiography and serum biomarkers (high-sensitivity cardiac troponin T [hscTnT] and N-terminal pro-brain natriuretic peptide [proBNP]) were assessed before RT and at three- and six-years post-treatment.</div></div><div><h3>Results</h3><div>Cardiac biomarkers increased significantly during follow-up. Median hscTnT rose from 4 to 6 ng/L (p&lt;0.001), correlating with higher radiation doses to the heart in left-sided patients. ProBNP increased from 78 to 118 ng/L (p&lt;0.001). Left ventricular (LV) systolic function declined in left-sided patients: ejection fraction decreased from 65% to 60% (p=0.002), global longitudinal strain from –18% to –17% (p=0.006), and stroke volume from 74 to 67 mL (p=0.015). Diastolic dysfunction also progressed, with impairments in isovolumic relaxation time and left atrial ejection fraction. Aromatase inhibitor (AI) use and higher mean heart dose were associated with greater cardiac impairment.</div></div><div><h3>Conclusion</h3><div>Subclinical deterioration in cardiac function and elevated biomarkers were evident three years after RT and persisted at six years, suggesting permanent cardiac effects. Both radiation dose and AI therapy contributed to these changes. These findings underscore the importance of long-term cardiac monitoring and support the use of sensitive imaging and biomarkers to detect early radiotherapy-induced cardiotoxicity.</div></div>","PeriodicalId":10342,"journal":{"name":"Clinical and Translational Radiation Oncology","volume":"56 ","pages":"Article 101078"},"PeriodicalIF":3.6000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Translational Radiation Oncology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405630825001703","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

This prospective study investigated the long-term effects of adjuvant radiotherapy (RT) on cardiac function and biomarkers in early breast cancer patients over a six-year follow-up.

Methods

Seventy-three women treated with RT alone, without chemotherapy, were included. Cardiac radiation doses were quantified, and echocardiography and serum biomarkers (high-sensitivity cardiac troponin T [hscTnT] and N-terminal pro-brain natriuretic peptide [proBNP]) were assessed before RT and at three- and six-years post-treatment.

Results

Cardiac biomarkers increased significantly during follow-up. Median hscTnT rose from 4 to 6 ng/L (p<0.001), correlating with higher radiation doses to the heart in left-sided patients. ProBNP increased from 78 to 118 ng/L (p<0.001). Left ventricular (LV) systolic function declined in left-sided patients: ejection fraction decreased from 65% to 60% (p=0.002), global longitudinal strain from –18% to –17% (p=0.006), and stroke volume from 74 to 67 mL (p=0.015). Diastolic dysfunction also progressed, with impairments in isovolumic relaxation time and left atrial ejection fraction. Aromatase inhibitor (AI) use and higher mean heart dose were associated with greater cardiac impairment.

Conclusion

Subclinical deterioration in cardiac function and elevated biomarkers were evident three years after RT and persisted at six years, suggesting permanent cardiac effects. Both radiation dose and AI therapy contributed to these changes. These findings underscore the importance of long-term cardiac monitoring and support the use of sensitive imaging and biomarkers to detect early radiotherapy-induced cardiotoxicity.

Abstract Image

乳腺癌辅助放疗后心脏变化的演变-一项为期六年的随访研究
本前瞻性研究通过6年的随访研究了辅助放疗(RT)对早期乳腺癌患者心功能和生物标志物的长期影响。方法纳入73例仅接受放射治疗,未进行化疗的妇女。量化心脏辐射剂量,并在放疗前和治疗后3年和6年评估超声心动图和血清生物标志物(高敏心肌肌钙蛋白T [hscTnT]和n端前脑利钠肽[proBNP])。结果随访期间心脏生物标志物显著升高。中位hscTnT从4纳克/升上升到6纳克/升(p<0.001),与左脑患者较高的心脏辐射剂量相关。ProBNP从78 ng/L增加到118 ng/L (p<0.001)。左侧患者左室(LV)收缩功能下降:射血分数从65%下降到60% (p=0.002),总纵向应变从-18%下降到-17% (p=0.006),卒中容量从74下降到67 mL (p=0.015)。舒张功能障碍也有进展,等容舒张时间和左心房射血分数受损。芳香酶抑制剂(AI)的使用和较高的平均心脏剂量与更大的心脏损害相关。结论放疗后3年心功能亚临床恶化和生物标志物升高明显,并持续至6年,提示永久性心脏影响。放射剂量和人工智能治疗都对这些变化有贡献。这些发现强调了长期心脏监测的重要性,并支持使用敏感成像和生物标志物来检测早期放疗引起的心脏毒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical and Translational Radiation Oncology
Clinical and Translational Radiation Oncology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.30
自引率
3.20%
发文量
114
审稿时长
40 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书