Anion Exchange Membrane Water Electrolysis Using a Catalyst-Coated Membrane Cathode.

ACS electrochemistry Pub Date : 2025-09-25 eCollection Date: 2025-11-06 DOI:10.1021/acselectrochem.5c00280
Habin Park, Shane Harris, Paul A Kohl
{"title":"Anion Exchange Membrane Water Electrolysis Using a Catalyst-Coated Membrane Cathode.","authors":"Habin Park, Shane Harris, Paul A Kohl","doi":"10.1021/acselectrochem.5c00280","DOIUrl":null,"url":null,"abstract":"<p><p>A catalyst-coated membrane (CCM) approach to electrode fabrication for high pH water electrolysis offers enhanced interfacial contact between the catalyst layer and the membrane surface in comparison to the catalyst-coated substrate (CCS) electrode configuration. The CCM facilitates enhanced ionic and water transport between the cathode and the anion exchange membrane (AEM). This advantage is particularly significant with AEM water electrolysis (compared to proton exchange membrane water electrolysis) because the cathode typically operates under dry conditions and relies solely on diffusive water transport across the AEM from the liquid-fed anode. This study presents a direct performance comparison between CCS and CCM cathode configurations using identical hydrogen evolution reaction (HER) catalysts and other components. The use of a pseudo-reference electrode integrated into the membrane electrode assembly enabled detailed analysis of the CCM cathode polarization behavior. Surface characterization provided insight into the degradation mechanisms associated with the CCM configuration. Optimization of the cathode ionomer cross-link density improved both the cathode polarization performance and the electrolysis device durability. Further optimization of the HER catalyst loading in the CCM cathode resulted in additional gains in the electrolysis efficiency. Collectively, these findings offer valuable guidance for the design and fabrication of high-performance, durable AEM electrolysis CCMs.</p>","PeriodicalId":520400,"journal":{"name":"ACS electrochemistry","volume":"1 11","pages":"2495-2502"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12598701/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS electrochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1021/acselectrochem.5c00280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/6 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A catalyst-coated membrane (CCM) approach to electrode fabrication for high pH water electrolysis offers enhanced interfacial contact between the catalyst layer and the membrane surface in comparison to the catalyst-coated substrate (CCS) electrode configuration. The CCM facilitates enhanced ionic and water transport between the cathode and the anion exchange membrane (AEM). This advantage is particularly significant with AEM water electrolysis (compared to proton exchange membrane water electrolysis) because the cathode typically operates under dry conditions and relies solely on diffusive water transport across the AEM from the liquid-fed anode. This study presents a direct performance comparison between CCS and CCM cathode configurations using identical hydrogen evolution reaction (HER) catalysts and other components. The use of a pseudo-reference electrode integrated into the membrane electrode assembly enabled detailed analysis of the CCM cathode polarization behavior. Surface characterization provided insight into the degradation mechanisms associated with the CCM configuration. Optimization of the cathode ionomer cross-link density improved both the cathode polarization performance and the electrolysis device durability. Further optimization of the HER catalyst loading in the CCM cathode resulted in additional gains in the electrolysis efficiency. Collectively, these findings offer valuable guidance for the design and fabrication of high-performance, durable AEM electrolysis CCMs.

阴离子交换膜电解水的催化膜阴极。
一种用于高pH水电解的催化剂涂覆膜(CCM)电极制造方法与催化剂涂覆基板(CCS)电极配置相比,增强了催化剂层和膜表面之间的界面接触。CCM促进了阴极和阴离子交换膜(AEM)之间离子和水的增强传输。这一优势在AEM水电解中尤为显著(与质子交换膜水电解相比),因为阴极通常在干燥条件下工作,并且完全依赖于从液体供给的阳极穿过AEM的扩散输水。本研究采用相同的析氢反应(HER)催化剂和其他组分,对CCS和CCM阴极构型进行了直接性能比较。利用集成在膜电极组件中的伪参考电极,可以详细分析CCM阴极极化行为。表面表征提供了深入了解与CCM结构相关的降解机制。优化阴极离聚体交联密度既提高了阴极极化性能,又提高了电解装置的耐用性。在CCM阴极中进一步优化HER催化剂负载,导致电解效率的额外增益。总的来说,这些发现为高性能、耐用的AEM电解ccm的设计和制造提供了有价值的指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书