{"title":"[Lesion detection in optical coherence tomography based on lightweight convolutional neural networks].","authors":"H Z Cheng, X Wang, X R Ning, Y D Shen, S W Kang, S L Li, J Zhong","doi":"10.3760/cma.j.cn112142-20241130-00544","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To achieve automated lesion detection in optical coherence tomography (OCT) images based on a lightweight convolutional neural network architecture. <b>Methods:</b> This retrospective study employed deep learning to construct a lightweight lesion identification model using OCT images from Sichuan Provincial People's Hospital alongside datasets including OCT-C8, OCT-2017, and HD-OCT of MH. Model performance evaluation comprised two stages: firstly, testing on four independent external validation sets to assess the model's generalisability and accuracy; secondly, employing a confidence interval overlap comparison method to evaluate the classification performance of ophthalmologists at different levels of clinical experience (two per level) against the model, thereby determining the clinical experience level corresponding to the model's medical proficiency. <b>Results:</b> The model achieved an accuracy of 93.41% (47 054/50 374) on the validation set, with an F1 score of 88.18% (44 419/50 374) and a recall rate of 86.42% (43 533/50 374). The area under the receiver operating characteristic curve was 99.31% (50 026/50 374), with precision at 91.48% (46 082/50 374) and specificity at 99.1% (49 921/50 374). For nine categories of OCT images, namely neovascularisation, posterior vitreous detachment, epiretinal membrane, macular hole, macular schisis, subretinal fluid, normal image, vitreomacular traction, and obscured image, the precision rates were 97.48% (16 873/17 310), 90.99% (3 039/3 340), 97.62% (1 325/1 358), 97.91% (2 185/2 232), 79.23% (4 961/6 262), 81.47% (1 594/1 957), 90.55% (17 744/19 596), 88.08% (237/269), and 99.95% (19 520/19 530), respectively. The model achieved an average accuracy of 89.9% on the external validation set, whereas junior physicians demonstrated an accuracy of 74% (95%<i>CI</i>: 61.84%~86.16%) in interpreting OCT images, and that of mid-level physicians was 88% (95%<i>CI</i>: 78.99%~97.01%), indicating the model's performance approached that of mid-level physicians. <b>Conclusions:</b> This study marks the first successful implementation of automated recognition across nine categories of OCT images. Its clinical performance has preliminarily attained the level of a mid-career physician, and it can be deployed locally within healthcare settings to enhance diagnostic efficiency and accuracy.</p>","PeriodicalId":39688,"journal":{"name":"中华眼科杂志","volume":"61 11","pages":"896-903"},"PeriodicalIF":0.0000,"publicationDate":"2025-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华眼科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112142-20241130-00544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To achieve automated lesion detection in optical coherence tomography (OCT) images based on a lightweight convolutional neural network architecture. Methods: This retrospective study employed deep learning to construct a lightweight lesion identification model using OCT images from Sichuan Provincial People's Hospital alongside datasets including OCT-C8, OCT-2017, and HD-OCT of MH. Model performance evaluation comprised two stages: firstly, testing on four independent external validation sets to assess the model's generalisability and accuracy; secondly, employing a confidence interval overlap comparison method to evaluate the classification performance of ophthalmologists at different levels of clinical experience (two per level) against the model, thereby determining the clinical experience level corresponding to the model's medical proficiency. Results: The model achieved an accuracy of 93.41% (47 054/50 374) on the validation set, with an F1 score of 88.18% (44 419/50 374) and a recall rate of 86.42% (43 533/50 374). The area under the receiver operating characteristic curve was 99.31% (50 026/50 374), with precision at 91.48% (46 082/50 374) and specificity at 99.1% (49 921/50 374). For nine categories of OCT images, namely neovascularisation, posterior vitreous detachment, epiretinal membrane, macular hole, macular schisis, subretinal fluid, normal image, vitreomacular traction, and obscured image, the precision rates were 97.48% (16 873/17 310), 90.99% (3 039/3 340), 97.62% (1 325/1 358), 97.91% (2 185/2 232), 79.23% (4 961/6 262), 81.47% (1 594/1 957), 90.55% (17 744/19 596), 88.08% (237/269), and 99.95% (19 520/19 530), respectively. The model achieved an average accuracy of 89.9% on the external validation set, whereas junior physicians demonstrated an accuracy of 74% (95%CI: 61.84%~86.16%) in interpreting OCT images, and that of mid-level physicians was 88% (95%CI: 78.99%~97.01%), indicating the model's performance approached that of mid-level physicians. Conclusions: This study marks the first successful implementation of automated recognition across nine categories of OCT images. Its clinical performance has preliminarily attained the level of a mid-career physician, and it can be deployed locally within healthcare settings to enhance diagnostic efficiency and accuracy.

[基于轻量级卷积神经网络的光学相干断层成像损伤检测]。
目的:实现基于轻量级卷积神经网络架构的光学相干断层扫描(OCT)图像病灶自动检测。方法:采用回顾性研究方法,利用四川省人民医院OCT图像,结合OCT- c8、OCT-2017和MH -OCT数据集构建轻量级病变识别模型。模型性能评估分为两个阶段:首先,在四个独立的外部验证集上进行测试,以评估模型的通用性和准确性;其次,采用置信区间重叠比较法对模型评价不同临床经验水平(每级2名)的眼科医生的分类表现,从而确定与模型的医疗熟练程度相对应的临床经验水平。结果:该模型在验证集上的准确率为93.41% (47 054/50 374),F1分数为88.18%(44 419/50 374),召回率为86.42%(43 533/50 374)。受试者工作特征曲线下面积为99.31%(50 026/50 374),精密度为91.48%(46 082/50 374),特异性为99.1%(49 921/50 374)。对新生血管、玻璃体后脱离、视网膜前膜、黄斑裂孔、黄斑裂片、视网膜下液、正常影像、玻璃体黄斑拖着、模糊影像9类OCT图像,准确率分别为97.48%(16 873/17 310)、90.99%(3 039/3 340)、97.62%(1 325/1 358)、97.91%(2 186 /2 232)、79.23%(4 961/6 262)、81.47%(1 594/1 957)、90.55%(17 744/19 596)、88.08%(237/269)、99.95%(19 520/19 530)。模型在外部验证集上的平均准确率为89.9%,而初级医生的OCT图像解释准确率为74% (95%CI: 61.84%~86.16%),中级医生的准确率为88% (95%CI: 78.99%~97.01%),表明模型的性能接近中级医生的水平。结论:本研究首次成功实现了九类OCT图像的自动识别。其临床表现已初步达到职业生涯中期医生的水平,可在当地医疗机构部署,以提高诊断效率和准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
中华眼科杂志
中华眼科杂志 Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
12700
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书