Braden G. Keil BAppSc (Chiropractic), MChiroSc (Paediatrics), FICC, FACCP, Christian J. Fludder BChiroSc, MChiropractic, DACCP
{"title":"Forces Recorded in Manual Therapy Techniques Applied to a Mannequin Simulating A 3- to 4-Month-Old Infant","authors":"Braden G. Keil BAppSc (Chiropractic), MChiroSc (Paediatrics), FICC, FACCP, Christian J. Fludder BChiroSc, MChiropractic, DACCP","doi":"10.1016/j.jmpt.2025.10.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>The purpose of this study was to record preload force, peak force, and time from preload to peak force used with 4 manipulation techniques in a simulated 3- to 4-month-old infant.</div></div><div><h3>Methods</h3><div>The project recorded 4 scenarios involving spinal manipulation applied to a mannequin comparable with a 3- to 4-month-old infant by 2 postgraduate trained and experienced practitioners and educators in pediatric spinal manipulation and mobilization. Results for preload force, peak force, time to peak, and rate of force application were determined.</div></div><div><h3>Results</h3><div>Preload force was less than 10 N in the majority of scenarios. Average peak force in 3 cervical spine scenarios ranged from 35.2 to 79.9 N. Sacral data recorded an average peak force of 34.9 to 41.2 N with a standard distribution of 3.6 to 7.1 N. The time to peak force recorded for the 4 scenarios were under 110 ms. The rate of force production for all but 1 scenario was in excess of 300 N/s. Intrapractitioner data analysis demonstrated peak forces were not significantly different across 3 scenarios, with interpractitioner data not significantly different across 2 scenarios.</div></div><div><h3>Conclusion</h3><div>Average peak forces recorded were similar to those previously reported. Time to peak recordings were typically under 100 ms and rate of force application above 300 N/s; within the optimal range for muscle spindle receptor and Golgi tendon organ activation. Further research into forces used across the pediatric age ranges is needed.</div></div>","PeriodicalId":16132,"journal":{"name":"Journal of Manipulative and Physiological Therapeutics","volume":"48 6","pages":"Pages 689-697"},"PeriodicalIF":1.4000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Manipulative and Physiological Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0161475425000296","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/11 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
The purpose of this study was to record preload force, peak force, and time from preload to peak force used with 4 manipulation techniques in a simulated 3- to 4-month-old infant.
Methods
The project recorded 4 scenarios involving spinal manipulation applied to a mannequin comparable with a 3- to 4-month-old infant by 2 postgraduate trained and experienced practitioners and educators in pediatric spinal manipulation and mobilization. Results for preload force, peak force, time to peak, and rate of force application were determined.
Results
Preload force was less than 10 N in the majority of scenarios. Average peak force in 3 cervical spine scenarios ranged from 35.2 to 79.9 N. Sacral data recorded an average peak force of 34.9 to 41.2 N with a standard distribution of 3.6 to 7.1 N. The time to peak force recorded for the 4 scenarios were under 110 ms. The rate of force production for all but 1 scenario was in excess of 300 N/s. Intrapractitioner data analysis demonstrated peak forces were not significantly different across 3 scenarios, with interpractitioner data not significantly different across 2 scenarios.
Conclusion
Average peak forces recorded were similar to those previously reported. Time to peak recordings were typically under 100 ms and rate of force application above 300 N/s; within the optimal range for muscle spindle receptor and Golgi tendon organ activation. Further research into forces used across the pediatric age ranges is needed.
期刊介绍:
The Journal of Manipulative and Physiological Therapeutics (JMPT) is an international and interdisciplinary journal dedicated to the advancement of conservative health care principles and practices. The JMPT is the premier biomedical publication in the chiropractic profession and publishes peer reviewed, research articles and the Journal''s editorial board includes leading researchers from around the world.
The Journal publishes original primary research and review articles of the highest quality in relevant topic areas. The JMPT addresses practitioners and researchers needs by adding to their clinical and basic science knowledge and by informing them about relevant issues that influence health care practices.