{"title":"Osteogenic Potential of Sr/Zn-Doped Nano Hydroxyapatite Coated Dental Implants: A Systematic Review.","authors":"Meghan Ranjan Singh, Saravanan Sekaran, Revathi Duraisamy, Suresh Bhat Venugopalan, Dhanraj Ganapathy","doi":"10.1615/JLongTermEffMedImplants.2025057782","DOIUrl":null,"url":null,"abstract":"<p><p>A novel approach to augmenting the osteogenic properties of nano-hydroxyapatite (nHA) is doping it with bioactive ions such as strontium (Sr) and zinc (Zn). The incorporation of Sr and Zn into the nano-hydroxyapatite structure enhances its bioactivity, providing a more favorable environment for osteogenesis. The aim of this review is to evaluate the osteogenic potential of Sr/Zn-doped nano-hydroxyapatite coatings on dental implants, focusing on their effects on osseointegration and bone regeneration. A comprehensive literature search was conducted to identify relevant studies. The following databases were systematically searched: PubMed, Scopus, Web of Science, Embase, and the Cochrane Library through September 2024. The search was designed to capture a wide range of studies from biomedical, clinical, and materials science. This systematic review initially identified 16 studies, with 6 excluded after screening for relevance. Of the 10 remaining, one was further excluded for not meeting criteria. Nine studies were included in the final analysis, out of which 4 were animal studies and 5 were in vitro studies but heterogeneity prevented a meta-analysis. Data extraction focused on study details, mechanisms, in vitro and in vivo results, and conclusions. Results indicated that Sr/ Zn-doped nHA plasma-sprayed coatings on titanium dental implants significantly enhance osteogenic potential. The collective evidence from the relevant studies shows that the benefits of Sr/Zn-doped HA materials for biomedical applications are multifaceted. They have demonstrated significant improvements in bioactivity, osseointegration, osteogenesis, antibacterial properties, and mechanical performance, making them promising candidates for a range of orthopedic, dental, and cranial implants.</p>","PeriodicalId":16125,"journal":{"name":"Journal of long-term effects of medical implants","volume":"35 4","pages":"21-35"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of long-term effects of medical implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/JLongTermEffMedImplants.2025057782","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
A novel approach to augmenting the osteogenic properties of nano-hydroxyapatite (nHA) is doping it with bioactive ions such as strontium (Sr) and zinc (Zn). The incorporation of Sr and Zn into the nano-hydroxyapatite structure enhances its bioactivity, providing a more favorable environment for osteogenesis. The aim of this review is to evaluate the osteogenic potential of Sr/Zn-doped nano-hydroxyapatite coatings on dental implants, focusing on their effects on osseointegration and bone regeneration. A comprehensive literature search was conducted to identify relevant studies. The following databases were systematically searched: PubMed, Scopus, Web of Science, Embase, and the Cochrane Library through September 2024. The search was designed to capture a wide range of studies from biomedical, clinical, and materials science. This systematic review initially identified 16 studies, with 6 excluded after screening for relevance. Of the 10 remaining, one was further excluded for not meeting criteria. Nine studies were included in the final analysis, out of which 4 were animal studies and 5 were in vitro studies but heterogeneity prevented a meta-analysis. Data extraction focused on study details, mechanisms, in vitro and in vivo results, and conclusions. Results indicated that Sr/ Zn-doped nHA plasma-sprayed coatings on titanium dental implants significantly enhance osteogenic potential. The collective evidence from the relevant studies shows that the benefits of Sr/Zn-doped HA materials for biomedical applications are multifaceted. They have demonstrated significant improvements in bioactivity, osseointegration, osteogenesis, antibacterial properties, and mechanical performance, making them promising candidates for a range of orthopedic, dental, and cranial implants.
一种增强纳米羟基磷灰石(nHA)成骨性能的新方法是在纳米羟基磷灰石(nHA)中掺杂生物活性离子,如锶(Sr)和锌(Zn)。锶和锌在纳米羟基磷灰石结构中的掺入增强了其生物活性,为成骨提供了更有利的环境。本文综述了锶/锌掺杂纳米羟基磷灰石涂层在牙种植体上的成骨潜力,重点研究了其对骨整合和骨再生的影响。我们进行了全面的文献检索,以确定相关研究。系统检索了以下数据库:PubMed, Scopus, Web of Science, Embase和Cochrane Library,截止到2024年9月。该搜索旨在捕获生物医学,临床和材料科学的广泛研究。本系统综述最初确定了16项研究,筛选相关性后排除了6项研究。在剩下的10人中,有1人因不符合标准而被进一步排除。最终分析纳入了9项研究,其中4项是动物研究,5项是体外研究,但异质性阻止了荟萃分析。数据提取的重点是研究细节、机制、体外和体内结果以及结论。结果表明,Sr/ zn掺杂nHA等离子喷涂涂层可显著增强钛牙种植体的成骨潜能。来自相关研究的集体证据表明,Sr/ zn掺杂透明质酸材料在生物医学应用中的益处是多方面的。它们在生物活性、骨整合、成骨、抗菌性能和机械性能方面都有显著的改善,使其成为骨科、牙科和颅骨植入物的有希望的候选材料。
期刊介绍:
MEDICAL IMPLANTS are being used in every organ of the human body. Ideally, medical implants must have biomechanical properties comparable to those of autogenous tissues without any adverse effects. In each anatomic site, studies of the long-term effects of medical implants must be undertaken to determine accurately the safety and performance of the implants. Today, implant surgery has become an interdisciplinary undertaking involving a number of skilled and gifted specialists. For example, successful cochlear implants will involve audiologists, audiological physicians, speech and language therapists, otolaryngologists, nurses, neuro-otologists, teachers of the deaf, hearing therapists, cochlear implant manufacturers, and others involved with hearing-impaired and deaf individuals.