Influence of Torque Type and Bone Loss on the Stability Quotient of Two Implants with Prostheses.

Q3 Dentistry
João Paulo do Vale Souza, Daniela Micheline Dos Santos, Clóvis Lamartine de Moraes Melo Neto, Lucas Tavares Piacenza, Emily Vivianne Freitas da Silva, Lisiane Cristina Bannwart, Marcelo Coelho Goiato
{"title":"Influence of Torque Type and Bone Loss on the Stability Quotient of Two Implants with Prostheses.","authors":"João Paulo do Vale Souza, Daniela Micheline Dos Santos, Clóvis Lamartine de Moraes Melo Neto, Lucas Tavares Piacenza, Emily Vivianne Freitas da Silva, Lisiane Cristina Bannwart, Marcelo Coelho Goiato","doi":"10.1615/JLongTermEffMedImplants.2025060463","DOIUrl":null,"url":null,"abstract":"<p><p>Osseointegration is related to the stability of the screw and influences the success rate of implant-supported prosthetic rehabilitation, as it promotes natural healing and effective bone formation, facilitating the preservation of the implant in the recipient site. Factors such as surgical technique, insertion torque, the type of recipient bone, and the macro- and microstructure of the implant can affect screw stability. The objective of this study is to analyze in vivo the influence of insertion torque, recipient bone type, and peri-implant bone loss on the implant stability quotient (ISQ) values of cylindrical implants with external hexagon (EH) and Morse taper (MT) connections, featuring a new surface treatment called referenced acid etching (RAE). A total of 40 implants were placed in edentulous areas following predefined inclusion and exclusion criteria. Immediately after implant placement (t0), insertion torque, resonance frequency, digital periapical radiographs, and peri-implant evaluation were recorded. Resonance frequency analysis, periapical radiographs, and peri-implant evaluations were repeated after osseointegration (t1) and 180 d after rehabilitation (t2). The data obtained were statistically analyzed using specific tests for each type of analysis, with a significance level of 5%. Regarding the ISQ value at t1, it resulted in a high value, with a significant reduction at t2, for both types of connection, there was bone resorption for the HE and bone gain for the MT. The installation of the implants up to 180 d of prosthesis functionality, stability, bone gain or loss and type of bone, presented clinically acceptable conditions for all connections studied.</p>","PeriodicalId":16125,"journal":{"name":"Journal of long-term effects of medical implants","volume":"35 4","pages":"51-61"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of long-term effects of medical implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/JLongTermEffMedImplants.2025060463","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Osseointegration is related to the stability of the screw and influences the success rate of implant-supported prosthetic rehabilitation, as it promotes natural healing and effective bone formation, facilitating the preservation of the implant in the recipient site. Factors such as surgical technique, insertion torque, the type of recipient bone, and the macro- and microstructure of the implant can affect screw stability. The objective of this study is to analyze in vivo the influence of insertion torque, recipient bone type, and peri-implant bone loss on the implant stability quotient (ISQ) values of cylindrical implants with external hexagon (EH) and Morse taper (MT) connections, featuring a new surface treatment called referenced acid etching (RAE). A total of 40 implants were placed in edentulous areas following predefined inclusion and exclusion criteria. Immediately after implant placement (t0), insertion torque, resonance frequency, digital periapical radiographs, and peri-implant evaluation were recorded. Resonance frequency analysis, periapical radiographs, and peri-implant evaluations were repeated after osseointegration (t1) and 180 d after rehabilitation (t2). The data obtained were statistically analyzed using specific tests for each type of analysis, with a significance level of 5%. Regarding the ISQ value at t1, it resulted in a high value, with a significant reduction at t2, for both types of connection, there was bone resorption for the HE and bone gain for the MT. The installation of the implants up to 180 d of prosthesis functionality, stability, bone gain or loss and type of bone, presented clinically acceptable conditions for all connections studied.

扭矩类型和骨丢失对两种种植体假体稳定性商的影响。
骨整合关系到螺钉的稳定性,影响种植体支持的假体康复的成功率,因为它促进自然愈合和有效的骨形成,有利于种植体在受体部位的保存。手术技术、插入扭矩、受体骨类型以及种植体的宏观和微观结构等因素都会影响螺钉的稳定性。本研究的目的是在体内分析插入扭矩、受体骨类型和种植体周围骨丢失对外六边形(EH)和莫尔斯锥度(MT)连接圆柱形种植体种植体稳定商(ISQ)值的影响,采用一种新的表面处理称为参考酸蚀(RAE)。按照预先确定的纳入和排除标准,在无牙区放置了40个种植体。植体植入后(10),立即记录植入扭矩、共振频率、数字根尖周x线片和种植体周围评价。在骨整合后(t1)和康复后180 d (t2)重复进行共振频率分析、根尖周x线片和种植体周围评估。对获得的数据进行统计分析,采用每种分析类型的特定检验,显著性水平为5%。t1时的ISQ值较高,t2时的ISQ值显著降低,对于两种类型的连接,HE有骨吸收,MT有骨增加。植入假体的功能、稳定性、骨增加或损失和骨类型,对于所有研究的连接来说都是临床可接受的条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
46
期刊介绍: MEDICAL IMPLANTS are being used in every organ of the human body. Ideally, medical implants must have biomechanical properties comparable to those of autogenous tissues without any adverse effects. In each anatomic site, studies of the long-term effects of medical implants must be undertaken to determine accurately the safety and performance of the implants. Today, implant surgery has become an interdisciplinary undertaking involving a number of skilled and gifted specialists. For example, successful cochlear implants will involve audiologists, audiological physicians, speech and language therapists, otolaryngologists, nurses, neuro-otologists, teachers of the deaf, hearing therapists, cochlear implant manufacturers, and others involved with hearing-impaired and deaf individuals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书