Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation.

IF 2.4 Q2 Medicine
JMIR Cardio Pub Date : 2025-11-10 DOI:10.2196/78075
Hong Wang, Binbin Liu, Hui Zhang, Zheqi Zhang, Zhigeng Jin, Hao Wang, Yu-Tao Guo
{"title":"Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation.","authors":"Hong Wang, Binbin Liu, Hui Zhang, Zheqi Zhang, Zhigeng Jin, Hao Wang, Yu-Tao Guo","doi":"10.2196/78075","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Atrial fibrillation (AF) burden is associated with cardiovascular events such as stroke and heart failure. Recent advancements in photoplethysmography (PPG) technology have provided new insights into noninvasive and convenient AF burden detection.</p><p><strong>Objective: </strong>This study aimed to establish an AF burden model based on smartwatch-monitored PPG technology to track the progression of AF.</p><p><strong>Methods: </strong>This prospective pilot study (January 2024 to January 2025) at the Chinese PLA General Hospital enrolled patients with paroxysmal AF. Participants underwent simultaneous rhythm monitoring using smartwatch PPG and 24-hour Holter electrocardiogram monitoring (the gold standard). Five PPG-derived AF burden metrics were defined: (1) ratio of AF episode duration to total monitoring time (M1), (2) ratio of AF episode frequency to total measurements (M2), (3) AF episode density (M3), (4) AF episode variability (M4), and (5) proportion of rapid ventricular rate in AF episodes (>120 beats per minute; M5). Smartwatch PPG signals were collected once per minute. Sensitivity, specificity, accuracy, precision, and F1 score were used to evaluate the PPG algorithm's AF detection capability through comparison with the gold standard (24-hour Holter monitoring). The mean absolute error (MAE) and Spearman rank correlation coefficient (rs) were used to assess the correlation between the PPG-based AF burden metrics and the gold standard.</p><p><strong>Results: </strong>A total of 145 participants with paroxysmal AF (n=96, 66.2% male; mean age 63.28, SD 14.23 years) were included. Compared to the gold standard, the PPG-based AF burden model demonstrated a sensitivity of 91.5% (95% CI 87.9%-95.1%), specificity of 97.2% (95% CI 95.9%-98.5%), precision of 92.9% (95% CI 88.6%-97.3%), accuracy of 93.3% (95% CI 88.2%-98.5%), and F1 score of 90.5% (95% CI 86.3%-94.7%). The AF burden model exhibited strong discriminatory power in the test cohort (area under the curve=89.5%, 95% CI 89.4%-89.7%). For M1, the MAE for the model of AF episode duration as a proportion of total monitoring time was 0.0400 (P=.008), with a correlation coefficient (rs) of 0.8788 (P<.001). For M4, the MAE for the AF episode variability model was 3.9967 (P<.001), with a correlation coefficient (rs) of 0.7876 (P<.001). The MAE for the average real variability model was 4.6436 (P<.001), with a correlation coefficient (rs) of 0.8127 (P<.001). The MAE for the average AF change model was 0.3893 (P=.27), with a correlation coefficient (rs) of 0.7246 (P<.001).</p><p><strong>Conclusions: </strong>The PPG-based AF burden model demonstrated high concordance with the gold standard of 24-hour Holter monitoring in tracking AF episode duration and variability, providing new perspectives for exploring AF progression dynamics.</p>","PeriodicalId":14706,"journal":{"name":"JMIR Cardio","volume":"9 ","pages":"e78075"},"PeriodicalIF":2.4000,"publicationDate":"2025-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12599996/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JMIR Cardio","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2196/78075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Atrial fibrillation (AF) burden is associated with cardiovascular events such as stroke and heart failure. Recent advancements in photoplethysmography (PPG) technology have provided new insights into noninvasive and convenient AF burden detection.

Objective: This study aimed to establish an AF burden model based on smartwatch-monitored PPG technology to track the progression of AF.

Methods: This prospective pilot study (January 2024 to January 2025) at the Chinese PLA General Hospital enrolled patients with paroxysmal AF. Participants underwent simultaneous rhythm monitoring using smartwatch PPG and 24-hour Holter electrocardiogram monitoring (the gold standard). Five PPG-derived AF burden metrics were defined: (1) ratio of AF episode duration to total monitoring time (M1), (2) ratio of AF episode frequency to total measurements (M2), (3) AF episode density (M3), (4) AF episode variability (M4), and (5) proportion of rapid ventricular rate in AF episodes (>120 beats per minute; M5). Smartwatch PPG signals were collected once per minute. Sensitivity, specificity, accuracy, precision, and F1 score were used to evaluate the PPG algorithm's AF detection capability through comparison with the gold standard (24-hour Holter monitoring). The mean absolute error (MAE) and Spearman rank correlation coefficient (rs) were used to assess the correlation between the PPG-based AF burden metrics and the gold standard.

Results: A total of 145 participants with paroxysmal AF (n=96, 66.2% male; mean age 63.28, SD 14.23 years) were included. Compared to the gold standard, the PPG-based AF burden model demonstrated a sensitivity of 91.5% (95% CI 87.9%-95.1%), specificity of 97.2% (95% CI 95.9%-98.5%), precision of 92.9% (95% CI 88.6%-97.3%), accuracy of 93.3% (95% CI 88.2%-98.5%), and F1 score of 90.5% (95% CI 86.3%-94.7%). The AF burden model exhibited strong discriminatory power in the test cohort (area under the curve=89.5%, 95% CI 89.4%-89.7%). For M1, the MAE for the model of AF episode duration as a proportion of total monitoring time was 0.0400 (P=.008), with a correlation coefficient (rs) of 0.8788 (P<.001). For M4, the MAE for the AF episode variability model was 3.9967 (P<.001), with a correlation coefficient (rs) of 0.7876 (P<.001). The MAE for the average real variability model was 4.6436 (P<.001), with a correlation coefficient (rs) of 0.8127 (P<.001). The MAE for the average AF change model was 0.3893 (P=.27), with a correlation coefficient (rs) of 0.7246 (P<.001).

Conclusions: The PPG-based AF burden model demonstrated high concordance with the gold standard of 24-hour Holter monitoring in tracking AF episode duration and variability, providing new perspectives for exploring AF progression dynamics.

Abstract Image

Abstract Image

Abstract Image

基于光电容积脉搏波的房颤负荷机器学习方法:算法开发与验证。
背景:心房颤动(AF)负担与心血管事件如中风和心力衰竭有关。光电体积脉搏波(PPG)技术的最新进展为无创和方便的心房纤颤负荷检测提供了新的见解。目的:本研究旨在建立基于智能手表监测PPG技术的房颤负担模型,以跟踪房颤的进展。方法:本前瞻性试点研究(2024年1月至2025年1月)在中国人民解放军总医院招募阵发性房颤患者,参与者同时使用智能手表PPG和24小时动态心电图监测(金标准)进行心律监测。定义了5个ppg衍生的房颤负担指标:(1)房颤持续时间与总监测时间之比(M1),(2)房颤发作频率与总测量时间之比(M2),(3)房颤发作密度(M3),(4)房颤发作变异性(M4),(5)房颤发作中快速心室率的比例(>120次/分钟;M5)。每分钟收集一次智能手表的PPG信号。通过与金标准(24小时动态心电图监测)的比较,采用敏感性、特异性、准确性、精密度和F1评分来评价PPG算法的AF检测能力。使用平均绝对误差(MAE)和Spearman秩相关系数(rs)来评估基于ppg的房颤负担指标与金标准之间的相关性。结果:共纳入145例阵发性房颤患者(n=96, 66.2%为男性,平均年龄63.28岁,SD 14.23岁)。与金标准相比,基于ppg的AF负担模型的敏感性为91.5% (95% CI 87.9% ~ 95.1%),特异性为97.2% (95% CI 95.9% ~ 98.5%),精密度为92.9% (95% CI 88.6% ~ 97.3%),准确度为93.3% (95% CI 88.2% ~ 98.5%), F1评分为90.5% (95% CI 86.3% ~ 94.7%)。AF负担模型在测试队列中表现出很强的区分力(曲线下面积=89.5%,95% CI 89.4%-89.7%)。对于M1, AF发作持续时间占总监测时间的MAE为0.0400 (P= 0.008),相关系数(rs)为0.8788 (P)。结论:基于ppg的AF负担模型在跟踪AF发作持续时间和变异性方面与24小时动态心电图监测的金标准具有较高的一致性,为探讨AF进展动态提供了新的视角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JMIR Cardio
JMIR Cardio Computer Science-Computer Science Applications
CiteScore
3.50
自引率
0.00%
发文量
25
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书