Efficacy and safety of microaxial flow pump in infarct-related cardiogenic shock: a meta-analysis.

Archives of medical sciences. Atherosclerotic diseases Pub Date : 2025-09-15 eCollection Date: 2025-01-01 DOI:10.5114/amsad/209032
Rafia Hussain, Saira Bano, Hanzalah Bin Arshad, Komal Fatima, Muhammad Umar Liaqat, Aeman Waqar, Muhammad Hamza Nasim, Ayesha Javed, Saad Javed, Mfonobong Umoh, Raheel Ahmed, Mushood Ahmed, Muhammad Ayyan, Saad Ur Rahman, Mudassar Baig, Farhan Shahid
{"title":"Efficacy and safety of microaxial flow pump in infarct-related cardiogenic shock: a meta-analysis.","authors":"Rafia Hussain, Saira Bano, Hanzalah Bin Arshad, Komal Fatima, Muhammad Umar Liaqat, Aeman Waqar, Muhammad Hamza Nasim, Ayesha Javed, Saad Javed, Mfonobong Umoh, Raheel Ahmed, Mushood Ahmed, Muhammad Ayyan, Saad Ur Rahman, Mudassar Baig, Farhan Shahid","doi":"10.5114/amsad/209032","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Data regarding mechanical circulatory support with a microaxial flow pump (Impella) in patients with myocardial infarction complicated by cardiogenic shock are limited.</p><p><strong>Methods: </strong>PubMed/Medline, Embase, and the Cochrane Library were used to search for randomized controlled trials (RCTs) from inception to 16 June 2024. Risk ratios (RRs) were pooled with corresponding 95% confidence intervals (CIs) using the random effects model.</p><p><strong>Results: </strong>Four RCTs were included. The pooled analysis demonstrated a significantly reduced risk of all-cause death in patients with the use of a microaxial flow pump at 6-month follow-up (RR = 0.80; 95% CI: 0.67 to 0.97) and cardiac death (RR = 0.68; 95% CI: 0.49 to 0.94) as compared to the control group. However, the use of a microaxial flow pump was associated with a significantly increased risk of major bleeding (RR = 2.27; 95% CI: 1.21 to 4.24), limb ischemia (RR = 4.46; 95% CI: 1.31 to 15.16), and sepsis (RR = 2.01; 95% CI: 1.11 to 3.67). The risk of stroke and rehospitalizations remained comparable across the two groups.</p><p><strong>Conclusions: </strong>The use of a microaxial flow pump in infarct-related cardiogenic shock can reduce mortality at the expense of increased risk of bleeding, limb ischemia, and sepsis. Further research is required to validate our findings.</p>","PeriodicalId":516556,"journal":{"name":"Archives of medical sciences. Atherosclerotic diseases","volume":"10 ","pages":"e151-e158"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12550693/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of medical sciences. Atherosclerotic diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/amsad/209032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Data regarding mechanical circulatory support with a microaxial flow pump (Impella) in patients with myocardial infarction complicated by cardiogenic shock are limited.

Methods: PubMed/Medline, Embase, and the Cochrane Library were used to search for randomized controlled trials (RCTs) from inception to 16 June 2024. Risk ratios (RRs) were pooled with corresponding 95% confidence intervals (CIs) using the random effects model.

Results: Four RCTs were included. The pooled analysis demonstrated a significantly reduced risk of all-cause death in patients with the use of a microaxial flow pump at 6-month follow-up (RR = 0.80; 95% CI: 0.67 to 0.97) and cardiac death (RR = 0.68; 95% CI: 0.49 to 0.94) as compared to the control group. However, the use of a microaxial flow pump was associated with a significantly increased risk of major bleeding (RR = 2.27; 95% CI: 1.21 to 4.24), limb ischemia (RR = 4.46; 95% CI: 1.31 to 15.16), and sepsis (RR = 2.01; 95% CI: 1.11 to 3.67). The risk of stroke and rehospitalizations remained comparable across the two groups.

Conclusions: The use of a microaxial flow pump in infarct-related cardiogenic shock can reduce mortality at the expense of increased risk of bleeding, limb ischemia, and sepsis. Further research is required to validate our findings.

Abstract Image

Abstract Image

Abstract Image

微轴流泵治疗梗死相关性心源性休克的疗效和安全性:一项荟萃分析。
关于微轴流泵(Impella)在心肌梗死合并心源性休克患者中的机械循环支持的数据有限。方法:使用PubMed/Medline、Embase和Cochrane图书馆检索从开始到2024年6月16日的随机对照试验(rct)。采用随机效应模型将风险比(rr)与相应的95%置信区间(ci)合并。结果:纳入4项随机对照试验。合并分析表明,与对照组相比,使用微轴流泵的患者在6个月随访时的全因死亡风险(RR = 0.80; 95% CI: 0.67至0.97)和心源性死亡风险(RR = 0.68; 95% CI: 0.49至0.94)显著降低。然而,使用微轴流泵与大出血(RR = 2.27; 95% CI: 1.21至4.24)、肢体缺血(RR = 4.46; 95% CI: 1.31至15.16)和脓毒症(RR = 2.01; 95% CI: 1.11至3.67)的风险显著增加相关。卒中和再住院的风险在两组之间保持可比性。结论:在梗死相关性心源性休克中使用微轴流泵可以降低死亡率,但会增加出血、肢体缺血和败血症的风险。需要进一步的研究来验证我们的发现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书