Influence of Implant Scan Body Material and Exposure on the Accuracy of Implant Positioning in Digital Scanning

IF 3.3 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Australian dental journal Pub Date : 2026-02-26 Epub Date: 2025-10-26 DOI:10.1111/adj.70011
Cansu Bolat, Bilge Ergünbaş
{"title":"Influence of Implant Scan Body Material and Exposure on the Accuracy of Implant Positioning in Digital Scanning","authors":"Cansu Bolat,&nbsp;Bilge Ergünbaş","doi":"10.1111/adj.70011","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The purpose of this in vitro study was to evaluate the influence of implant scan body material and its exposed portion on ti-base (titanium-based) positioning accuracy.</p>\n </section>\n \n <section>\n \n <h3> Material and Methods</h3>\n \n <p>In this study, a total of 14 diagnostic casts were created using two different scan bodies in 7 subgroups, ranging from the bone level to a depth of 6 mm. The diagnostic casts were scanned using a desktop scanner (Ceramill Map 600+, Amann Girrbach, Austria) for reference. The experimental data were scanned five times with an intraoral scanner (TRIOS 5, 3Shape, Copenhagen, Denmark) in each group (<i>n</i> = 70). All scan data were transferred to CAD software (Exocad, DentalCAD 3.1 Rijeka, Darmstadt, Germany). The ti-base positions were determined after the scan body image matching. The ti-base position deviations were analysed in three dimensions. A two-way ANOVA test was used to compare data according to depth and material variables.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The depth factor (<i>p</i> = 0.000) and the interaction between depth and material (<i>p</i> = 0.006) had statistically significant effects on the accuracy of ti-base positioning, whereas the material factor did not show a significant effect (<i>p</i> = 0.559).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>As the exposure of the scan bodies decreased, the obtained deviation values tended to increase for both scan body materials.</p>\n </section>\n </div>","PeriodicalId":8593,"journal":{"name":"Australian dental journal","volume":"71 1","pages":"49-58"},"PeriodicalIF":3.3000,"publicationDate":"2026-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian dental journal","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/adj.70011","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The purpose of this in vitro study was to evaluate the influence of implant scan body material and its exposed portion on ti-base (titanium-based) positioning accuracy.

Material and Methods

In this study, a total of 14 diagnostic casts were created using two different scan bodies in 7 subgroups, ranging from the bone level to a depth of 6 mm. The diagnostic casts were scanned using a desktop scanner (Ceramill Map 600+, Amann Girrbach, Austria) for reference. The experimental data were scanned five times with an intraoral scanner (TRIOS 5, 3Shape, Copenhagen, Denmark) in each group (n = 70). All scan data were transferred to CAD software (Exocad, DentalCAD 3.1 Rijeka, Darmstadt, Germany). The ti-base positions were determined after the scan body image matching. The ti-base position deviations were analysed in three dimensions. A two-way ANOVA test was used to compare data according to depth and material variables.

Results

The depth factor (p = 0.000) and the interaction between depth and material (p = 0.006) had statistically significant effects on the accuracy of ti-base positioning, whereas the material factor did not show a significant effect (p = 0.559).

Conclusions

As the exposure of the scan bodies decreased, the obtained deviation values tended to increase for both scan body materials.

数字扫描中种植体扫描体材料和暴露对种植体定位精度的影响。
目的:体外研究种植体扫描体材料及其暴露部分对钛基(钛基)定位精度的影响。材料和方法:在本研究中,使用两种不同的扫描体在7个亚组中创建了14个诊断模型,范围从骨水平到6mm深度。诊断铸件使用桌面扫描仪(Ceramill Map 600+, Amann Girrbach, Austria)进行扫描,以供参考。每组用口腔内扫描仪(TRIOS 5, 3Shape, Copenhagen, Denmark)扫描5次实验数据(n = 70)。所有扫描数据传输到CAD软件(Exocad, DentalCAD 3.1 Rijeka, Darmstadt, Germany)。扫描体像匹配后确定反基位置。对反基位置偏差进行了三维分析。采用双因素方差分析(two-way ANOVA)对深度和材料变量进行比较。结果:深度因素(p = 0.000)和深度与材料的交互作用(p = 0.006)对ti-base定位精度有显著的影响,而材料因素无显著影响(p = 0.559)。结论:随着扫描体曝光量的减少,两种扫描体材料得到的偏差值都有增加的趋势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Australian dental journal
Australian dental journal 医学-牙科与口腔外科
CiteScore
4.20
自引率
4.80%
发文量
50
审稿时长
6-12 weeks
期刊介绍: The Australian Dental Journal provides a forum for the exchange of information about new and significant research in dentistry, promoting the discipline of dentistry in Australia and throughout the world. It comprises peer-reviewed research articles as its core material, supplemented by reviews, theoretical articles, special features and commentaries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书