Preliminary evaluation of a whole blood dual-platform flow cytometry protocol for CAR-T cell quantitation: Toward accreditation and clinical routine application

IF 1.7 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Journal of immunological methods Pub Date : 2025-12-01 Epub Date: 2025-10-22 DOI:10.1016/j.jim.2025.113986
Rémi Pescarmona , Guillaume Monneret , Eleonore Micoud , Christophe Malcus , Emmanuel Bachy , Pierre Sesques , Lionel Karlin , Fabienne Venet , Morgane Gossez
{"title":"Preliminary evaluation of a whole blood dual-platform flow cytometry protocol for CAR-T cell quantitation: Toward accreditation and clinical routine application","authors":"Rémi Pescarmona ,&nbsp;Guillaume Monneret ,&nbsp;Eleonore Micoud ,&nbsp;Christophe Malcus ,&nbsp;Emmanuel Bachy ,&nbsp;Pierre Sesques ,&nbsp;Lionel Karlin ,&nbsp;Fabienne Venet ,&nbsp;Morgane Gossez","doi":"10.1016/j.jim.2025.113986","DOIUrl":null,"url":null,"abstract":"<div><div>Chimeric Antigen Receptor T-cells, commonly known as CAR-T cells, have represented a major scientific breakthrough in cancer cell therapy revolutionizing the treatment of haematological disorders. Pharmacokinetic studies highlighted the importance of peripheral blood CAR-T cell monitoring to predict therapeutic outcomes and manage side effects. This study aimed to establish and evaluate on three different flow cytometers (DxFLEX, Navios and Navios EX) the performances of a dual-platform protocol for CAR-T quantitation method using flow cytometry in a context of hospital routine use. Fresh whole blood was stained using a biotinylated CD19 or BCMA recombinant protein and a PE-coupled anti-biotin antibody. CAR-T cells were identified among CD45+ CD3+ cells after doublets elimination, using a control tube to define CAR-T positive expression threshold among T lymphocytes. Results were expressed as percentages of CAR T cells among CD3+ T lymphocytes. Optilyse C and Versalyse red blood cell lysis reagents (Beckman Coulter) gave comparable results in terms of CAR T cell percentage among T lymphocytes as well as using 0.5 μL CAR detection reagent compared to the 2 μL recommended by the manufacturer. Using this protocol, we did not observe any cross-reactivity between CD19 and BCMA CAR detection reagents or decreased signal even up to &gt;3000 circulating CAR-T cells/μL. The coefficient of variations for repeatability and intermediate precision were systematically below 10 % whatever the flow cytometer, the type of CAR reagent detection used and the proportion of circulating CAR-T cells. All three flow cytometers returned correlated and comparable results. Finally, concerning whole blood sample and stained cell storage duration, we observed a significant decreased of CAR-T percentages when staining was delayed for more than one day after sampling, and after three days of stained cells storage at 4 °C. In conclusion, we propose a dual-platform protocol for CAR-T cell enumeration which demonstrated consistent and reliable performances for BCMA and CD19 CAR-T cell quantification.</div></div>","PeriodicalId":16000,"journal":{"name":"Journal of immunological methods","volume":"545 ","pages":"Article 113986"},"PeriodicalIF":1.7000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of immunological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022175925001863","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Chimeric Antigen Receptor T-cells, commonly known as CAR-T cells, have represented a major scientific breakthrough in cancer cell therapy revolutionizing the treatment of haematological disorders. Pharmacokinetic studies highlighted the importance of peripheral blood CAR-T cell monitoring to predict therapeutic outcomes and manage side effects. This study aimed to establish and evaluate on three different flow cytometers (DxFLEX, Navios and Navios EX) the performances of a dual-platform protocol for CAR-T quantitation method using flow cytometry in a context of hospital routine use. Fresh whole blood was stained using a biotinylated CD19 or BCMA recombinant protein and a PE-coupled anti-biotin antibody. CAR-T cells were identified among CD45+ CD3+ cells after doublets elimination, using a control tube to define CAR-T positive expression threshold among T lymphocytes. Results were expressed as percentages of CAR T cells among CD3+ T lymphocytes. Optilyse C and Versalyse red blood cell lysis reagents (Beckman Coulter) gave comparable results in terms of CAR T cell percentage among T lymphocytes as well as using 0.5 μL CAR detection reagent compared to the 2 μL recommended by the manufacturer. Using this protocol, we did not observe any cross-reactivity between CD19 and BCMA CAR detection reagents or decreased signal even up to >3000 circulating CAR-T cells/μL. The coefficient of variations for repeatability and intermediate precision were systematically below 10 % whatever the flow cytometer, the type of CAR reagent detection used and the proportion of circulating CAR-T cells. All three flow cytometers returned correlated and comparable results. Finally, concerning whole blood sample and stained cell storage duration, we observed a significant decreased of CAR-T percentages when staining was delayed for more than one day after sampling, and after three days of stained cells storage at 4 °C. In conclusion, we propose a dual-platform protocol for CAR-T cell enumeration which demonstrated consistent and reliable performances for BCMA and CD19 CAR-T cell quantification.
用于CAR-T细胞定量的全血双平台流式细胞术方案的初步评估:走向认证和临床常规应用。
嵌合抗原受体t细胞,通常称为CAR-T细胞,代表了癌症细胞治疗的重大科学突破,彻底改变了血液系统疾病的治疗。药代动力学研究强调了外周血CAR-T细胞监测对预测治疗结果和管理副作用的重要性。本研究旨在建立和评估三种不同的流式细胞仪(DxFLEX, Navios和Navios EX)在医院常规使用的情况下使用流式细胞仪进行CAR-T定量方法的双平台方案的性能。用生物素化CD19或BCMA重组蛋白和pe偶联抗生物素抗体对新鲜全血进行染色。消除双链后,在CD45+ CD3+细胞中鉴定CAR-T细胞,用对照管确定T淋巴细胞中CAR-T阳性表达阈值。结果以CD3+ T淋巴细胞中CAR - T细胞的百分比表示。Optilyse C和Versalyse红细胞裂解试剂(Beckman Coulter)在T淋巴细胞中的CAR - T细胞百分比方面给出了相当的结果,并且使用0.5 μL的CAR检测试剂与制造商推荐的2 μL相比。使用该方案,我们没有观察到CD19和BCMA CAR检测试剂之间的任何交叉反应性或信号降低,甚至高达3000个循环CAR- t细胞/μL。无论使用何种流式细胞仪、CAR试剂检测类型和循环CAR- t细胞的比例,重复性和中间精度的变异系数系统地低于10 %。所有三个流式细胞仪返回相关和可比的结果。最后,关于全血样本和染色细胞的保存时间,我们观察到,当取样后染色延迟超过一天,以及在4 °C下染色细胞保存三天后,CAR-T百分比显著下降。总之,我们提出了一种CAR-T细胞计数的双平台方案,该方案在BCMA和CD19 CAR-T细胞定量方面表现出一致和可靠的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
120
审稿时长
3 months
期刊介绍: The Journal of Immunological Methods is devoted to covering techniques for: (1) Quantitating and detecting antibodies and/or antigens. (2) Purifying immunoglobulins, lymphokines and other molecules of the immune system. (3) Isolating antigens and other substances important in immunological processes. (4) Labelling antigens and antibodies. (5) Localizing antigens and/or antibodies in tissues and cells. (6) Detecting, and fractionating immunocompetent cells. (7) Assaying for cellular immunity. (8) Documenting cell-cell interactions. (9) Initiating immunity and unresponsiveness. (10) Transplanting tissues. (11) Studying items closely related to immunity such as complement, reticuloendothelial system and others. (12) Molecular techniques for studying immune cells and their receptors. (13) Imaging of the immune system. (14) Methods for production or their fragments in eukaryotic and prokaryotic cells. In addition the journal will publish articles on novel methods for analysing the organization, structure and expression of genes for immunologically important molecules such as immunoglobulins, T cell receptors and accessory molecules involved in antigen recognition, processing and presentation. Submitted full length manuscripts should describe new methods of broad applicability to immunology and not simply the application of an established method to a particular substance - although papers describing such applications may be considered for publication as a short Technical Note. Review articles will also be published by the Journal of Immunological Methods. In general these manuscripts are by solicitation however anyone interested in submitting a review can contact the Reviews Editor and provide an outline of the proposed review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书