Implementation and Evaluation of an On-Site Calibration Method for High-Voltage Testing Systems up to 600 kV

IF 4 Q1 Engineering
Ahmed S. Haiba
{"title":"Implementation and Evaluation of an On-Site Calibration Method for High-Voltage Testing Systems up to 600 kV","authors":"Ahmed S. Haiba","doi":"10.23919/CJEE.2025.000128","DOIUrl":null,"url":null,"abstract":"Technological progress has led to the development of high-voltage testing equipment with extremely high-voltage ranges potentially reaching 600 kV or higher. Such equipment cannot be calibrated using portable devices within the same range. Therefore, this study presents an on-site calibration method for high-voltage testing equipment up to 600 kV. A standard divider with a 300 kV range and a high-resolution digital multimeter for leakage current measurements are used for the calibration. To extend the calibration above 300 kV, a scale factor for the impedance method is introduced. The results demonstrate that linearity is achieved at all calibrated points, with a linearity error not exceeding 1%, indicating that the calibration can be extended to 600 kV. The findings also confirm that the unit under calibration complied with its specified accuracy. Additionally, the expanded uncertainty is estimated for each range to assess the reliability of the results. Finally, a comparison and verification tool is introduced using a normalized error tool to ensure the validity of the proposed technique. The normalized error tool results indicate that the proposed method yields satisfactory outcomes. This study establishes an on-site calibration service for high-voltage testing equipment up to 600 kV, extending the previous limit of 300 kV.","PeriodicalId":36428,"journal":{"name":"Chinese Journal of Electrical Engineering","volume":"11 3","pages":"243-252"},"PeriodicalIF":4.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11207162","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Electrical Engineering","FirstCategoryId":"1087","ListUrlMain":"https://ieeexplore.ieee.org/document/11207162/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Technological progress has led to the development of high-voltage testing equipment with extremely high-voltage ranges potentially reaching 600 kV or higher. Such equipment cannot be calibrated using portable devices within the same range. Therefore, this study presents an on-site calibration method for high-voltage testing equipment up to 600 kV. A standard divider with a 300 kV range and a high-resolution digital multimeter for leakage current measurements are used for the calibration. To extend the calibration above 300 kV, a scale factor for the impedance method is introduced. The results demonstrate that linearity is achieved at all calibrated points, with a linearity error not exceeding 1%, indicating that the calibration can be extended to 600 kV. The findings also confirm that the unit under calibration complied with its specified accuracy. Additionally, the expanded uncertainty is estimated for each range to assess the reliability of the results. Finally, a comparison and verification tool is introduced using a normalized error tool to ensure the validity of the proposed technique. The normalized error tool results indicate that the proposed method yields satisfactory outcomes. This study establishes an on-site calibration service for high-voltage testing equipment up to 600 kV, extending the previous limit of 300 kV.
600千伏以下高压测试系统现场校准方法的实施与评价
技术进步导致高压测试设备的发展,其极高的电压范围可能达到600千伏或更高。此类设备无法使用同一范围内的便携式设备进行校准。为此,本研究提出了一种600 kV以下高压检测设备的现场标定方法。校准使用了300 kV量程的标准分压器和用于泄漏电流测量的高分辨率数字万用表。为了将标定范围扩大到300kv以上,引入了阻抗法的标度因子。结果表明,所有标定点均达到线性,线性误差不超过1%,表明标定可扩展到600 kV。调查结果亦证实被校正的装置符合其指定的准确度。此外,对每个范围的扩展不确定度进行估计,以评估结果的可靠性。最后,利用归一化误差工具引入了比较和验证工具,以确保所提出技术的有效性。归一化误差工具的结果表明,所提出的方法取得了令人满意的结果。这项研究为高达600千伏的高压测试设备建立了现场校准服务,扩大了以前300千伏的限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Chinese Journal of Electrical Engineering
Chinese Journal of Electrical Engineering Energy-Energy Engineering and Power Technology
CiteScore
7.80
自引率
0.00%
发文量
621
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书