Agreement between intraocular pressure measurement using Goldmann applanation tonometry with and without fluorescein in consecutive Ghanaian patients.

Charles Darko-Takyi, Youfegan B Mathurin, Emmanuel Essien, Sandra Owusu, Osei A Yaw, Kwame O Osei, Selina Holdbrook, Andrew Owusu-Ansah
{"title":"Agreement between intraocular pressure measurement using Goldmann applanation tonometry with and without fluorescein in consecutive Ghanaian patients.","authors":"Charles Darko-Takyi, Youfegan B Mathurin, Emmanuel Essien, Sandra Owusu, Osei A Yaw, Kwame O Osei, Selina Holdbrook, Andrew Owusu-Ansah","doi":"10.4314/gmj.v59i3.4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The interchangeability of Goldmann Applanation Tonometry (GAT) with or without fluorescein requires clarification among African populations. The present study aimed to determine the agreement between IOP measurement using GAT with and without fluorescein in consecutive patients in Ghana.</p><p><strong>Design: </strong>A prospective cross-sectional clinic-based study design.</p><p><strong>Setting: </strong>The study was conducted at the Ophthalmology and Optometry units of the UCC Eye Clinic, Cape Coast, Ghana.</p><p><strong>Participants: </strong>A convenient sample of 104 consecutive patients who visited the clinic. The participants were randomised into two groups, where those in the first had their IOPs first measured without fluorescein and later with fluorescein on GAT; participants in the second group had their IOPs first measured with fluorescein and later without fluorescein after a 10-minute washout period. The central corneal thickness was measured using the Anterior Segment model of Zeiss Cirrus HD-OCT.</p><p><strong>Results: </strong>There was no agreement between the unadjusted IOP measures with and without fluorescein with GAT using the Bland Altman analysis (p < 0.0001, Lower limit: -0.9433, Upper limit: 6.8914; 95% CI = -1.6097 to -.02769). There were no statistically significant differences in gender between unadjusted IOP measurements with (Mann Whitney U test, p = 0.110) and without (Mann-Whitney U test, p = 0.083) fluorescein.</p><p><strong>Conclusion: </strong>Unadjusted IOP measurement without fluorescein was approximately 3 mmHg significantly lower than with fluorescein. We recommend practitioners maintain the gold standard GAT with fluorescein to guide accurate glaucoma diagnosis and management decision-making.</p><p><strong>Funding: </strong>Self-funded.</p>","PeriodicalId":94319,"journal":{"name":"Ghana medical journal","volume":"59 3","pages":"128-135"},"PeriodicalIF":0.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12536567/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ghana medical journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/gmj.v59i3.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The interchangeability of Goldmann Applanation Tonometry (GAT) with or without fluorescein requires clarification among African populations. The present study aimed to determine the agreement between IOP measurement using GAT with and without fluorescein in consecutive patients in Ghana.

Design: A prospective cross-sectional clinic-based study design.

Setting: The study was conducted at the Ophthalmology and Optometry units of the UCC Eye Clinic, Cape Coast, Ghana.

Participants: A convenient sample of 104 consecutive patients who visited the clinic. The participants were randomised into two groups, where those in the first had their IOPs first measured without fluorescein and later with fluorescein on GAT; participants in the second group had their IOPs first measured with fluorescein and later without fluorescein after a 10-minute washout period. The central corneal thickness was measured using the Anterior Segment model of Zeiss Cirrus HD-OCT.

Results: There was no agreement between the unadjusted IOP measures with and without fluorescein with GAT using the Bland Altman analysis (p < 0.0001, Lower limit: -0.9433, Upper limit: 6.8914; 95% CI = -1.6097 to -.02769). There were no statistically significant differences in gender between unadjusted IOP measurements with (Mann Whitney U test, p = 0.110) and without (Mann-Whitney U test, p = 0.083) fluorescein.

Conclusion: Unadjusted IOP measurement without fluorescein was approximately 3 mmHg significantly lower than with fluorescein. We recommend practitioners maintain the gold standard GAT with fluorescein to guide accurate glaucoma diagnosis and management decision-making.

Funding: Self-funded.

Abstract Image

Abstract Image

Abstract Image

在连续的加纳患者中,使用与不使用荧光素的Goldmann压眼压计测量眼压的一致性。
目的:在非洲人群中,需要澄清加或不加荧光素的Goldmann平压血压计(GAT)的互换性。本研究旨在确定加纳连续患者使用加荧光素和不加荧光素的GAT测量IOP之间的一致性。设计:前瞻性横断面临床研究设计。环境:该研究在加纳海岸角UCC眼科诊所的眼科和验光部门进行。参与者:一个方便的样本,104名连续访问诊所的患者。参与者被随机分为两组,第一组的人首先在不使用荧光素的情况下测量他们的IOPs,然后在GAT上使用荧光素;第二组的参与者在10分钟的冲洗期后,首先使用荧光素测量他们的IOPs,然后不使用荧光素。采用蔡司Cirrus HD-OCT前段模型测量角膜中央厚度。结果:使用Bland Altman分析,使用和不使用荧光素的未调整IOP测量与GAT之间没有一致(p < 0.0001,下限:-0.9433,上限:6.8914;95% CI = -1.6097至- 0.02769)。使用荧光素(Mann-Whitney U检验,p = 0.110)和未使用荧光素(Mann-Whitney U检验,p = 0.083)的IOP测量结果在性别上无统计学差异。结论:未使用荧光素的IOP测量值比使用荧光素的IOP测量值低约3mmhg。我们建议从业人员维持荧光素GAT的金标准,以指导青光眼的准确诊断和管理决策。资金:自筹资金。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书