Design and optimization of a multiplex real-time PCR assay for detection of Hepatitis C virus (HCV), Human immunodeficiency virus-1 (HIV-1) and Human hepegivirus-1 (HHpgV-1).

Q3 Medicine
Paria Pirasteh, Seyed Reza Mohebbi, Seyed Masoud Hosseini, Shabnam Kazemian, Amir Ghaemi, Abolfazl Fateh, Mohammad Reza Zali
{"title":"Design and optimization of a multiplex real-time PCR assay for detection of Hepatitis C virus (HCV), Human immunodeficiency virus-1 (HIV-1) and Human hepegivirus-1 (HHpgV-1).","authors":"Paria Pirasteh, Seyed Reza Mohebbi, Seyed Masoud Hosseini, Shabnam Kazemian, Amir Ghaemi, Abolfazl Fateh, Mohammad Reza Zali","doi":"10.22037/ghfbb.v18i3.3197","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The objective of this study was to develop a real-time PCR method to detect hepatitis C virus (HCV), human immunodeficiency virus-1 (HIV-1), and also recently discovered human hepegivirus-1 (HHpgV-1) through melting curve analysis using SYBR Green dye in a single reaction.</p><p><strong>Background: </strong>It is estimated that chronic viral infections affect millions of people worldwide, and a significant number of these individuals are unaware of their infection. In addition, infection with newly discovered and emerging viruses may put public health at potential risks. Precise and early detection is a primary and important task for controlling infections and helping patients.</p><p><strong>Methods: </strong>A set of specific primers were designed for detection of HCV, HIV-1, and HHpgV-1 in a single tube. The real-time polymerase chain reaction was performed and melt curves were analyzed. Specificity was assessed by cross-reaction tests with other common blood-borne pathogens. The established assay was evaluated for the detection of viruses in clinical samples.</p><p><strong>Results: </strong>The three viruses were clearly distinguished by their respective melting temperature values. The detection limits of this assay were 10<sup>2</sup> copies/ml for each virus. The clinical evaluation of this assay was demonstrated by analyzing 134 patients' serum samples. The specificity of the developed assay considered as 100%.</p><p><strong>Conclusion: </strong>The developed multiplex real-time PCR based on SYBR Green dye is a well-suited detection assay of single or co-infections of HCV, HIV, and HHpgV-1 in clinical and research laboratories. It can be used as a cost-effective, rapid tool for routine diagnostic in-house tests.</p>","PeriodicalId":12636,"journal":{"name":"Gastroenterology and Hepatology From Bed to Bench","volume":"18 3","pages":"353-360"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12535783/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gastroenterology and Hepatology From Bed to Bench","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/ghfbb.v18i3.3197","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The objective of this study was to develop a real-time PCR method to detect hepatitis C virus (HCV), human immunodeficiency virus-1 (HIV-1), and also recently discovered human hepegivirus-1 (HHpgV-1) through melting curve analysis using SYBR Green dye in a single reaction.

Background: It is estimated that chronic viral infections affect millions of people worldwide, and a significant number of these individuals are unaware of their infection. In addition, infection with newly discovered and emerging viruses may put public health at potential risks. Precise and early detection is a primary and important task for controlling infections and helping patients.

Methods: A set of specific primers were designed for detection of HCV, HIV-1, and HHpgV-1 in a single tube. The real-time polymerase chain reaction was performed and melt curves were analyzed. Specificity was assessed by cross-reaction tests with other common blood-borne pathogens. The established assay was evaluated for the detection of viruses in clinical samples.

Results: The three viruses were clearly distinguished by their respective melting temperature values. The detection limits of this assay were 102 copies/ml for each virus. The clinical evaluation of this assay was demonstrated by analyzing 134 patients' serum samples. The specificity of the developed assay considered as 100%.

Conclusion: The developed multiplex real-time PCR based on SYBR Green dye is a well-suited detection assay of single or co-infections of HCV, HIV, and HHpgV-1 in clinical and research laboratories. It can be used as a cost-effective, rapid tool for routine diagnostic in-house tests.

Abstract Image

Abstract Image

丙型肝炎病毒(HCV)、人类免疫缺陷病毒-1 (HIV-1)和人类肝炎病毒-1 (HHpgV-1)多重实时PCR检测方法的设计与优化
目的:利用SYBR绿染料,建立一种实时PCR检测丙型肝炎病毒(HCV)、人类免疫缺陷病毒-1 (HIV-1)和新近发现的人类肝炎病毒-1 (HHpgV-1)的方法。背景:据估计,全世界有数百万人受到慢性病毒感染,其中很大一部分人并没有意识到自己受到了感染。此外,感染新发现和新出现的病毒可能使公共卫生面临潜在风险。准确和早期发现是控制感染和帮助患者的首要和重要任务。方法:设计一套HCV、HIV-1和HHpgV-1单管特异性引物。进行实时聚合酶链反应,分析熔体曲线。通过与其他常见血源性病原体的交叉反应试验评估特异性。对所建立的检测方法在临床样品中的病毒检测效果进行了评价。结果:三种病毒可通过各自的熔点值进行明显区分。每种病毒的检测限为102拷贝/ml。通过分析134例患者的血清样本,证明了该方法的临床评价。所开发的检测方法的特异性被认为是100%。结论:建立的基于SYBR绿染料的多重实时荧光定量PCR是一种适合临床和研究实验室检测HCV、HIV和HHpgV-1单一或合并感染的方法。它可以作为一种具有成本效益的快速工具,用于常规诊断内部测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
29
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书