{"title":"Airborne metals and particulate matter measured inside and outside farmworker homes with evaporative coolers and air filtration interventions.","authors":"Kelly Chen, Nikki Catangay, Zhong-Min Wang, Mingyu Wang, Aditya Singh, Mohammad Heidarinejad, Brent Stephens, Isabella Kaser, Ruben Rodriguez, Nayamin Martinez, Gina Solomon, Jeff Wagner","doi":"10.1080/10962247.2025.2572811","DOIUrl":null,"url":null,"abstract":"<p><p>Evaporative (\"swamp\") coolers (ECs) are used for cooling of homes in hot and arid climates. Because ECs draw in large volumes of outdoor air, they can introduce substantial amounts of ambient airborne particulate matter (PM) and other pollutants indoors, which is especially exacerbated during wildfire smoke events. We measured airborne metals and PM inside and outside farmworkers' homes with ECs in the California San Joaquin Valley, U.S.A. Sampling was conducted as part of a larger study (FRESSCA, Filtration for Respiratory Exposure to wildfire Smoke from Swamp Cooler Air) to develop and evaluate an affordable EC filtration solution. All homes received portable air cleaners (PACs), and approximately half the homes received filters on their EC air intakes. Indoor and outdoor airborne metals were actively measured using 24-hr air sampling. Airborne metals were dominated by Fe, with some detections of Cu, Mn, Zn, and Se. Indoor/outdoor (I/O) ratios for Fe were mostly <1 and were lower for homes with EC filters. Metals analyses of the EC filters themselves revealed additional metals, likely due to the longer sampling time. These metals were partially removed from the air entering participants' homes by EC filters. Passive PM samplers were deployed for 70 days and analyzed using electron microscopy. PM samples revealed crustal, carbonaceous, and agriculture-related particle types, including Cu-rich fungicides. PM levels were lower indoors compared to outdoors in all homes (30%-70%). Some evidence of greater PM reductions in homes with EC filters was observed, with 25% reductions in coarse PM<sub>10-2.5</sub> in homes with EC filters that used their ECs more frequently (<i>p</i> < 0.05). Few smoke events during the study limited our ability to detect differences in PM from wildfires. However, the measured reductions in coarse PM are important for communities heavily impacted by dust, both for home cleanliness and for protection from upper-airway health impacts.<i>Implications</i>: Do-it-yourself evaporative cooler filters are a promising and affordable method of reducing dust infiltration in homes burdened by heat stress and poor outdoor air quality. Further evaluation during wildfire smoke events and optimization of evaporative cooler filter interventions could eventually reduce respiratory-related health impacts in communities affected by a changing climate.</p>","PeriodicalId":520693,"journal":{"name":"Journal of the Air & Waste Management Association (1995)","volume":" ","pages":"91-107"},"PeriodicalIF":2.2000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air & Waste Management Association (1995)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10962247.2025.2572811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Evaporative ("swamp") coolers (ECs) are used for cooling of homes in hot and arid climates. Because ECs draw in large volumes of outdoor air, they can introduce substantial amounts of ambient airborne particulate matter (PM) and other pollutants indoors, which is especially exacerbated during wildfire smoke events. We measured airborne metals and PM inside and outside farmworkers' homes with ECs in the California San Joaquin Valley, U.S.A. Sampling was conducted as part of a larger study (FRESSCA, Filtration for Respiratory Exposure to wildfire Smoke from Swamp Cooler Air) to develop and evaluate an affordable EC filtration solution. All homes received portable air cleaners (PACs), and approximately half the homes received filters on their EC air intakes. Indoor and outdoor airborne metals were actively measured using 24-hr air sampling. Airborne metals were dominated by Fe, with some detections of Cu, Mn, Zn, and Se. Indoor/outdoor (I/O) ratios for Fe were mostly <1 and were lower for homes with EC filters. Metals analyses of the EC filters themselves revealed additional metals, likely due to the longer sampling time. These metals were partially removed from the air entering participants' homes by EC filters. Passive PM samplers were deployed for 70 days and analyzed using electron microscopy. PM samples revealed crustal, carbonaceous, and agriculture-related particle types, including Cu-rich fungicides. PM levels were lower indoors compared to outdoors in all homes (30%-70%). Some evidence of greater PM reductions in homes with EC filters was observed, with 25% reductions in coarse PM10-2.5 in homes with EC filters that used their ECs more frequently (p < 0.05). Few smoke events during the study limited our ability to detect differences in PM from wildfires. However, the measured reductions in coarse PM are important for communities heavily impacted by dust, both for home cleanliness and for protection from upper-airway health impacts.Implications: Do-it-yourself evaporative cooler filters are a promising and affordable method of reducing dust infiltration in homes burdened by heat stress and poor outdoor air quality. Further evaluation during wildfire smoke events and optimization of evaporative cooler filter interventions could eventually reduce respiratory-related health impacts in communities affected by a changing climate.

用蒸发冷却器和空气过滤干预措施测量农场工人家庭内外的空气中金属和颗粒物。
蒸发式(“沼泽”)冷却器(ECs)用于炎热和干旱气候下的家庭制冷。由于ec吸入大量室外空气,它们可以将大量的环境空气颗粒物(PM)和其他污染物引入室内,这在野火烟雾事件中尤其加剧。我们用ECs测量了美国加州圣华金河谷农场工人家内外空气中的金属和PM。采样作为更大的研究(FRESSCA,呼吸暴露于沼泽冷却器空气中野火烟雾的过滤)的一部分进行,以开发和评估经济实惠的EC过滤解决方案。所有家庭都安装了便携式空气净化器(PACs),大约一半的家庭在EC进气口安装了过滤器。采用24小时空气采样主动测量室内和室外空气中的金属含量。空气中金属以铁为主,少量检出铜、锰。Zn和Se。在使用EC过滤器的家庭中,室内/室外(I/O)铁的比率大多为10-2.5,而EC过滤器的使用频率更高(p含义:在受热压力和室外空气质量差影响的家庭中,自己动手的蒸发冷却器过滤器是一种有前途且负担得起的减少灰尘渗透的方法。野火烟雾事件期间的进一步评估和蒸发冷却器过滤器干预措施的优化最终可以减少受气候变化影响的社区中与呼吸相关的健康影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书