Investigation on the efficacy of a tissue equivalent material bolus for BNCT

IF 2.2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Akinori Sasaki, Naonori Hu, Ryo Kakino, Mai Nojiri, Keiji Nihei, Teruhito Aihara, Satoshi Takeno, Yuki Yoshino, Hiroki Tanaka, Koji Ono
{"title":"Investigation on the efficacy of a tissue equivalent material bolus for BNCT","authors":"Akinori Sasaki,&nbsp;Naonori Hu,&nbsp;Ryo Kakino,&nbsp;Mai Nojiri,&nbsp;Keiji Nihei,&nbsp;Teruhito Aihara,&nbsp;Satoshi Takeno,&nbsp;Yuki Yoshino,&nbsp;Hiroki Tanaka,&nbsp;Koji Ono","doi":"10.1002/acm2.70287","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>In radiation therapy, the use of bolus is an effective technique for improving the surface dose. This irradiation technique is also used in BNCT. However, since BNCT uses neutron irradiation, it is important to evaluate both the neutron moderation characteristic and the radioactivation of the bolus.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>This study aimed to evaluate the tissue equivalence and activation of commercially available boluses for use in BNCT.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Two types of commercially available boluses were evaluated. The boluses were placed on a water phantom and irradiated using the NeuCure BNCT system. Firstly, the tissue equivalency of the boluses was evaluated by comparing the experimentally measured thermal neutron flux and gamma-ray distribution within the phantom, and the results were compared with simulation results. Secondly, the neutron activation of the boluses was assessed using an ionization chamber survey meter and an HP-Ge semiconductor detector to identify the produced radionuclides.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The thermal neutron flux and gamma ray distribution in the water phantom agreed well between the measured and simulated results. The study revealed that both boluses became radioactive after neutron irradiation, primarily due to the production of radionuclides such as <sup>24</sup>Na and <sup>38</sup>Cl.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>While boluses are effective in improving surface dose in BNCT, their use also introduces the risk of patient exposure to radiation from radioactivated bolus materials. Therefore, careful selection of bolus materials with minimal radioactivation is crucial to ensure patient safety.</p>\n </section>\n </div>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":"26 10","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2025-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://aapm.onlinelibrary.wiley.com/doi/epdf/10.1002/acm2.70287","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://aapm.onlinelibrary.wiley.com/doi/10.1002/acm2.70287","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

In radiation therapy, the use of bolus is an effective technique for improving the surface dose. This irradiation technique is also used in BNCT. However, since BNCT uses neutron irradiation, it is important to evaluate both the neutron moderation characteristic and the radioactivation of the bolus.

Purpose

This study aimed to evaluate the tissue equivalence and activation of commercially available boluses for use in BNCT.

Methods

Two types of commercially available boluses were evaluated. The boluses were placed on a water phantom and irradiated using the NeuCure BNCT system. Firstly, the tissue equivalency of the boluses was evaluated by comparing the experimentally measured thermal neutron flux and gamma-ray distribution within the phantom, and the results were compared with simulation results. Secondly, the neutron activation of the boluses was assessed using an ionization chamber survey meter and an HP-Ge semiconductor detector to identify the produced radionuclides.

Results

The thermal neutron flux and gamma ray distribution in the water phantom agreed well between the measured and simulated results. The study revealed that both boluses became radioactive after neutron irradiation, primarily due to the production of radionuclides such as 24Na and 38Cl.

Conclusions

While boluses are effective in improving surface dose in BNCT, their use also introduces the risk of patient exposure to radiation from radioactivated bolus materials. Therefore, careful selection of bolus materials with minimal radioactivation is crucial to ensure patient safety.

Abstract Image

组织等效材料丸治疗BNCT疗效的研究
背景在放射治疗中,使用微丸是提高表面剂量的一种有效技术。这种照射技术也用于BNCT。然而,由于BNCT使用中子辐照,因此评估中子缓和特性和丸的放射性是很重要的。目的本研究旨在评估市售脑丸用于BNCT的组织等效性和活化性。方法对两种市售大药丸进行评价。这些小丸被放置在水模上,并使用neuure BNCT系统进行照射。首先,通过对比实验测量的热中子通量和射线分布,评价了丸剂的组织等效性,并与模拟结果进行了比较。其次,利用电离室测量仪和HP-Ge半导体探测器对丸的中子活化进行了评估,以确定产生的放射性核素。结果水模体的热中子通量和伽马射线分布与模拟结果吻合较好。研究表明,这两种丸剂在中子辐照后都具有放射性,主要是由于产生了放射性核素,如24Na和38Cl。结论:虽然丸剂可以有效提高BNCT的表面剂量,但它们的使用也会增加患者暴露于放射性丸剂材料辐射的风险。因此,谨慎选择具有最小放射性的丸剂材料对于确保患者安全至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
19.00%
发文量
331
审稿时长
3 months
期刊介绍: Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission. JACMP will publish: -Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500. -Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed. -Technical Notes: These should be no longer than 3000 words, including key references. -Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents. -Book Reviews: The editorial office solicits Book Reviews. -Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics. -Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信