Energy Output Variability Among Phacoemulsification Tips Using Calorimetry.

IF 1.5 Q4 ENGINEERING, BIOMEDICAL
Medical Devices-Evidence and Research Pub Date : 2025-10-03 eCollection Date: 2025-01-01 DOI:10.2147/MDER.S538849
Ivan A Cardenas, Reiker G Ricks, Jenna L Jensen, Tanner K Nelson, William R Barlow Jnr, Randall J Olson, Jeff H Pettey
{"title":"Energy Output Variability Among Phacoemulsification Tips Using Calorimetry.","authors":"Ivan A Cardenas, Reiker G Ricks, Jenna L Jensen, Tanner K Nelson, William R Barlow Jnr, Randall J Olson, Jeff H Pettey","doi":"10.2147/MDER.S538849","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine if using different phacoemulsification (phaco) tips will impact thermal energy output utilizing calorimetry.</p><p><strong>Methods: </strong>The Alcon Centurion was used with the Infiniti OZil handpiece and balanced, hybrid, or MST Dewey A1 mini tip. Settings were 100% power, continuous torsional or longitudinal ultrasound, 0mmHg vacuum limit, and flow rate 12mL/min. Outflow tubing was removed from the handpiece and inflow tubing was manually occluded. The handpiece tip was placed into the calorimeter filled with 50mL of degassed deionized water and ultrasound was initiated for 1 minute. Temperature rise and cumulative dissipated energy (CDE) were recorded; ten trials were performed for each group.</p><p><strong>Results: </strong>Statistically significant differences in energy output, measured in Joules, were found between all three tips in both ultrasound modes. Balanced tips showed the highest output, Dewey tips had the lowest. Hybrid tips had significantly increased output in longitudinal mode, whereas Dewey tips had significantly decreased output in longitudinal mode. No significant differences were seen in CDE between tips in either ultrasound mode, but significant increases were seen in longitudinal mode within each tip.</p><p><strong>Conclusion: </strong>This study demonstrated differences in thermal energy production of three different phaco handpiece tips. This provides insight into how thermal injuries occur and what might cause these differences. Our methodology provides a novel way for accurate energy measurement at the tip, though it differs when compared to external energy production measurements. Surgeons should take into consideration the significant variability in thermal energy created by handpiece tips.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":"18 ","pages":"485-493"},"PeriodicalIF":1.5000,"publicationDate":"2025-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12502956/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S538849","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To determine if using different phacoemulsification (phaco) tips will impact thermal energy output utilizing calorimetry.

Methods: The Alcon Centurion was used with the Infiniti OZil handpiece and balanced, hybrid, or MST Dewey A1 mini tip. Settings were 100% power, continuous torsional or longitudinal ultrasound, 0mmHg vacuum limit, and flow rate 12mL/min. Outflow tubing was removed from the handpiece and inflow tubing was manually occluded. The handpiece tip was placed into the calorimeter filled with 50mL of degassed deionized water and ultrasound was initiated for 1 minute. Temperature rise and cumulative dissipated energy (CDE) were recorded; ten trials were performed for each group.

Results: Statistically significant differences in energy output, measured in Joules, were found between all three tips in both ultrasound modes. Balanced tips showed the highest output, Dewey tips had the lowest. Hybrid tips had significantly increased output in longitudinal mode, whereas Dewey tips had significantly decreased output in longitudinal mode. No significant differences were seen in CDE between tips in either ultrasound mode, but significant increases were seen in longitudinal mode within each tip.

Conclusion: This study demonstrated differences in thermal energy production of three different phaco handpiece tips. This provides insight into how thermal injuries occur and what might cause these differences. Our methodology provides a novel way for accurate energy measurement at the tip, though it differs when compared to external energy production measurements. Surgeons should take into consideration the significant variability in thermal energy created by handpiece tips.

Abstract Image

Abstract Image

Abstract Image

用量热法测定超声乳化尖端的能量输出变异性。
目的:利用量热法确定使用不同的超声乳化(phaco)尖端是否会影响热能输出。方法:使用爱尔康百夫长Infiniti OZil手机和平衡,混合,或MST杜威A1迷你尖端。设置为100%功率,连续扭转或纵向超声,0mmHg真空限制,流量12mL/min。从机头上取下流出管,手动堵塞流入管。将手机尖端放入盛有50mL脱气去离子水的量热计中,启动超声1分钟。记录温升和累积耗散能(CDE);每组进行10次试验。结果:在两种超声模式下,以焦耳为单位测量的能量输出在统计上有显著差异。平衡叶片的产量最高,杜威叶片的产量最低。杂交叶尖在纵向模式下显著增加了产量,而杜威叶尖在纵向模式下显著降低了产量。在两种超声模式下,CDE在尖端之间没有显著差异,但在每个尖端的纵向模式下,CDE显著增加。结论:本研究证明了三种不同的phaco手机尖端的热能产生差异。这为热损伤是如何发生以及可能导致这些差异的原因提供了见解。我们的方法为尖端精确的能量测量提供了一种新颖的方法,尽管与外部能量生产测量相比有所不同。外科医生应考虑到手机尖端产生的热能的显著变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书