Dongxia He , Hu Liang , Yishu Deng , Yingying Huang , Yixuan Wang , Nian Lu , Yuanji Xu , Zhizhong Lin , Zijie Wu , Yujun Hu , Chixiong Liang , Shuyu Wen , Youping Xiao , Chuanmiao Xie , Liangru Ke
{"title":"Modifying node-RADS in diagnosing parotid lymph node metastasis of nasopharyngeal carcinoma","authors":"Dongxia He , Hu Liang , Yishu Deng , Yingying Huang , Yixuan Wang , Nian Lu , Yuanji Xu , Zhizhong Lin , Zijie Wu , Yujun Hu , Chixiong Liang , Shuyu Wen , Youping Xiao , Chuanmiao Xie , Liangru Ke","doi":"10.1016/j.ejrad.2025.112451","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>This study aimed to establish a modified Node Reporting and Data System (mNode-RADS) for differentiating metastatic from benign parotid lymph nodes (PLNs) in nasopharyngeal carcinoma (NPC).</div></div><div><h3>Materials and methods</h3><div>166 and 60 NPC patients with PLN from two institutions were retrospectively reviewed. The diagnostic performance of initial imaging characteristics for metastatic PLN (PLNM) was compared using the area under the curve (AUC). Two top-performing variables, lesion area and short axis, were used to modify Node-RADS (la-mNode-RADS and sa-mNoder-RADS, respectively). The AUC, sensitivity, specificity, and accuracy were compared among short axis, conventional and modified Node-RADS criteria.</div></div><div><h3>Results</h3><div>In the internal cohort, the lesion area showed the highest diagnostic performance (AUC = 0.877; cutoff = 60.69 mm<sup>2</sup>), followed by the short axis (AUC = 0.869; cutoff = 7.5 mm). Both la-mNode-RADS and sa-mNode-RADS achieved higher AUCs than Node-RADS (0.912 or 0.911 vs. 0.870; all <em>p</em> < 0.05). Dichotomized la-mNode-RADS and sa-mNode-RADS (scores 1–2 vs. 3–5) showed greater sensitivity than Node-RADS or short axis (94.8 % vs. 92.7 % vs. 76.0 % vs. 77.1 %; all <em>p</em> < 0.05), with similar specificity (78.7 % vs. 79.8 % vs. 84.3 % vs. 86.5 %; all <em>p</em> > 0.05). Both la-mNode-RADS and sa-mNode-RADS had higher accuracy than Node-RADS (87.0 % or 86.5 % vs. 80.0 %; all <em>p</em> < 0.05). No significant differences were observed between la-mNode-RADS and sa-mNode-RADS. The superior diagnostic performance of short-axis threshold of 7.5 mm and its corresponding mNode-RADS was also confirmed in external cohort.</div></div><div><h3>Conclusions</h3><div>The user-friendly sa-mNode-RADS shows superior diagnostic performance over traditional Node-RADS in detecting PLNM in NPC.</div></div>","PeriodicalId":12063,"journal":{"name":"European Journal of Radiology","volume":"193 ","pages":"Article 112451"},"PeriodicalIF":3.3000,"publicationDate":"2025-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0720048X25005376","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
This study aimed to establish a modified Node Reporting and Data System (mNode-RADS) for differentiating metastatic from benign parotid lymph nodes (PLNs) in nasopharyngeal carcinoma (NPC).
Materials and methods
166 and 60 NPC patients with PLN from two institutions were retrospectively reviewed. The diagnostic performance of initial imaging characteristics for metastatic PLN (PLNM) was compared using the area under the curve (AUC). Two top-performing variables, lesion area and short axis, were used to modify Node-RADS (la-mNode-RADS and sa-mNoder-RADS, respectively). The AUC, sensitivity, specificity, and accuracy were compared among short axis, conventional and modified Node-RADS criteria.
Results
In the internal cohort, the lesion area showed the highest diagnostic performance (AUC = 0.877; cutoff = 60.69 mm2), followed by the short axis (AUC = 0.869; cutoff = 7.5 mm). Both la-mNode-RADS and sa-mNode-RADS achieved higher AUCs than Node-RADS (0.912 or 0.911 vs. 0.870; all p < 0.05). Dichotomized la-mNode-RADS and sa-mNode-RADS (scores 1–2 vs. 3–5) showed greater sensitivity than Node-RADS or short axis (94.8 % vs. 92.7 % vs. 76.0 % vs. 77.1 %; all p < 0.05), with similar specificity (78.7 % vs. 79.8 % vs. 84.3 % vs. 86.5 %; all p > 0.05). Both la-mNode-RADS and sa-mNode-RADS had higher accuracy than Node-RADS (87.0 % or 86.5 % vs. 80.0 %; all p < 0.05). No significant differences were observed between la-mNode-RADS and sa-mNode-RADS. The superior diagnostic performance of short-axis threshold of 7.5 mm and its corresponding mNode-RADS was also confirmed in external cohort.
Conclusions
The user-friendly sa-mNode-RADS shows superior diagnostic performance over traditional Node-RADS in detecting PLNM in NPC.
期刊介绍:
European Journal of Radiology is an international journal which aims to communicate to its readers, state-of-the-art information on imaging developments in the form of high quality original research articles and timely reviews on current developments in the field.
Its audience includes clinicians at all levels of training including radiology trainees, newly qualified imaging specialists and the experienced radiologist. Its aim is to inform efficient, appropriate and evidence-based imaging practice to the benefit of patients worldwide.