Transforaminal "in-out-in" screw technique for posterior C2 fixation in cases with a narrow C2 pedicle: anatomical considerations, technical notes, and preliminary clinical results.

IF 2.7 Q2 ORTHOPEDICS
Jun Yan, Cheng Qiu, Lei Qi, Lei Cheng, Yan-Ping Zheng, Xin-Yu Liu
{"title":"Transforaminal \"in-out-in\" screw technique for posterior C2 fixation in cases with a narrow C2 pedicle: anatomical considerations, technical notes, and preliminary clinical results.","authors":"Jun Yan, Cheng Qiu, Lei Qi, Lei Cheng, Yan-Ping Zheng, Xin-Yu Liu","doi":"10.31616/asj.2025.0160","DOIUrl":null,"url":null,"abstract":"<p><p>Numerous techniques for C2 screw fixation have been recently reported. However, concerns remain regarding the risk of spinal cord or vertebral artery injury and inadequate biomechanical stability. To our knowledge, the specific transforaminal \"in-out-in\" screw fixation technique has not been previously reported. This study aimed to investigate the feasibility and preliminary clinical outcomes of a transforaminal \"in-out-in\" multi-cortical purchase screw for posterior C2 screw fixation. Between October 2022 and March 2023, 10 patients underwent posterior atlantoaxial internal fixation. All patients had severe hypoplasia of the C2 pedicle on at least one side, precluding the use of standard C2 pedicle screws. A transforaminal \"in-out-in\" screw was used as an alternative. No spinal cord injury, vascular injury, or other major complications were observed. No implant failure was noted at the final follow-up. In conclusion, the transforaminal \"in-out-in\" screw may achieve rigid three-column fixation with multiple cortical purchases. It represents a safe and effective alternative for posterior C2 fixation in patients with severely narrow C2 pedicles where traditional pedicle screw placement is not feasible.</p>","PeriodicalId":8555,"journal":{"name":"Asian Spine Journal","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Spine Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31616/asj.2025.0160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Numerous techniques for C2 screw fixation have been recently reported. However, concerns remain regarding the risk of spinal cord or vertebral artery injury and inadequate biomechanical stability. To our knowledge, the specific transforaminal "in-out-in" screw fixation technique has not been previously reported. This study aimed to investigate the feasibility and preliminary clinical outcomes of a transforaminal "in-out-in" multi-cortical purchase screw for posterior C2 screw fixation. Between October 2022 and March 2023, 10 patients underwent posterior atlantoaxial internal fixation. All patients had severe hypoplasia of the C2 pedicle on at least one side, precluding the use of standard C2 pedicle screws. A transforaminal "in-out-in" screw was used as an alternative. No spinal cord injury, vascular injury, or other major complications were observed. No implant failure was noted at the final follow-up. In conclusion, the transforaminal "in-out-in" screw may achieve rigid three-column fixation with multiple cortical purchases. It represents a safe and effective alternative for posterior C2 fixation in patients with severely narrow C2 pedicles where traditional pedicle screw placement is not feasible.

经椎间孔“内-外-内”螺钉技术在狭窄C2椎弓根病例中的后路固定:解剖学考虑、技术注意事项和初步临床结果。
最近报道了许多C2螺钉固定技术。然而,对脊髓或椎动脉损伤风险和生物力学稳定性不足的担忧仍然存在。据我们所知,具体的经椎间孔“内-外-内”螺钉固定技术以前未见报道。本研究旨在探讨经椎间孔“内-外-内”多皮质购买螺钉用于后路C2螺钉固定的可行性和初步临床结果。在2022年10月至2023年3月期间,10例患者接受了寰枢后路内固定。所有患者至少有一侧C2椎弓根严重发育不全,因此无法使用标准的C2椎弓根螺钉。采用椎间孔内-外-内螺钉作为替代。无脊髓损伤、血管损伤及其他主要并发症。在最后的随访中没有发现种植体失败。总之,经椎间孔“内-外-内”螺钉可实现多皮质购买的刚性三柱固定。对于C2椎弓根严重狭窄而传统椎弓根螺钉置入不可行的患者,它是一种安全有效的后路C2固定方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Asian Spine Journal
Asian Spine Journal ORTHOPEDICS-
CiteScore
5.10
自引率
4.30%
发文量
108
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信