Decreasing opioid provision and use while maintaining analgesia efficacy in cervical preparation with osmotic dilators before dilation and evacuation: A quality improvement initiative
{"title":"Decreasing opioid provision and use while maintaining analgesia efficacy in cervical preparation with osmotic dilators before dilation and evacuation: A quality improvement initiative","authors":"Paige D. Kendall , Jeanelle Sheeder , Nancy Fang","doi":"10.1016/j.contraception.2025.111236","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>To reduce opioid use and provision while maintaining analgesia and patient satisfaction with osmotic dilators for cervical preparation before dilation and evacuation (D&E).</div></div><div><h3>Study design</h3><div>We conducted a quality improvement initiative to reduce opioid use by studying an analgesia protocol change from the existing “routine opioid provision” to a novel “opioid-sparing” protocol. We collected data through patient surveys from patients undergoing overnight osmotic dilators before D&E from 16 to 26 weeks of gestation. We assessed pain on a numeric rating scale (0–10) before dilator placement (baseline) and D&E. The primary outcome was median change in individual pain score from baseline to maximum overnight with osmotic dilators in place.</div></div><div><h3>Results</h3><div>Opioid provision (93.9% vs 10.3%, <em>p</em> < 0.001) and opioid use (57.6% vs 7.7%, <em>p</em> < 0.001) were lower in the novel opioid-sparing group. Median change in individual pain score was lower in the novel opioid-sparing group (7.0 [0–10]) compared to the existing routine opioid group (8.0 [0–10]) (<em>p</em> = 0.01).</div></div><div><h3>Conclusions</h3><div>The novel opioid-sparing protocol reduced opioid provision and use while also demonstrating lower pain scores and maintaining satisfaction in patients undergoing osmotic dilators before D&E.</div></div><div><h3>Implications</h3><div>Limiting opioid use for cervical preparation with osmotic dilators before second-trimester dilation and evacuation can reduce opioid provision and use, while maintaining analgesia efficacy and patient satisfaction.</div></div>","PeriodicalId":10762,"journal":{"name":"Contraception","volume":"153 ","pages":"Article 111236"},"PeriodicalIF":2.5000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contraception","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0010782425004275","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To reduce opioid use and provision while maintaining analgesia and patient satisfaction with osmotic dilators for cervical preparation before dilation and evacuation (D&E).
Study design
We conducted a quality improvement initiative to reduce opioid use by studying an analgesia protocol change from the existing “routine opioid provision” to a novel “opioid-sparing” protocol. We collected data through patient surveys from patients undergoing overnight osmotic dilators before D&E from 16 to 26 weeks of gestation. We assessed pain on a numeric rating scale (0–10) before dilator placement (baseline) and D&E. The primary outcome was median change in individual pain score from baseline to maximum overnight with osmotic dilators in place.
Results
Opioid provision (93.9% vs 10.3%, p < 0.001) and opioid use (57.6% vs 7.7%, p < 0.001) were lower in the novel opioid-sparing group. Median change in individual pain score was lower in the novel opioid-sparing group (7.0 [0–10]) compared to the existing routine opioid group (8.0 [0–10]) (p = 0.01).
Conclusions
The novel opioid-sparing protocol reduced opioid provision and use while also demonstrating lower pain scores and maintaining satisfaction in patients undergoing osmotic dilators before D&E.
Implications
Limiting opioid use for cervical preparation with osmotic dilators before second-trimester dilation and evacuation can reduce opioid provision and use, while maintaining analgesia efficacy and patient satisfaction.
期刊介绍:
Contraception has an open access mirror journal Contraception: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review.
The journal Contraception wishes to advance reproductive health through the rapid publication of the best and most interesting new scholarship regarding contraception and related fields such as abortion. The journal welcomes manuscripts from investigators working in the laboratory, clinical and social sciences, as well as public health and health professions education.