Ultra-fast whole-brain T2-weighted imaging in 7 seconds using dual-type deep learning reconstruction with single-shot acquisition: clinical feasibility and comparison with conventional methods.

IF 2.1 4区 医学
Yohei Ikebe, Noriyuki Fujima, Hiroyuki Kameda, Taisuke Harada, Yukie Shimizu, Jihun Kwon, Masami Yoneyama, Kohsuke Kudo
{"title":"Ultra-fast whole-brain T2-weighted imaging in 7 seconds using dual-type deep learning reconstruction with single-shot acquisition: clinical feasibility and comparison with conventional methods.","authors":"Yohei Ikebe, Noriyuki Fujima, Hiroyuki Kameda, Taisuke Harada, Yukie Shimizu, Jihun Kwon, Masami Yoneyama, Kohsuke Kudo","doi":"10.1007/s11604-025-01875-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the image quality and clinical utility of ultra-fast T2-weighted imaging (UF-T2WI), which acquires all slice data in 7 s using a single-shot turbo spin-echo technique combined with dual-type deep learning (DL) reconstruction, incorporating DL-based image denoising and super-resolution processing, by comparing UF-T2WI with conventional T2WI.</p><p><strong>Material and methods: </strong>We analyzed data from 38 patients who underwent both conventional T2WI and UF-T2WI with the dual-type DL-based image reconstruction. Two board-certified radiologists independently performed blinded qualitative assessments of the patients' images obtained with UF-T2WI with DL and conventional T2WI, evaluating the overall image quality, anatomical structure visibility, and levels of noise and artifacts. In cases that included central nervous system diseases, the lesions' delineation was also assessed. The quantitative analysis included measurements of signal-to-noise ratios in white and gray matter and the contrast-to-noise ratio between gray and white matter.</p><p><strong>Results: </strong>Compared to conventional T2WI, UF-T2WI with DL received significantly higher ratings for overall image quality and lower noise and artifact levels (p < 0.001 for both readers). The anatomical visibility was significantly better in UF-T2WI for one reader, with no significant difference for the other reader. The lesion visibility in UF-T2WI was comparable to that in conventional T2WI. Quantitatively, the SNRs and CNRs were all significantly higher in UF-T2WI than conventional T2WI (p < 0.001).</p><p><strong>Conclusion: </strong>The combination of SSTSE with dual-type DL reconstruction allows for the acquisition of clinically acceptable T2WI images in just 7 s. This technique shows strong potential to reduce MRI scan times and improve clinical workflow efficiency.</p>","PeriodicalId":14691,"journal":{"name":"Japanese Journal of Radiology","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11604-025-01875-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the image quality and clinical utility of ultra-fast T2-weighted imaging (UF-T2WI), which acquires all slice data in 7 s using a single-shot turbo spin-echo technique combined with dual-type deep learning (DL) reconstruction, incorporating DL-based image denoising and super-resolution processing, by comparing UF-T2WI with conventional T2WI.

Material and methods: We analyzed data from 38 patients who underwent both conventional T2WI and UF-T2WI with the dual-type DL-based image reconstruction. Two board-certified radiologists independently performed blinded qualitative assessments of the patients' images obtained with UF-T2WI with DL and conventional T2WI, evaluating the overall image quality, anatomical structure visibility, and levels of noise and artifacts. In cases that included central nervous system diseases, the lesions' delineation was also assessed. The quantitative analysis included measurements of signal-to-noise ratios in white and gray matter and the contrast-to-noise ratio between gray and white matter.

Results: Compared to conventional T2WI, UF-T2WI with DL received significantly higher ratings for overall image quality and lower noise and artifact levels (p < 0.001 for both readers). The anatomical visibility was significantly better in UF-T2WI for one reader, with no significant difference for the other reader. The lesion visibility in UF-T2WI was comparable to that in conventional T2WI. Quantitatively, the SNRs and CNRs were all significantly higher in UF-T2WI than conventional T2WI (p < 0.001).

Conclusion: The combination of SSTSE with dual-type DL reconstruction allows for the acquisition of clinically acceptable T2WI images in just 7 s. This technique shows strong potential to reduce MRI scan times and improve clinical workflow efficiency.

双型深度学习重建单次采集7秒超快速全脑t2加权成像:临床可行性及与常规方法的比较
目的:通过对比超快速t2加权成像(UF-T2WI)和常规T2WI,评估其图像质量和临床应用价值。超快速t2加权成像(UF-T2WI)采用单次涡轮自旋回波技术,结合基于深度学习的图像去噪和超分辨率处理,在7秒内获得所有切片数据。材料和方法:我们分析了38例常规T2WI和UF-T2WI患者的数据,并基于双型dl图像重建。两名委员会认证的放射科医生独立地对患者通过DL和常规T2WI获得的UF-T2WI图像进行盲法定性评估,评估整体图像质量、解剖结构可见性、噪声和伪影水平。在包括中枢神经系统疾病的病例中,也评估了病变的划定。定量分析包括测量白质和灰质的信噪比以及灰质和白质之间的对比噪声比。结果:与传统T2WI相比,UF-T2WI合并DL的整体图像质量评分明显更高,噪声和伪影水平也更低(p结论:SSTSE与双型DL重建的结合可以在7秒内获得临床可接受的T2WI图像。该技术在减少MRI扫描时间和提高临床工作流程效率方面显示出强大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Japanese Journal of Radiology
Japanese Journal of Radiology Medicine-Radiology, Nuclear Medicine and Imaging
自引率
4.80%
发文量
133
期刊介绍: Japanese Journal of Radiology is a peer-reviewed journal, officially published by the Japan Radiological Society. The main purpose of the journal is to provide a forum for the publication of papers documenting recent advances and new developments in the field of radiology in medicine and biology. The scope of Japanese Journal of Radiology encompasses but is not restricted to diagnostic radiology, interventional radiology, radiation oncology, nuclear medicine, radiation physics, and radiation biology. Additionally, the journal covers technical and industrial innovations. The journal welcomes original articles, technical notes, review articles, pictorial essays and letters to the editor. The journal also provides announcements from the boards and the committees of the society. Membership in the Japan Radiological Society is not a prerequisite for submission. Contributions are welcomed from all parts of the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信