Three Cases of Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair Effectively Treating Chronic Type B Aortic Dissection with False Lumen Aneurysm.
{"title":"Three Cases of Stent-Assisted Balloon-Induced Intimal Disruption and Relamination in Aortic Dissection Repair Effectively Treating Chronic Type B Aortic Dissection with False Lumen Aneurysm.","authors":"Kanako Kobayashi, Naoki Fujimura, Ayaka Yu, Kyosuke Hosokawa, Yujiro Kawai, Takahito Itoh, Takahiro Shoji, Hirohisa Harada","doi":"10.3400/avd.cr.25-00046","DOIUrl":null,"url":null,"abstract":"<p><p>Successful thoracic endovascular aortic repair for chronic type B aortic dissection with an enlarged false lumen depends on complete exclusion of the false lumen. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) creates a single lumen in the dissected thoracic and abdominal aorta by disrupting the intima. We report our experience in the treatment of 3 cases of chronic dissection using the STABILISE procedure at our hospital from December 2019 to May 2022. The STABILISE technique appears to be an effective procedure; however, further evaluation of risk factors for complications such as intraoperative aortic rupture is necessary.</p>","PeriodicalId":7995,"journal":{"name":"Annals of vascular diseases","volume":"18 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12460030/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of vascular diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3400/avd.cr.25-00046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/20 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Successful thoracic endovascular aortic repair for chronic type B aortic dissection with an enlarged false lumen depends on complete exclusion of the false lumen. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) creates a single lumen in the dissected thoracic and abdominal aorta by disrupting the intima. We report our experience in the treatment of 3 cases of chronic dissection using the STABILISE procedure at our hospital from December 2019 to May 2022. The STABILISE technique appears to be an effective procedure; however, further evaluation of risk factors for complications such as intraoperative aortic rupture is necessary.