Reliability of Different Protocols for Elbow Flexion and Extension Strength Measurement via Hand-held Dynamometer.

IF 0.4
Sevgi Sevi Yeşilyaprak, Fatma Özden, Damla Karabay, Gonca Şahiner Pıçak
{"title":"Reliability of Different Protocols for Elbow Flexion and Extension Strength Measurement via Hand-held Dynamometer.","authors":"Sevgi Sevi Yeşilyaprak, Fatma Özden, Damla Karabay, Gonca Şahiner Pıçak","doi":"10.1055/a-2657-6783","DOIUrl":null,"url":null,"abstract":"<p><p>To investigate the reliability of elbow flexion and extension strength measurements via a hand-held dynamometer (HHD) in different positions and to determine the minimal detectable change (MDC).Reliability study.Twenty healthy university students were evaluated at an exercise laboratory. Elbow flexion and extension strength were each measured by two physiotherapists in three different positions. Intra-class correlation coefficients (ICCs) were calculated to assess intra-rater reliability (ICC 3,3) and inter-rater reliability (ICC 3,3) and were used to calculate MDC.All measurement procedures have excellent intra- and inter-rater reliability scores in females (0.88-0.98) and males (0.81-0.95), except for moderate intra-rater reliability (0.72) for seated measurement of elbow flexion strength with the shoulder at 90-degree flexion in males. There is a systematic difference in inter-rater results for all flexion positions and intra-rater results for one flexion position in males (p<0.05). MDC95% ranged from 3.44 to 11.69 for intra-rater scores and from 6.19 to10.79 for inter-rater scores.All procedures showed excellent reliability, except for moderate intra-rater reliability in seated measurement of elbow flexion strength with the shoulder at 90-degree flexion in males. However, elbow flexion measurement was prone to systematic differences in males. Muscle strength of the tested individual and testers should be considered.</p>","PeriodicalId":520779,"journal":{"name":"Sportverletzung Sportschaden : Organ der Gesellschaft fur Orthopadisch-Traumatologische Sportmedizin","volume":" ","pages":"173-183"},"PeriodicalIF":0.4000,"publicationDate":"2025-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sportverletzung Sportschaden : Organ der Gesellschaft fur Orthopadisch-Traumatologische Sportmedizin","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2657-6783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To investigate the reliability of elbow flexion and extension strength measurements via a hand-held dynamometer (HHD) in different positions and to determine the minimal detectable change (MDC).Reliability study.Twenty healthy university students were evaluated at an exercise laboratory. Elbow flexion and extension strength were each measured by two physiotherapists in three different positions. Intra-class correlation coefficients (ICCs) were calculated to assess intra-rater reliability (ICC 3,3) and inter-rater reliability (ICC 3,3) and were used to calculate MDC.All measurement procedures have excellent intra- and inter-rater reliability scores in females (0.88-0.98) and males (0.81-0.95), except for moderate intra-rater reliability (0.72) for seated measurement of elbow flexion strength with the shoulder at 90-degree flexion in males. There is a systematic difference in inter-rater results for all flexion positions and intra-rater results for one flexion position in males (p<0.05). MDC95% ranged from 3.44 to 11.69 for intra-rater scores and from 6.19 to10.79 for inter-rater scores.All procedures showed excellent reliability, except for moderate intra-rater reliability in seated measurement of elbow flexion strength with the shoulder at 90-degree flexion in males. However, elbow flexion measurement was prone to systematic differences in males. Muscle strength of the tested individual and testers should be considered.

手持式测力仪测量肘关节屈伸强度不同方案的可靠性。
研究通过手持式测力仪(HHD)在不同位置测量肘关节屈伸强度的可靠性,并确定最小可检测变化(MDC)。可靠性研究。在运动实验室对20名健康大学生进行了评估。肘关节屈曲和伸展强度分别由两名物理治疗师在三个不同的位置测量。计算类内相关系数(ICC)来评估评级内信度(ICC 3,3)和评级间信度(ICC 3,3),并用于计算MDC。所有测量方法在女性(0.88-0.98)和男性(0.81-0.95)中均具有优异的量表内信度和量表间信度评分,除了男性肩部90度屈曲时坐位测量肘关节屈曲强度的量表内信度为中等(0.72)。所有屈曲体位的评分结果和男性屈曲体位的评分结果存在系统性差异
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书