{"title":"Segmentation-model-based framework to detect aortic dissection on non-contrast CT images: a retrospective study.","authors":"Qidong Wang, Shan Huang, Weifeng Pan, Zhan Feng, Lei Lv, Dongwei Guan, Zhiwen Yang, Yimin Huang, Wei Liu, Weiwei Shui, Mingliang Ying, Wenbo Xiao","doi":"10.1186/s13244-025-02098-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To develop an automated deep learning framework for detecting aortic dissection (AD) and visualizing its morphology and extent on non-contrast CT (NCCT) images.</p><p><strong>Materials and methods: </strong>This retrospective study included patients who underwent aortic CTA from January 2021 to January 2023 at two tertiary hospitals. Demographic data, medical history, and CT scans were collected. A segmentation-based deep learning model was trained to identify true and false lumens on NCCT images, with performance evaluated on internal and external test sets. Segmentation accuracy was measured using the Dice coefficient, while the intraclass correlation coefficient (ICC) assessed consistency between predicted and ground-truth false lumen volumes. Receiver operating characteristic (ROC) analysis evaluated the model's predictive performance.</p><p><strong>Results: </strong>Among 701 patients (median age, 53 years, IQR: 41-64, 486 males), data from Center 1 were split into training (439 cases: 318 non-AD, 121 AD) and internal test sets (106 cases: 77 non-AD, 29 AD) (8:2 ratio), while Center 2 served as the external test set (156 cases: 80 non-AD, 76 AD). The ICC for false lumen volume was 0.823 (95% CI: 0.750-0.880) internally and 0.823 (95% CI: 0.760-0.870) externally. The model achieved an AUC of 0.935 (95% CI: 0.894-0.968) in the external test set, with an optimal cutoff of 7649 mm<sup>3</sup> yielding 88.2% sensitivity, 91.3% specificity, and 89.0% negative predictive value.</p><p><strong>Conclusions: </strong>The proposed deep learning framework accurately detects AD on NCCT and effectively visualizes its morphological features, demonstrating strong clinical potential.</p><p><strong>Critical relevance statement: </strong>This deep learning framework helps reduce the misdiagnosis of AD in emergencies with limited time. The satisfactory results of presenting true/false lumen on NCCT images benefit patients with contrast media contraindications and promote treatment decisions.</p><p><strong>Key points: </strong>False lumen volume was used as an indicator for AD. NCCT detects AD via this segmentation model. This framework enhances AD diagnosis in emergencies, reducing unnecessary contrast use.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"16 1","pages":"207"},"PeriodicalIF":4.5000,"publicationDate":"2025-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12463791/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-025-02098-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To develop an automated deep learning framework for detecting aortic dissection (AD) and visualizing its morphology and extent on non-contrast CT (NCCT) images.
Materials and methods: This retrospective study included patients who underwent aortic CTA from January 2021 to January 2023 at two tertiary hospitals. Demographic data, medical history, and CT scans were collected. A segmentation-based deep learning model was trained to identify true and false lumens on NCCT images, with performance evaluated on internal and external test sets. Segmentation accuracy was measured using the Dice coefficient, while the intraclass correlation coefficient (ICC) assessed consistency between predicted and ground-truth false lumen volumes. Receiver operating characteristic (ROC) analysis evaluated the model's predictive performance.
Results: Among 701 patients (median age, 53 years, IQR: 41-64, 486 males), data from Center 1 were split into training (439 cases: 318 non-AD, 121 AD) and internal test sets (106 cases: 77 non-AD, 29 AD) (8:2 ratio), while Center 2 served as the external test set (156 cases: 80 non-AD, 76 AD). The ICC for false lumen volume was 0.823 (95% CI: 0.750-0.880) internally and 0.823 (95% CI: 0.760-0.870) externally. The model achieved an AUC of 0.935 (95% CI: 0.894-0.968) in the external test set, with an optimal cutoff of 7649 mm3 yielding 88.2% sensitivity, 91.3% specificity, and 89.0% negative predictive value.
Conclusions: The proposed deep learning framework accurately detects AD on NCCT and effectively visualizes its morphological features, demonstrating strong clinical potential.
Critical relevance statement: This deep learning framework helps reduce the misdiagnosis of AD in emergencies with limited time. The satisfactory results of presenting true/false lumen on NCCT images benefit patients with contrast media contraindications and promote treatment decisions.
Key points: False lumen volume was used as an indicator for AD. NCCT detects AD via this segmentation model. This framework enhances AD diagnosis in emergencies, reducing unnecessary contrast use.
期刊介绍:
Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere!
I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe.
Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy.
A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field.
I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly.
The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members.
The journal went open access in 2012, which means that all articles published since then are freely available online.