BESS Assisted Off-Grid Wind Energy Conversion System Operated Under Adverse Battery-SoC Conditions

IF 4.5 2区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC
Sheshadri Shekhar Rauth;Debaprasad Kastha;Prabodh Bajpai
{"title":"BESS Assisted Off-Grid Wind Energy Conversion System Operated Under Adverse Battery-SoC Conditions","authors":"Sheshadri Shekhar Rauth;Debaprasad Kastha;Prabodh Bajpai","doi":"10.1109/TIA.2025.3578016","DOIUrl":null,"url":null,"abstract":"Wind Energy Conversion systems (WECS), supplying islanded microgrids, often incorporate a Battery Energy Storage System (BESS) as an energy-buffer. To ensure safety and long life, the battery-bank (BB) in such systems must not be overcharged or deep-discharged. This paper proposes a reconfigurable operational strategy for a doubly-fed induction generator (DFIG) based islanded WECS integrated with a BESS. When the <italic>State-of-Charge</i> (<italic>SoC</i>) of the BB approaches the maximum limit, the rotor side converter regulates the DC bus voltage using a modified voltage controller while operating the DFIG away from the Maximum Power Point. When the BB-<italic>SoC</i> approaches the minimum limit, a minimum consumer-discomfort factor based load-shedding strategy is proposed so that the BESS can regulate the DC-bus voltage without deep discharging the BB. The DFIG-BESS system supplying the benchmark CIGRE residential distribution network has been simulated in an Opal-RT real-time simulation environment. The proposed voltage controller shows 69.44% and 46.66% lower undershoot in the DFIG-stator active-power and 3.45% and 99.83% lower DC-voltage deviation compared to a PI-controller and latest literature, respectively, while transiting from the BESS to RSC based DC-bus voltage regulation. The proposed load-shedding strategy also reduces the DC-bus voltage dip significantly compared to a similar strategy proposed in the literature.","PeriodicalId":13337,"journal":{"name":"IEEE Transactions on Industry Applications","volume":"61 6","pages":"9640-9651"},"PeriodicalIF":4.5000,"publicationDate":"2025-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Industry Applications","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11028979/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Wind Energy Conversion systems (WECS), supplying islanded microgrids, often incorporate a Battery Energy Storage System (BESS) as an energy-buffer. To ensure safety and long life, the battery-bank (BB) in such systems must not be overcharged or deep-discharged. This paper proposes a reconfigurable operational strategy for a doubly-fed induction generator (DFIG) based islanded WECS integrated with a BESS. When the State-of-Charge (SoC) of the BB approaches the maximum limit, the rotor side converter regulates the DC bus voltage using a modified voltage controller while operating the DFIG away from the Maximum Power Point. When the BB-SoC approaches the minimum limit, a minimum consumer-discomfort factor based load-shedding strategy is proposed so that the BESS can regulate the DC-bus voltage without deep discharging the BB. The DFIG-BESS system supplying the benchmark CIGRE residential distribution network has been simulated in an Opal-RT real-time simulation environment. The proposed voltage controller shows 69.44% and 46.66% lower undershoot in the DFIG-stator active-power and 3.45% and 99.83% lower DC-voltage deviation compared to a PI-controller and latest literature, respectively, while transiting from the BESS to RSC based DC-bus voltage regulation. The proposed load-shedding strategy also reduces the DC-bus voltage dip significantly compared to a similar strategy proposed in the literature.
BESS辅助离网风能转换系统在不利的电池soc条件下运行
为孤岛微电网供电的风能转换系统(WECS)通常包含电池储能系统(BESS)作为能量缓冲。为确保安全性和长寿命,此类系统中的电池组(BB)不得过度充电或深度放电。提出了一种双馈感应发电机(DFIG)与BESS集成的孤岛WECS的可重构运行策略。当BB的充电状态(SoC)接近最大限制时,转子侧转换器使用修改的电压控制器调节直流母线电压,同时操作远离最大功率点的DFIG。当BB- soc接近最小极限时,提出了一种基于最小消费者不适因素的减载策略,使BESS能够在不深度放电BB的情况下调节直流母线电压。在Opal-RT实时仿真环境中,对提供CIGRE住宅配电网基准的DFIG-BESS系统进行了仿真。与pi控制器和最新文献相比,该电压控制器在从BESS过渡到基于RSC的直流母线电压调节时,dfig1 -定子有功功率的欠冲降低了69.44%和46.66%,直流电压偏差降低了3.45%和99.83%。与文献中提出的类似策略相比,所提出的减载策略还显著降低了直流母线电压降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Industry Applications
IEEE Transactions on Industry Applications 工程技术-工程:电子与电气
CiteScore
9.90
自引率
9.10%
发文量
747
审稿时长
3.3 months
期刊介绍: The scope of the IEEE Transactions on Industry Applications includes all scope items of the IEEE Industry Applications Society, that is, the advancement of the theory and practice of electrical and electronic engineering in the development, design, manufacture, and application of electrical systems, apparatus, devices, and controls to the processes and equipment of industry and commerce; the promotion of safe, reliable, and economic installations; industry leadership in energy conservation and environmental, health, and safety issues; the creation of voluntary engineering standards and recommended practices; and the professional development of its membership.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信