Exploratory continuous interstitial glucose monitoring using the FreeStyle Libre 2 device in cynomolgus monkeys

IF 1.8 4区 医学 Q4 PHARMACOLOGY & PHARMACY
Julia Popp , Cassandra O'Hara , J.E. Bernal , Jackson Kalanzi , Mariusz Lubomirski , Dina Andrews-Cleavenger , J. Karmel , K.A. Henderson
{"title":"Exploratory continuous interstitial glucose monitoring using the FreeStyle Libre 2 device in cynomolgus monkeys","authors":"Julia Popp ,&nbsp;Cassandra O'Hara ,&nbsp;J.E. Bernal ,&nbsp;Jackson Kalanzi ,&nbsp;Mariusz Lubomirski ,&nbsp;Dina Andrews-Cleavenger ,&nbsp;J. Karmel ,&nbsp;K.A. Henderson","doi":"10.1016/j.vascn.2025.107776","DOIUrl":null,"url":null,"abstract":"<div><div>Glucose is an important endpoint in efficacy and toxicology assessments for cardiometabolic indications. Collection of serial glucose values can inform treatment-related effects and animal health status. Handling stress can cause heart rate (HR) and glucose spikes in nonhuman primates (NHPs), increasing variability and confounding data interpretation. Continuous glucose monitors (CGMs) are sensor-based systems that provide interstitial glucose (IG) readings without venipuncture; thus reducing handling stress and resultant glucose spikes. The purpose of this study was to evaluate the Freestyle®Libre™2 CGM (FL2-CGMs, Abbott) with NHPs for multiple days with simultaneous continuous HR monitoring and collection of serum to determine glucose and insulin levels at key timepoints. FL2-CGMs were pericutaneously applied to the back of jacketed NHPs for IG measurements. FL2-CGMs retain up to 8 h of data in 15 min increments. IG data were collected at 10 h intervals for 72 h after each dose administration. During phase 1, jacketed external telemetry was used for assessment of concurrent HR over 24 h. Animals were administered saline, oral glucose (1 g/kg) or injections of 0.15 U/kg insulin. Serum glucose and insulin were measured to compare with IG data predose, 8, and 24 h postdose. In phase 2, animals were administered 3 g/kg glucose; IG was monitored over 72 h with repeated serum sampling of glucose and insulin within the first 8 h of data collection to compare magnitude and timing of changes between the two glucose collection methods. Higher IG levels (up to 72 mg/dL above predose levels) were observed with FL2-CGMs in response to 3 g/kg glucose, while changes in IG levels in response to 1 g/kg glucose were not reliably detected outside of observed IG variability. FL2-CGM captured lower glucose levels (12 mg/dL below controls) after administration of 0.15 U/kg insulin. HR spikes due to handling were concurrent with increased glucose (IG and serum) and serum insulin. In conclusion, this investigation demonstrates that FL2-CGMs can be successfully used for characterization of continuous glucose levels in NHPs and provides a significant advantage over glucose measured from serum samples collected from restrained animals.</div></div>","PeriodicalId":16767,"journal":{"name":"Journal of pharmacological and toxicological methods","volume":"135 ","pages":"Article 107776"},"PeriodicalIF":1.8000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological and toxicological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1056871925001960","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Glucose is an important endpoint in efficacy and toxicology assessments for cardiometabolic indications. Collection of serial glucose values can inform treatment-related effects and animal health status. Handling stress can cause heart rate (HR) and glucose spikes in nonhuman primates (NHPs), increasing variability and confounding data interpretation. Continuous glucose monitors (CGMs) are sensor-based systems that provide interstitial glucose (IG) readings without venipuncture; thus reducing handling stress and resultant glucose spikes. The purpose of this study was to evaluate the Freestyle®Libre™2 CGM (FL2-CGMs, Abbott) with NHPs for multiple days with simultaneous continuous HR monitoring and collection of serum to determine glucose and insulin levels at key timepoints. FL2-CGMs were pericutaneously applied to the back of jacketed NHPs for IG measurements. FL2-CGMs retain up to 8 h of data in 15 min increments. IG data were collected at 10 h intervals for 72 h after each dose administration. During phase 1, jacketed external telemetry was used for assessment of concurrent HR over 24 h. Animals were administered saline, oral glucose (1 g/kg) or injections of 0.15 U/kg insulin. Serum glucose and insulin were measured to compare with IG data predose, 8, and 24 h postdose. In phase 2, animals were administered 3 g/kg glucose; IG was monitored over 72 h with repeated serum sampling of glucose and insulin within the first 8 h of data collection to compare magnitude and timing of changes between the two glucose collection methods. Higher IG levels (up to 72 mg/dL above predose levels) were observed with FL2-CGMs in response to 3 g/kg glucose, while changes in IG levels in response to 1 g/kg glucose were not reliably detected outside of observed IG variability. FL2-CGM captured lower glucose levels (12 mg/dL below controls) after administration of 0.15 U/kg insulin. HR spikes due to handling were concurrent with increased glucose (IG and serum) and serum insulin. In conclusion, this investigation demonstrates that FL2-CGMs can be successfully used for characterization of continuous glucose levels in NHPs and provides a significant advantage over glucose measured from serum samples collected from restrained animals.
使用FreeStyle Libre 2设备对食蟹猴间质葡萄糖进行探索性连续监测
葡萄糖是心脏代谢适应症疗效和毒理学评估的重要终点。一系列葡萄糖值的收集可以告知治疗相关效果和动物健康状况。处理压力会导致非人类灵长类动物(NHPs)的心率(HR)和葡萄糖峰值,增加可变性并混淆数据解释。连续血糖监测仪(cgm)是一种基于传感器的系统,可以在没有静脉穿刺的情况下提供间质血糖(IG)读数;从而减少处理压力和由此产生的葡萄糖峰值。本研究的目的是对使用NHPs的Freestyle®Libre™2 CGM (fl2 -CGM,雅培)进行为期多天的评估,同时进行持续的HR监测和血清收集,以确定关键时间点的葡萄糖和胰岛素水平。将fl2 - cgm经皮应用于夹套NHPs的背部进行IG测量。FL2-CGMs以15 min的增量保留高达8 h的数据。IG数据在每次给药后每隔10 h收集72 h。在第一阶段,使用夹套外部遥测技术评估24 h以上的并发HR。分别给予生理盐水、口服葡萄糖(1 g/kg)或注射胰岛素(0.15 U/kg)。在给药前、给药后8和24 h,测定血清葡萄糖和胰岛素与IG数据进行比较。在第二阶段,动物被给予3 g/kg葡萄糖;在72 h内监测IG,在数据收集的前8 h内反复抽取血清葡萄糖和胰岛素,以比较两种葡萄糖收集方法的变化幅度和时间。当葡萄糖浓度为3 g/kg时,fl2 - cgm的IG水平升高(高于给药前水平72 mg/dL),而在葡萄糖浓度为1 g/kg时,IG水平的变化在观察到的IG变变性之外无法可靠地检测到。在给药0.15 U/kg胰岛素后,FL2-CGM捕获到较低的葡萄糖水平(比对照组低12 mg/dL)。处理引起的HR峰值与葡萄糖(IG和血清)和血清胰岛素升高同时发生。总之,本研究表明fl2 - cgm可以成功地用于表征NHPs中的连续葡萄糖水平,并且比从受限动物的血清样本中测量葡萄糖具有显着优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of pharmacological and toxicological methods
Journal of pharmacological and toxicological methods PHARMACOLOGY & PHARMACY-TOXICOLOGY
CiteScore
3.60
自引率
10.50%
发文量
56
审稿时长
26 days
期刊介绍: Journal of Pharmacological and Toxicological Methods publishes original articles on current methods of investigation used in pharmacology and toxicology. Pharmacology and toxicology are defined in the broadest sense, referring to actions of drugs and chemicals on all living systems. With its international editorial board and noted contributors, Journal of Pharmacological and Toxicological Methods is the leading journal devoted exclusively to experimental procedures used by pharmacologists and toxicologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信