Johan Sundström, Anton Finnson, Elin Hynning, Geert De Kerf, Albin Fredriksson
{"title":"Partitioning of multiple brain metastases improves dose gradients in single-isocenter radiosurgery","authors":"Johan Sundström, Anton Finnson, Elin Hynning, Geert De Kerf, Albin Fredriksson","doi":"10.1002/mp.18117","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>A growing number of cancer patients with brain metastases can benefit from stereotactic radiosurgery (SRS) thanks to recent advances in systemic therapies which have led to improved survival. Meanwhile, selection criteria for SRS treatments are evolving to include patients with increasingly many metastases. With an increasing patient load, single-isocenter treatments on widely available C-arm linear accelerators are an attractive option. However, the planning of such treatments is challenging for multi-target cases due to the island blocking problem, which occurs when the multi-leaf collimator cannot conform to all targets simultaneously.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>We propose a multi-target partitioning algorithm that mitigates excessive exposure of normal tissue caused by the island blocking problem.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The proposed algorithm considers an initial set of arc trajectories and divides (partitions) the set of targets per trajectory into smaller subsets to treat with separate back-and-forth arc passes, simultaneously optimizing both the target subsets and collimator angles to minimize island blocking. We incorporated this algorithm into a fully automated treatment planning script and evaluated it on 20 simulated patient cases, each with 10 brain metastases and 21 Gy prescriptions. For each case, the script generated a series of volumetric modulated arc therapy (VMAT) plans with increasingly many arcs along the three trajectories. Each such plan was compared to four baseline plans generated with alternative heuristics for distributing targets across arcs. We also evaluated the algorithm retrospectively on six clinical cases.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Partitioning significantly improved the gradient index (GI), global efficiency index (<span></span><math>\n <semantics>\n <mrow>\n <mi>G</mi>\n <mi>η</mi>\n </mrow>\n <annotation>${\\rm G}\\eta$</annotation>\n </semantics></math>) and brain <span></span><math>\n <semantics>\n <msub>\n <mi>V</mi>\n <mrow>\n <mn>12</mn>\n <mspace></mspace>\n <mi>Gy</mi>\n </mrow>\n </msub>\n <annotation>$\\text{V}_{12\\nobreakspace \\mathrm{Gy}}$</annotation>\n </semantics></math> compared to simultaneous treatment of all metastases. For example, the average GI improved from 5.9 to 3.3, <span></span><math>\n <semantics>\n <mrow>\n <mi>G</mi>\n <mi>η</mi>\n </mrow>\n <annotation>${\\rm G}\\eta$</annotation>\n </semantics></math> from 0.32 to 0.46, and normal brain <span></span><math>\n <semantics>\n <msub>\n <mi>V</mi>\n <mrow>\n <mn>12</mn>\n <mspace></mspace>\n <mi>Gy</mi>\n </mrow>\n </msub>\n <annotation>$\\text{V}_{12\\nobreakspace \\mathrm{Gy}}$</annotation>\n </semantics></math> from 49 <span></span><math>\n <semantics>\n <mrow>\n <mspace></mspace>\n <mi>c</mi>\n <msup>\n <mi>m</mi>\n <mn>3</mn>\n </msup>\n <mspace></mspace>\n </mrow>\n <annotation>$\\,\\mathrm{c}\\mathrm{m}^{3}\\,$</annotation>\n </semantics></math> to 26 <span></span><math>\n <semantics>\n <mrow>\n <mspace></mspace>\n <mi>c</mi>\n <msup>\n <mi>m</mi>\n <mn>3</mn>\n </msup>\n <mspace></mspace>\n </mrow>\n <annotation>$\\,\\mathrm{c}\\mathrm{m}^{3}\\,$</annotation>\n </semantics></math> between 3 and 9 arcs. The baseline plans improved similarly, but the proposed algorithm was significantly better at utilizing a limited budget of arcs. All target partitioning strategies increased the total number of monitor units (MUs).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The dose gradient in single-isocenter VMAT plans can be substantially improved by treating a smaller subset of metastases at a time. This requires more MUs and arcs, implying a trade-off between delivery time and plan quality, which can be explored using the algorithm proposed in this paper.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"52 10","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.18117","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background
A growing number of cancer patients with brain metastases can benefit from stereotactic radiosurgery (SRS) thanks to recent advances in systemic therapies which have led to improved survival. Meanwhile, selection criteria for SRS treatments are evolving to include patients with increasingly many metastases. With an increasing patient load, single-isocenter treatments on widely available C-arm linear accelerators are an attractive option. However, the planning of such treatments is challenging for multi-target cases due to the island blocking problem, which occurs when the multi-leaf collimator cannot conform to all targets simultaneously.
Purpose
We propose a multi-target partitioning algorithm that mitigates excessive exposure of normal tissue caused by the island blocking problem.
Methods
The proposed algorithm considers an initial set of arc trajectories and divides (partitions) the set of targets per trajectory into smaller subsets to treat with separate back-and-forth arc passes, simultaneously optimizing both the target subsets and collimator angles to minimize island blocking. We incorporated this algorithm into a fully automated treatment planning script and evaluated it on 20 simulated patient cases, each with 10 brain metastases and 21 Gy prescriptions. For each case, the script generated a series of volumetric modulated arc therapy (VMAT) plans with increasingly many arcs along the three trajectories. Each such plan was compared to four baseline plans generated with alternative heuristics for distributing targets across arcs. We also evaluated the algorithm retrospectively on six clinical cases.
Results
Partitioning significantly improved the gradient index (GI), global efficiency index () and brain compared to simultaneous treatment of all metastases. For example, the average GI improved from 5.9 to 3.3, from 0.32 to 0.46, and normal brain from 49 to 26 between 3 and 9 arcs. The baseline plans improved similarly, but the proposed algorithm was significantly better at utilizing a limited budget of arcs. All target partitioning strategies increased the total number of monitor units (MUs).
Conclusions
The dose gradient in single-isocenter VMAT plans can be substantially improved by treating a smaller subset of metastases at a time. This requires more MUs and arcs, implying a trade-off between delivery time and plan quality, which can be explored using the algorithm proposed in this paper.
期刊介绍:
Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments
Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.