Buttress Plating for Type 3-4-5 Jersey Finger Fractures: Without Bone Fragment Disruption and With a Challenging Rate of Hardware Removal-A Case Series.

IF 2.1 2区 医学 Q2 ORTHOPEDICS
Ömer F Kümbüloğlu, Yusuf Altuntas, İsmail Demirkale
{"title":"Buttress Plating for Type 3-4-5 Jersey Finger Fractures: Without Bone Fragment Disruption and With a Challenging Rate of Hardware Removal-A Case Series.","authors":"Ömer F Kümbüloğlu, Yusuf Altuntas, İsmail Demirkale","doi":"10.1016/j.jhsa.2025.07.038","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The use of plates in the treatment of Leddy-Packer type 3-5 flexor digitorum profundus tendon avulsion injuries is becoming increasingly prevalent; however, potential complications, including disruption of the avulsed bone fragment and damage to the flexor digitorum profundus tendon, may be encountered. The objective of this study was to ascertain whether the buttress plate technique, without screw placement in the avulsed fragment, can be employed as a treatment option for patients with type 3, 4, and 5 flexor digitorum profundus tendon avulsion injuries.</p><p><strong>Methods: </strong>Type 3, 4, and 5 flexor digitorum profundus tendon avulsion injuries treated with the buttress plate technique were evaluated retrospectively. The Disabilities of the Arm, Shoulder, and Hand score, range of motion of the distal interphalangeal joint, and visual analog scale score for pain were assessed.</p><p><strong>Results: </strong>The study included 12 patients with types 3-5 flexor digitorum profundus tendon avulsion injury. The follow-up period averaged 21 months (range, 15-32 months). All patients achieved union. The mean active range of flexion motion obtained in the distal interphalangeal joint was 74° (SD, 19°). Patients with type 3 and 5 injuries exhibited a functional distal interphalangeal joint range of motion. The plate was removed in nine patients with plate-related tenderness in the finger.</p><p><strong>Conclusions: </strong>The buttress plate technique may be considered as a treatment option for type 3 and type 5 injuries.</p><p><strong>Type of study/level of evidence: </strong>Therapeutic IV.</p>","PeriodicalId":54815,"journal":{"name":"Journal of Hand Surgery-American Volume","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-American Volume","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jhsa.2025.07.038","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The use of plates in the treatment of Leddy-Packer type 3-5 flexor digitorum profundus tendon avulsion injuries is becoming increasingly prevalent; however, potential complications, including disruption of the avulsed bone fragment and damage to the flexor digitorum profundus tendon, may be encountered. The objective of this study was to ascertain whether the buttress plate technique, without screw placement in the avulsed fragment, can be employed as a treatment option for patients with type 3, 4, and 5 flexor digitorum profundus tendon avulsion injuries.

Methods: Type 3, 4, and 5 flexor digitorum profundus tendon avulsion injuries treated with the buttress plate technique were evaluated retrospectively. The Disabilities of the Arm, Shoulder, and Hand score, range of motion of the distal interphalangeal joint, and visual analog scale score for pain were assessed.

Results: The study included 12 patients with types 3-5 flexor digitorum profundus tendon avulsion injury. The follow-up period averaged 21 months (range, 15-32 months). All patients achieved union. The mean active range of flexion motion obtained in the distal interphalangeal joint was 74° (SD, 19°). Patients with type 3 and 5 injuries exhibited a functional distal interphalangeal joint range of motion. The plate was removed in nine patients with plate-related tenderness in the finger.

Conclusions: The buttress plate technique may be considered as a treatment option for type 3 and type 5 injuries.

Type of study/level of evidence: Therapeutic IV.

支撑钢板治疗3-4-5型泽西手指骨折:无骨碎片断裂和具有挑战性的硬件移除率-病例系列
目的:钢板在Leddy-Packer 3-5型指深屈肌腱撕脱伤治疗中的应用越来越普遍;然而,可能会遇到潜在的并发症,包括撕脱骨碎片的破坏和指深屈肌腱的损伤。本研究的目的是确定在撕脱碎片中不放置螺钉的支撑板技术是否可以作为3、4、5型指深屈肌腱撕脱伤患者的治疗选择。方法:回顾性评价支板技术治疗3、4、5型指深屈肌腱撕脱伤的疗效。评估手臂、肩和手的残疾评分、远端指间关节的活动范围和疼痛的视觉模拟评分。结果:本研究纳入12例3-5型指深屈肌腱撕脱伤。随访时间平均为21个月(15 ~ 32个月)。所有患者均愈合。远端指间关节的平均屈曲活动范围为74°(SD, 19°)。3型和5型损伤患者表现出功能性远端指间关节活动范围。9例手指有钢板相关压痛的患者取下了钢板。结论:支板技术可作为3型和5型损伤的治疗选择。研究类型/证据水平:治疗性IV。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.20
自引率
10.50%
发文量
402
审稿时长
12 weeks
期刊介绍: The Journal of Hand Surgery publishes original, peer-reviewed articles related to the pathophysiology, diagnosis, and treatment of diseases and conditions of the upper extremity; these include both clinical and basic science studies, along with case reports. Special features include Review Articles (including Current Concepts and The Hand Surgery Landscape), Reviews of Books and Media, and Letters to the Editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信