Diagnostic Evaluation of Automatic Noncontact Ultra-Wideband Radar Combined With Oximeter for Obstructive Sleep Apnea in the South of China.

IF 2.1 4区 医学 Q3 RESPIRATORY SYSTEM
Canadian respiratory journal Pub Date : 2025-09-03 eCollection Date: 2025-01-01 DOI:10.1155/carj/6631384
Shuyue Wang, Jian Wu, Haiyao Zheng, Yan Ruan, Feng Yu, Tao Liao
{"title":"Diagnostic Evaluation of Automatic Noncontact Ultra-Wideband Radar Combined With Oximeter for Obstructive Sleep Apnea in the South of China.","authors":"Shuyue Wang, Jian Wu, Haiyao Zheng, Yan Ruan, Feng Yu, Tao Liao","doi":"10.1155/carj/6631384","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Polysomnography (PSG) is the traditional technique for diagnosing obstructive sleep apnea (OSA) with some limitations. Ultra-wideband radar (UWB) is a new method for diagnosing OSA that combines multiple techniques including radar technology, artificial intelligence (AI), and big data algorithms. The accuracy of UWB in OSA diagnosis needs further scientific verification, especially in southern China. <b>Methods:</b> Fifty patients from southern China wore UWB with oximetry and PSG simultaneously overnight. UWB generated automated reports; PSG was manually interpreted. Lowest oxygen saturation (LSpO2) and apnea-hypopnea index (AHI) from both methods were compared. <b>Results:</b> High correlation was found between UWB and PSG for AHI (<i>r</i> = 0.925, <i>p</i> < 0.001) and LSpO2 (<i>r</i> = 0.990, <i>p</i> < 0.001). The average bias of AHI (-3.09, <i>p</i>=0.98, 95% CI -15.48 - 9.31) and LSpO2 (-0.34, <i>p</i> > 0.99, 95% CI -3.68 - 3.04) between the two methods was small. ROC analysis showed good diagnostic performance of UWB versus PSG (AUC = 0.979, <i>p</i> < 0.001), with 95.8% sensitivity and 100% specificity. <b>Conclusion:</b> The study demonstrated UWB combined with oximetry could be a reliable alternative to PSG for diagnosing OSA in the south of China.</p>","PeriodicalId":9416,"journal":{"name":"Canadian respiratory journal","volume":"2025 ","pages":"6631384"},"PeriodicalIF":2.1000,"publicationDate":"2025-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12422862/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian respiratory journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/carj/6631384","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Polysomnography (PSG) is the traditional technique for diagnosing obstructive sleep apnea (OSA) with some limitations. Ultra-wideband radar (UWB) is a new method for diagnosing OSA that combines multiple techniques including radar technology, artificial intelligence (AI), and big data algorithms. The accuracy of UWB in OSA diagnosis needs further scientific verification, especially in southern China. Methods: Fifty patients from southern China wore UWB with oximetry and PSG simultaneously overnight. UWB generated automated reports; PSG was manually interpreted. Lowest oxygen saturation (LSpO2) and apnea-hypopnea index (AHI) from both methods were compared. Results: High correlation was found between UWB and PSG for AHI (r = 0.925, p < 0.001) and LSpO2 (r = 0.990, p < 0.001). The average bias of AHI (-3.09, p=0.98, 95% CI -15.48 - 9.31) and LSpO2 (-0.34, p > 0.99, 95% CI -3.68 - 3.04) between the two methods was small. ROC analysis showed good diagnostic performance of UWB versus PSG (AUC = 0.979, p < 0.001), with 95.8% sensitivity and 100% specificity. Conclusion: The study demonstrated UWB combined with oximetry could be a reliable alternative to PSG for diagnosing OSA in the south of China.

Abstract Image

Abstract Image

Abstract Image

自动非接触式超宽带雷达联合血氧仪对南方地区阻塞性睡眠呼吸暂停的诊断评价。
背景:多导睡眠图(PSG)是诊断阻塞性睡眠呼吸暂停(OSA)的传统方法,但存在一定的局限性。超宽带雷达(UWB)是结合雷达技术、人工智能(AI)、大数据算法等多种技术的OSA诊断新方法。超宽带在OSA诊断中的准确性有待进一步的科学验证,尤其是在中国南方地区。方法:50例华南地区患者夜间同时佩戴UWB血氧仪和PSG。UWB生成自动报告;PSG是手动解释的。比较两种方法的最低血氧饱和度(LSpO2)和呼吸暂停低通气指数(AHI)。结果:UWB与PSG对AHI (r = 0.925, p < 0.001)、LSpO2 (r = 0.990, p < 0.001)有高度相关性。两种方法的AHI (-3.09, p=0.98, 95% CI -15.48 ~ 9.31)和LSpO2 (-0.34, p= 0.99, 95% CI -3.68 ~ 3.04)的平均偏倚较小。ROC分析显示UWB与PSG的诊断效果较好(AUC = 0.979, p < 0.001),敏感性95.8%,特异性100%。结论:UWB联合血氧测定在中国南方地区可作为诊断OSA的可靠替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Canadian respiratory journal
Canadian respiratory journal 医学-呼吸系统
CiteScore
4.20
自引率
0.00%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Canadian Respiratory Journal is a peer-reviewed, Open Access journal that aims to provide a multidisciplinary forum for research in all areas of respiratory medicine. The journal publishes original research articles, review articles, and clinical studies related to asthma, allergy, COPD, non-invasive ventilation, therapeutic intervention, lung cancer, airway and lung infections, as well as any other respiratory diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信