Effect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation.

IF 3.8 Q2 ORTHOPEDICS
JBJS Open Access Pub Date : 2025-09-08 eCollection Date: 2025-07-01 DOI:10.2106/JBJS.OA.25.00182
Jason Brant, Michael Roberts, Nathaniel Nelms, Patrick Schottel, Mark Haimes, Michael Blankstein
{"title":"Effect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation.","authors":"Jason Brant, Michael Roberts, Nathaniel Nelms, Patrick Schottel, Mark Haimes, Michael Blankstein","doi":"10.2106/JBJS.OA.25.00182","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle.</p><p><strong>Methods: </strong>This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes.</p><p><strong>Results: </strong>A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001).</p><p><strong>Conclusions: </strong>There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation.</p><p><strong>Level of evidence: </strong>Level IV. See Instructions for Authors for a complete description of levels of evidence.</p>","PeriodicalId":36492,"journal":{"name":"JBJS Open Access","volume":"10 3","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12412743/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBJS Open Access","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2106/JBJS.OA.25.00182","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle.

Methods: This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes.

Results: A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001).

Conclusions: There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation.

Level of evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.

Abstract Image

Abstract Image

Abstract Image

机器人辅助全膝关节置换术中股骨假体屈曲对逆行髓内钉矢状轨迹角度的影响。
背景:在机器人辅助全膝关节置换术(RA-TKA)中,股骨假体的定位独立于髓内管,并且经常处于屈曲状态以优化功能。股骨假体屈曲移位后侧逆行髓内钉(rIMN)起始点可能加剧假体周围骨折(PPFx)固定时的过伸畸形。本研究的目的是确定RA-TKA股骨假体屈曲与rIMN矢状轨迹成角之间的关系。我们假设股骨组成部分的屈曲增加了甲矢状角。方法:这是一项单中心学术观察性研究,纳入了2023年8月至2024年2月期间由3名接受过奖学金培训的关节置换外科医生进行原发性RA-TKA的成年患者。通过术中计算机断层扫描截图获得膝关节间隙平衡后股骨植入物的最终特征。使用ImageJ软件测量基于远端股钉起始点和股轴中心的rIMN轨迹矢状角,并与几个变量进行比较,重点关注10 mm和12 mm钉尺寸的股假体屈曲。结果:共纳入111例患者,其中女性61例,男性50例,平均年龄67岁(SD 10),身高168 cm (SD 11)。10-mm和12-mm的平均股骨假体屈曲度分别为5.87°(SD 2.13)和9.83°(SD 2.79)和11.43°(SD 2.88)。对于两种指甲尺寸,股骨假体屈曲度每增加1.0°,平均矢状角增加0.50°具有显著的线性相关性(p < 0.001)。结论:股骨假体屈曲与rIMN矢状位轨迹角呈线性相关。平均矢状角度约为10°,平均构件屈曲为6°。随着全国范围内ra - tka手术数量的增加,可以考虑采用带远端弯曲的rIMN来补偿股骨假体屈曲,以限制股骨远端PPFx固定时的过伸畸形。证据等级:IV级。参见《作者说明》获得证据等级的完整描述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JBJS Open Access
JBJS Open Access Medicine-Surgery
CiteScore
5.00
自引率
0.00%
发文量
77
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信